Literature DB >> 12063232

Three-dimensional, T1-weighted gradient-echo imaging of the brain with a volumetric interpolated examination.

Stephan G Wetzel1, Glyn Johnson, Andrew G S Tan, Soonmee Cha, Edmond A Knopp, Vivian S Lee, David Thomasson, Neil M Rofsky.   

Abstract

BACKGROUND AND
PURPOSE: T1-weighted, 3D gradient-echo MR sequences can be optimized for rapid acquisition and improved resolution through asymmetric k-space sampling and interpolation. We compared a volumetric interpolated brain examination (VIBE) sequence with a magnetization-prepared rapid acquisition gradient echo (MP RAGE) sequence and a 2D T1-weighted spin-echo (SE) sequence.
METHODS: Thirty consecutive patients known or suspected to have focal brain lesions underwent postcontrast studies (20 mL of gadopentetate dimeglumine) with VIBE, MP RAGE, and 2D T1-weighted SE imaging. Source and 5-mm VIBE and MP RAGE reformations, and 5-mm T1-weighted SE images were compared qualitatively and by using signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). SNRs in a gadolinium-doped water phantom were also measured for all three sequences.
RESULTS: On the source images, SNRs for gray matter (GM) and white matter (WM), and CNRs for WM-to-GM and contrast-enhancing lesion-to-GM were slightly, but significantly higher for the VIBE sequence than for the MP RAGE sequence (P <.05). On 5-mm reformations, WM-to-GM CNR was significantly higher on VIBE and MP RAGE images than on T1-weighted SE images (P <.001), but contrast-enhancing lesion-to-GM CNRs were higher on SE images compared with both gradient-echo sequences (P <.001). Qualitatively, VIBE images showed fewer flow artifacts than did SE and MP RAGE images (P <.05). In the phantom, VIBE SNR was higher than MP RAGE SNR for short T1 relaxation times.
CONCLUSION: VIBE provides an effective, alternative approach to MP RAGE for fast 3D T1-weighted imaging of the brain.

Entities:  

Mesh:

Year:  2002        PMID: 12063232      PMCID: PMC7976903     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  21 in total

1.  Optimization of 3-D MP-RAGE sequences for structural brain imaging.

Authors:  R Deichmann; C D Good; O Josephs; J Ashburner; R Turner
Journal:  Neuroimage       Date:  2000-07       Impact factor: 6.556

2.  2D multislice and 3D MRI sequences are often equally sensitive.

Authors:  G Johnson; Y Z Wadghiri; D H Turnbull
Journal:  Magn Reson Med       Date:  1999-04       Impact factor: 4.668

3.  Signal-to-noise, resolution, and bias function analysis of asymmetric sampling with zero-padded magnitude FT reconstruction.

Authors:  G C Hurst; J Hua; O P Simonetti; J L Duerk
Journal:  Magn Reson Med       Date:  1992-10       Impact factor: 4.668

4.  MP RAGE: a three-dimensional, T1-weighted, gradient-echo sequence--initial experience in the brain.

Authors:  M Brant-Zawadzki; G D Gillan; W R Nitz
Journal:  Radiology       Date:  1992-03       Impact factor: 11.105

5.  Three-dimensional magnetization-prepared rapid gradient-echo imaging (3D MP RAGE).

Authors:  J P Mugler; J R Brookeman
Journal:  Magn Reson Med       Date:  1990-07       Impact factor: 4.668

6.  Clinical usefulness of contrast-enhanced MP-RAGE of the brain.

Authors:  L van den Hauwe; P M Parizel; J W Van Goethem; A M De Schepper
Journal:  Neuroradiology       Date:  1996-05       Impact factor: 2.804

7.  Contrast in rapid MR imaging: T1- and T2-weighted imaging.

Authors:  R B Buxton; R R Edelman; B R Rosen; G L Wismer; T J Brady
Journal:  J Comput Assist Tomogr       Date:  1987 Jan-Feb       Impact factor: 1.826

8.  Abdominal MR imaging with a volumetric interpolated breath-hold examination.

Authors:  N M Rofsky; V S Lee; G Laub; M A Pollack; G A Krinsky; D Thomasson; M M Ambrosino; J C Weinreb
Journal:  Radiology       Date:  1999-09       Impact factor: 11.105

9.  Theoretical analysis of gadopentetate dimeglumine enhancement in T1-weighted imaging of the brain: comparison of two-dimensional spin-echo and three-dimensional gradient-echo sequences.

Authors:  J P Mugler; J R Brookeman
Journal:  J Magn Reson Imaging       Date:  1993 Sep-Oct       Impact factor: 4.813

10.  The effect of paramagnetic contrast media on T1 relaxation times in brain tumors.

Authors:  H J Aronen; P Niemi; K K Kwong; F S Pardo; T L Davis
Journal:  Acta Radiol       Date:  1998-09       Impact factor: 1.990

View more
  20 in total

1.  Time-resolved MR angiography of the intracranial venous system: an alternative MR venography technique.

Authors:  Hasan Yiğit; Aynur Turan; Elif Ergün; Pınar Koşar; Uğur Koşar
Journal:  Eur Radiol       Date:  2011-11-20       Impact factor: 5.315

2.  Brain Tumor-Enhancement Visualization and Morphometric Assessment: A Comparison of MPRAGE, SPACE, and VIBE MRI Techniques.

Authors:  L Danieli; G C Riccitelli; D Distefano; E Prodi; E Ventura; A Cianfoni; A Kaelin-Lang; M Reinert; E Pravatà
Journal:  AJNR Am J Neuroradiol       Date:  2019-06-20       Impact factor: 3.825

3.  Fast MR arthrography using VIBE sequences to evaluate the rotator cuff.

Authors:  Jan E Vandevenne; Filip Vanhoenacker; Jestinah M Mahachie John; Geert Gelin; Paul M Parizel
Journal:  Skeletal Radiol       Date:  2009-03-18       Impact factor: 2.199

4.  Evaluation of the pituitary gland using magnetic resonance imaging: T1-weighted vs. VIBE imaging.

Authors:  M A Davis; M Castillo
Journal:  Neuroradiol J       Date:  2013-07-16

Review 5.  State-of-the-art MRI techniques in neuroradiology: principles, pitfalls, and clinical applications.

Authors:  Magalie Viallon; Victor Cuvinciuc; Benedicte Delattre; Laura Merlini; Isabelle Barnaure-Nachbar; Seema Toso-Patel; Minerva Becker; Karl-Olof Lovblad; Sven Haller
Journal:  Neuroradiology       Date:  2015-04-10       Impact factor: 2.804

6.  Geometric distortion in magnetic resonance imaging systems assessed using an open-source plugin for scientific image analysis.

Authors:  Takahiro Aoyama; Hidetoshi Shimizu; Ikuo Shimizu; Atsushi Teramoto; Naoki Kaneda; Kazuhiko Nakamura; Masaru Nakamura; Takeshi Kodaira
Journal:  Radiol Phys Technol       Date:  2018-09-25

Review 7.  Imaging of Pediatric Stroke.

Authors:  Aashim Bhatia; Sumit Pruthi
Journal:  Indian J Pediatr       Date:  2016-02-27       Impact factor: 1.967

8.  Three-dimensional volumetric MRI with isotropic resolution: improved speed of acquisition, spatial resolution and assessment of lesion conspicuity in patients with recurrent soft tissue sarcoma.

Authors:  Shivani Ahlawat; Carol Morris; Laura M Fayad
Journal:  Skeletal Radiol       Date:  2016-02-20       Impact factor: 2.199

9.  3D fast low-angle shot (FLASH) technique for 3T contrast-enhanced brain MRI in the inpatient and emergency setting: comparison with 3D magnetization-prepared rapid gradient echo (MPRAGE) technique.

Authors:  Sohil H Patel; Prem P Batchala; Kellan Schallert; James T Patrie; Salma O Abbas; David A Ornan; Sugoto Mukherjee; Thomas Huerta; John P Mugler
Journal:  Neuroradiology       Date:  2020-10-28       Impact factor: 2.804

10.  Contrast-enhanced MR imaging of the brain using T1-weighted FLAIR with BLADE compared with a conventional spin-echo sequence.

Authors:  Shinji Naganawa; Hiroko Satake; Shingo Iwano; Hisashi Kawai; Seiji Kubota; Tomohiro Komada; Minako Kawamura; Yasuo Sakurai; Hiroshi Fukatsu
Journal:  Eur Radiol       Date:  2007-10-09       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.