Literature DB >> 12075685

Patient effective radiation dose and associated risk from transmission scans using 153Gd line sources in cardiac spect studies.

Kostas Perisinakis1, Nicholas Theocharopoulos, Nicholas Karkavitsas, John Damilakis.   

Abstract

The aim of the present study was to determine the contribution of transmission measurements acquisition to total patient effective dose from cardiac SPECT studies. A dual-head L-shaped gamma camera equipped with a transmission scan acquisition system based on two 153Gd line sources was used to simulate transmission measurements acquisition exposure on an anthropomorphic phantom. Thermoluminescence dosimeters were used to directly monitor the dose to 550 measuring points in the phantom. The effective dose and associated risk from transmission scans acquisition were estimated and compared to those associated to the radiopharmaceutical injected. The maximum effective dose from a typical transmission measurements acquisition was 1.3 microSv and 1.9 microSv for male and female patients, respectively. The contribution of the typical transmission scans acquisition to total patient radiation risk from a cardiac SPECT study is less than 10(-3). Thus, radiation exposure may not be considered as a limiting factor for the clinical application of attenuation correction methods based on transmission measurements in cardiac SPECT.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12075685     DOI: 10.1097/00004032-200207000-00007

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  9 in total

1.  Patient-centered imaging.

Authors:  E Gordon Depuey; John J Mahmarian; Todd D Miller; Andrew J Einstein; Christopher L Hansen; Thomas A Holly; Edward J Miller; Donna M Polk; L Samuel Wann
Journal:  J Nucl Cardiol       Date:  2012-04       Impact factor: 5.952

2.  Radiation dose and risk from fluoroscopically guided percutaneous transluminal angioplasty and stenting in the abdominal region.

Authors:  John Stratakis; John Damilakis; Dimitrios Tsetis; Nicholas Gourtsoyiannis
Journal:  Eur Radiol       Date:  2007-03-27       Impact factor: 5.315

3.  Minimizing the radiation dose of CT attenuation correction while improving image quality: The case for innovation.

Authors:  James A Case
Journal:  J Nucl Cardiol       Date:  2015-06-23       Impact factor: 5.952

4.  Contemporary Cardiac SPECT Imaging-Innovations and Best Practices: An Information Statement from the American Society of Nuclear Cardiology.

Authors:  Brian G Abbott; James A Case; Sharmila Dorbala; Andrew J Einstein; James R Galt; Robert Pagnanelli; Renée P Bullock-Palmer; Prem Soman; R Glenn Wells
Journal:  J Nucl Cardiol       Date:  2018-10       Impact factor: 5.952

5.  Radiogenic risks from hysterosalpingography.

Authors:  Kostas Perisinakis; John Damilakis; John Grammatikakis; Nicholas Theocharopoulos; Nicholas Gourtsoyiannis
Journal:  Eur Radiol       Date:  2003-02-11       Impact factor: 5.315

6.  Radiation reduction with prospective ECG-triggering acquisition using 64-multidetector Computed Tomographic angiography.

Authors:  Ambarish Gopal; Song S Mao; Daniel Karlsberg; Emily Young; Joshua Waggoner; Naser Ahmadi; Raveen S Pal; John Leal; Ronald P Karlsberg; Matthew J Budoff
Journal:  Int J Cardiovasc Imaging       Date:  2008-12-03       Impact factor: 2.357

7.  Optimisation of protocol for low dose CT-derived attenuation correction in myocardial perfusion SPECT imaging.

Authors:  Rainer Preuss; Reiner Weise; Oliver Lindner; Eva Fricke; Harald Fricke; Wolfgang Burchert
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-01-12       Impact factor: 9.236

8.  Comprehensive assessment of myocardial perfusion defects, regional wall motion, and left ventricular function by using 64-section multidetector CT.

Authors:  Ricardo C Cury; Koen Nieman; Michael D Shapiro; Javed Butler; Cesar H Nomura; Maros Ferencik; Udo Hoffmann; Suhny Abbara; Davinder S Jassal; Tsunehiro Yasuda; Herman K Gold; Ik-Kyung Jang; Thomas J Brady
Journal:  Radiology       Date:  2008-08       Impact factor: 11.105

9.  Pediatric radiation dose and risk from bone density measurements using a GE Lunar Prodigy scanner.

Authors:  J Damilakis; G Solomou; G E Manios; A Karantanas
Journal:  Osteoporos Int       Date:  2013-01-10       Impact factor: 4.507

  9 in total