Literature DB >> 11980942

Evaluation of the VITEK 2 system for identification and antimicrobial susceptibility testing of medically relevant gram-positive cocci.

Marco Ligozzi1, Cinzia Bernini, Maria Grazia Bonora, Maria De Fatima, Jessica Zuliani, Roberta Fontana.   

Abstract

A study was conducted to evaluate the new VITEK 2 system (bioMérieux) for identification and antibiotic susceptibility testing of gram-positive cocci. Clinical isolates of Staphylococcus aureus (n = 100), coagulase-negative staphylococci (CNS) (n = 100), Enterococcus spp. (n = 89), Streptococcus agalactiae (n = 29), and Streptococcus pneumoniae (n = 66) were examined with the ID-GPC identification card and with the AST-P515 (for staphylococci), AST-P516 (for enterococci and S. agalactiae) and AST-P506 (for pneumococci) susceptibility cards. The identification comparison methods were the API Staph for staphylococci and the API 20 Strep for streptococci and enterococci; for antimicrobial susceptibility testing, the agar dilution method according to the procedure of the National Committee for Clinical Laboratory Standards (NCCLS) was used. The VITEK 2 system correctly identified to the species level (only one choice or after simple supplementary tests) 99% of S. aureus, 96.5% of S. agalactiae, 96.9% of S. pneumoniae, 92.7% of Enterococcus faecalis, 91.3% of Staphylococcus haemolyticus, and 88% of Staphylococcus epidermidis but was least able to identify Enterococcus faecium (71.4% correct). More than 90% of gram-positive cocci were identified within 3 h. According to the NCCLS breakpoints, antimicrobial susceptibility testing with the VITEK 2 system gave 96% correct category agreement, 0.82% very major errors, 0.17% major errors, and 2.7% minor errors. Antimicrobial susceptibility testing showed category agreement from 94 to 100% for S. aureus, from 90 to 100% for CNS, from 91 to 100% for enterococci, from 96 to 100% for S. agalactiae, and from 91 to 100% for S. pneumoniae. Microorganism-antibiotic combinations that gave very major errors were CNS-erythromycin, CNS-oxacillin, enterococci-teicoplanin, and enterococci-high-concentration gentamicin. Major errors were observed for CNS-oxacillin and S. agalactiae-tetracycline combinations. In conclusion the results of this study indicate that the VITEK 2 system represents an accurate and acceptable means for performing identification and antibiotic susceptibility tests with medically relevant gram-positive cocci.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11980942      PMCID: PMC130656          DOI: 10.1128/JCM.40.5.1681-1686.2002

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  13 in total

1.  Evaluation of a new system, VITEK 2, for identification and antimicrobial susceptibility testing of enterococci.

Authors:  F Garcia-Garrote; E Cercenado; E Bouza
Journal:  J Clin Microbiol       Date:  2000-06       Impact factor: 5.948

Review 2.  Automated systems for identification of microorganisms.

Authors:  C E Stager; J R Davis
Journal:  Clin Microbiol Rev       Date:  1992-07       Impact factor: 26.132

3.  Evaluation of the VITEK 2 system for rapid identification of medically relevant gram-negative rods.

Authors:  G Funke; D Monnet; C deBernardis; A von Graevenitz; J Freney
Journal:  J Clin Microbiol       Date:  1998-07       Impact factor: 5.948

4.  Penicillin-binding proteins and the intrinsic resistance to beta-lactams in gram-positive cocci.

Authors:  R Fontana
Journal:  J Antimicrob Chemother       Date:  1985-10       Impact factor: 5.790

5.  Clinical and financial benefits of rapid bacterial identification and antimicrobial susceptibility testing.

Authors:  J Barenfanger; C Drake; G Kacich
Journal:  J Clin Microbiol       Date:  1999-05       Impact factor: 5.948

Review 6.  The life and times of the Enterococcus.

Authors:  B E Murray
Journal:  Clin Microbiol Rev       Date:  1990-01       Impact factor: 26.132

Review 7.  Laboratory, clinical, and epidemiological aspects of coagulase-negative staphylococci.

Authors:  M A Pfaller; L A Herwaldt
Journal:  Clin Microbiol Rev       Date:  1988-07       Impact factor: 26.132

8.  Resistance of enterococci to ampicillin and glycopeptide antibiotics in Italy. The Italian Surveillance Group for Antimicrobial Resistance.

Authors:  R Fontana; M Ligozzi; A Mazzariol; G Veneri; G Cornaglia
Journal:  Clin Infect Dis       Date:  1998-08       Impact factor: 9.079

9.  Ability of clinical laboratories to detect antimicrobial agent-resistant enterococci.

Authors:  F C Tenover; J Tokars; J Swenson; S Paul; K Spitalny; W Jarvis
Journal:  J Clin Microbiol       Date:  1993-07       Impact factor: 5.948

10.  Characterization of Tn1546, a Tn3-related transposon conferring glycopeptide resistance by synthesis of depsipeptide peptidoglycan precursors in Enterococcus faecium BM4147.

Authors:  M Arthur; C Molinas; F Depardieu; P Courvalin
Journal:  J Bacteriol       Date:  1993-01       Impact factor: 3.490

View more
  55 in total

1.  Evaluation of the automated phoenix system for potential routine use in the clinical microbiology laboratory.

Authors:  J-L Donay; D Mathieu; P Fernandes; C Prégermain; P Bruel; A Wargnier; I Casin; F X Weill; P H Lagrange; J L Herrmann
Journal:  J Clin Microbiol       Date:  2004-04       Impact factor: 5.948

2.  Evaluation of the Essen Rotary as a new technique for bacterial swabs: results of a prospective controlled clinical investigation in 50 patients with chronic leg ulcers.

Authors:  Philipp Al Ghazal; Andreas Körber; Joachim Klode; Ernst N Schmid; Jan Buer; Joachim Dissemond
Journal:  Int Wound J       Date:  2012-07-09       Impact factor: 3.315

3.  Identification of clinically relevant viridans group streptococci by phenotypic and genotypic analysis.

Authors:  C Teles; A Smith; G Ramage; S Lang
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2010-10-28       Impact factor: 3.267

4.  Validation of VITEK 2 version 4.01 software for detection, identification, and classification of glycopeptide-resistant enterococci.

Authors:  Marianne Abele-Horn; Leif Hommers; René Trabold; Matthias Frosch
Journal:  J Clin Microbiol       Date:  2006-01       Impact factor: 5.948

5.  Evaluation of the BD PHOENIX automated microbiology system for detection of methicillin resistance in coagulase-negative staphylococci.

Authors:  Matthias A Horstkotte; Johannes K-M Knobloch; Holger Rohde; Sabine Dobinsky; Dietrich Mack
Journal:  J Clin Microbiol       Date:  2004-11       Impact factor: 5.948

6.  Performance of the new VITEK 2 GP card for identification of medically relevant gram-positive cocci in a routine clinical laboratory.

Authors:  Guido Funke; Pascale Funke-Kissling
Journal:  J Clin Microbiol       Date:  2005-01       Impact factor: 5.948

7.  Erroneous reporting of coagulase-negative Staphylococci as Kocuria spp. by the Vitek 2 system.

Authors:  R Ben-Ami; S Navon-Venezia; D Schwartz; Y Schlezinger; Y Mekuzas; Y Carmeli
Journal:  J Clin Microbiol       Date:  2005-03       Impact factor: 5.948

8.  Use of the MicroSeq 500 16S rRNA gene-based sequencing for identification of bacterial isolates that commercial automated systems failed to identify correctly.

Authors:  Carla Fontana; Marco Favaro; Marco Pelliccioni; Enrico Salvatore Pistoia; Cartesio Favalli
Journal:  J Clin Microbiol       Date:  2005-02       Impact factor: 5.948

9.  Accuracy of identification and susceptibility results by direct inoculation of Vitek 2 cards from positive BACTEC cultures.

Authors:  J J Kerremans; W H F Goessens; H A Verbrugh; M C Vos
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2004-12       Impact factor: 3.267

10.  Development of a new oligonucleotide array to identify staphylococcal strains at species level.

Authors:  Philippe Giammarinaro; Sabine Leroy; Jean-Paul Chacornac; Julien Delmas; Regine Talon
Journal:  J Clin Microbiol       Date:  2005-08       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.