Literature DB >> 12002498

Hydroxyapatite coating improves fixation of pedicle screws. A clinical study.

B Sandén1, C Olerud, M Petrén-Mallmin, S Larsson.   

Abstract

We investigated the effects of hydroxyapatite (HA) coating on the purchase of pedicle screws. A total of 23 consecutive patients undergoing lumbar fusion was randomly assigned to one of three treatment groups. The first received uncoated stainless-steel screws, the second screws which were partly coated with HA, and the third screws which were fully coated. The insertion torque was recorded. After 11 to 16 months, 21 screws had been extracted. The extraction torque was recorded. Radiographs were taken to assess fusion and to detect loosening of the screws. At removal, the extraction torques exceeded the upper limit of the torque wrench (600 Ncm) for many HA-coated screws. The calculated mean extraction torque was 29 +/- 36 Ncm for the uncoated group, 447 +/- 114 Ncm for the partly-coated group and 574 +/- 52 Ncm for the fully-coated group. There were significant differences between all three groups (p < 0.001). There were more radiolucent zones surrounding the uncoated screws than the HA-coated screws (p < 0.001). HA coating of pedicle screws resulted in improved fixation with reduced risk of loosening of the screws.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12002498     DOI: 10.1302/0301-620x.84b3.12388

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  22 in total

1.  [Dynamic posterior stabilization with the cosmic system].

Authors:  Archibald von Strempel
Journal:  Oper Orthop Traumatol       Date:  2010-11       Impact factor: 1.154

2.  Insertion torque is not a good predictor of pedicle screw loosening after spinal instrumentation: a prospective study in 8 patients.

Authors:  Bengt Sandén; Claes Olerud; Sune Larsson; Yohan Robinson
Journal:  Patient Saf Surg       Date:  2010-09-03

Review 3.  Osteoporosis and the Management of Spinal Degenerative Disease (I).

Authors:  Félix Tomé-Bermejo; Angel R Piñera; Luis Alvarez-Galovich
Journal:  Arch Bone Jt Surg       Date:  2017-09

4.  Surgical treatment of osteoporotic thoraco-lumbar compressive fractures: the use of pedicle screw with augmentation PMMA.

Authors:  Massimo Girardo; P Cinnella; G Gargiulo; P Viglierchio; A Rava; S Aleotti
Journal:  Eur Spine J       Date:  2017-03-21       Impact factor: 3.134

5.  Osseodensification for enhancement of spinal surgical hardware fixation.

Authors:  Christopher D Lopez; Adham M Alifarag; Andrea Torroni; Nick Tovar; J Rodrigo Diaz-Siso; Lukasz Witek; Eduardo D Rodriguez; Paulo G Coelho
Journal:  J Mech Behav Biomed Mater       Date:  2017-01-13

Review 6.  Pedicle screw loosening: a clinically relevant complication?

Authors:  Fabio Galbusera; David Volkheimer; Sandra Reitmaier; Nikolaus Berger-Roscher; Annette Kienle; Hans-Joachim Wilke
Journal:  Eur Spine J       Date:  2015-01-24       Impact factor: 3.134

Review 7.  Surgery for degenerative lumbar spondylosis.

Authors:  J N A Gibson; G Waddell
Journal:  Cochrane Database Syst Rev       Date:  2005-10-19

8.  Inter-observer reliability of detecting Dynesys pedicle screw using plain X-rays: a study on 50 post-operative patients.

Authors:  Fras Dakhil-Jerew; H Jadeja; A Cohen; J A N Shepperd
Journal:  Eur Spine J       Date:  2009-06-16       Impact factor: 3.134

9.  Different pedicle osteosynthesis for thoracolumbar vertebral fractures in elderly patients.

Authors:  Massimo Girardo; Alessandro Rava; Federico Fusini; Giosuè Gargiulo; Angela Coniglio; Pasquale Cinnella
Journal:  Eur Spine J       Date:  2018-05-14       Impact factor: 3.134

10.  Contribution of the xenograft bone plate-screw system in lumbar transpedicular stabilization of dogs: an in-vitro study.

Authors:  Hakan Salci; Sani Sarigul; Seref Dogan; Huseyin Lekesiz; Resat Ozcan; O Sacit Gorgul; Kaya Aksoy
Journal:  J Vet Sci       Date:  2008-06       Impact factor: 1.672