Literature DB >> 8400563

Theoretical analysis of gadopentetate dimeglumine enhancement in T1-weighted imaging of the brain: comparison of two-dimensional spin-echo and three-dimensional gradient-echo sequences.

J P Mugler1, J R Brookeman.   

Abstract

By using a theoretical model, the signal difference-to-noise ratios between simulated lesions and normal white matter and gray matter were calculated as a function of lesion concentration of gadopentetate dimeglumine (GD) for two-dimensional (2D) T1-weighted spin-echo (SE), three-dimensional (3D) steady-state spoiled gradient-echo (GRE) (FLASH [fast low-angle shot]), and 3D magnetization-prepared rapid gradient echo (MP-RAGE) pulse sequences. The 3D GRE sequences provided greater contrast enhancement at relatively high [GD], and the 2D SE sequence demonstrated greater enhancement and a higher rate of enhancement at low [GD]. The results predict that at low [GD], certain lesions could probably be detected with the 2D SE sequence but possibly not with one or both of the 3D GRE sequences. At high [GD], certain lesions could probably be detected with one or both of the 3D GRE sequences but possibly not with the 2D SE sequence. This provides a potential explanation for the clinical observation that certain contrast agent-enhanced lesions appear less conspicuous on 3D GRE images than on 2D SE images and vice versa. Modified parameter values were derived for the 3D FLASH and 3D MP-RAGE sequences that are predicted to produce contrast enhancement behavior equivalent or superior to that of a conventional 2D SE sequence.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8400563     DOI: 10.1002/jmri.1880030512

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  17 in total

Review 1.  [Magnetic resonance imaging. Sequence acronyms and other abbreviations in MR imaging].

Authors:  W R Nitz
Journal:  Radiologe       Date:  2003-09       Impact factor: 0.635

2.  Three-dimensional, T1-weighted gradient-echo imaging of the brain with a volumetric interpolated examination.

Authors:  Stephan G Wetzel; Glyn Johnson; Andrew G S Tan; Soonmee Cha; Edmond A Knopp; Vivian S Lee; David Thomasson; Neil M Rofsky
Journal:  AJNR Am J Neuroradiol       Date:  2002 Jun-Jul       Impact factor: 3.825

3.  Brain Tumor-Enhancement Visualization and Morphometric Assessment: A Comparison of MPRAGE, SPACE, and VIBE MRI Techniques.

Authors:  L Danieli; G C Riccitelli; D Distefano; E Prodi; E Ventura; A Cianfoni; A Kaelin-Lang; M Reinert; E Pravatà
Journal:  AJNR Am J Neuroradiol       Date:  2019-06-20       Impact factor: 3.825

4.  MS lesions are better detected with 3D T1 gradient-echo than with 2D T1 spin-echo gadolinium-enhanced imaging at 3T.

Authors:  A Crombé; M Saranathan; A Ruet; M Durieux; E de Roquefeuil; J C Ouallet; B Brochet; V Dousset; T Tourdias
Journal:  AJNR Am J Neuroradiol       Date:  2014-11-06       Impact factor: 3.825

Review 5.  State-of-the-art MRI techniques in neuroradiology: principles, pitfalls, and clinical applications.

Authors:  Magalie Viallon; Victor Cuvinciuc; Benedicte Delattre; Laura Merlini; Isabelle Barnaure-Nachbar; Seema Toso-Patel; Minerva Becker; Karl-Olof Lovblad; Sven Haller
Journal:  Neuroradiology       Date:  2015-04-10       Impact factor: 2.804

6.  Comparison between gadolinium-enhanced 2D T1-weighted gradient-echo and spin-echo sequences in the detection of active multiple sclerosis lesions on 3.0T MRI.

Authors:  F X Aymerich; C Auger; P Alcaide-Leon; D Pareto; E Huerga; J F Corral; R Mitjana; J Sastre-Garriga; X Montalban; A Rovira
Journal:  Eur Radiol       Date:  2016-07-25       Impact factor: 5.315

Review 7.  The detectability of brain metastases using contrast-enhanced spin-echo or gradient-echo images: a systematic review and meta-analysis.

Authors:  Chong Hyun Suh; Seung Chai Jung; Kyung Won Kim; Junhee Pyo
Journal:  J Neurooncol       Date:  2016-06-20       Impact factor: 4.130

8.  Usefulness of the Delay Alternating with Nutation for Tailored Excitation Pulse with T1-Weighted Sampling Perfection with Application-Optimized Contrasts Using Different Flip Angle Evolution in the Detection of Cerebral Metastases: Comparison with MPRAGE Imaging.

Authors:  D Kim; Y J Heo; H W Jeong; J W Baek; J-Y Han; J Y Lee; S-C Jin; H J Baek
Journal:  AJNR Am J Neuroradiol       Date:  2019-08-01       Impact factor: 3.825

9.  Usefulness of contrast-enhanced T1-weighted sampling perfection with application-optimized contrasts by using different flip angle evolutions in detection of small brain metastasis at 3T MR imaging: comparison with magnetization-prepared rapid acquisition of gradient echo imaging.

Authors:  Y Kato; S Higano; H Tamura; S Mugikura; A Umetsu; T Murata; S Takahashi
Journal:  AJNR Am J Neuroradiol       Date:  2009-02-12       Impact factor: 3.825

10.  Comparison of contrast-enhanced modified T1-weighted 3D TSE black-blood and 3D MP-RAGE sequences for the detection of cerebral metastases and brain tumours.

Authors:  N N Kammer; E Coppenrath; K M Treitl; H Kooijman; O Dietrich; T Saam
Journal:  Eur Radiol       Date:  2015-09-03       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.