Film dosimetry for intensity modulated radiation therapy: dosimetric evaluation.

Sang Gyu Ju1, Yong Chan Ahn, Seung Jae Huh, Inhwan Jason Yeo.   

Abstract

X-ray film has been used for the dosimetry of intensity modulated radiation therapy (IMRT). However, the over-response of the film to low-energy photons is a significant problem in photon beam dosimetry, especially in regions outside penumbra. In IMRT, the radiation field consists of multiple small fields and their outside-penumbra regions; thus, the film dosimetry, for it involves the source of over-response in its radiation field. In this study we aim to verify and possibly improve film dosimetry for IMRT. Two types of modulated beams were constructed by combining five to seven different static radiation fields using 6 MV x rays. For verifying film dosimetry, x-ray films and an ion chamber were used to measure dose profiles at various depths in a phantom. The film setups include both parallel and perpendicular arrangements against the beam incident direction. In addition, to reduce an over-response, we placed 0.01 in. (0.25 mm) thick lead filters on both sides of the film. Compared with ion-chamber measurement, measured dose profiles showed the film over-response at outside-penumbra and low-dose regions. The error increased with depths and approached 15% as a maximum for the field size of 15 cm x 15 cm at 10 cm depth. The use of filters reduced the error down to 3%. In this study we demonstrated that film dosimetry for IMRT involves sources of error due to its over-response to low-energy photons, with the error most transparent in the low-dose region. The use of filters could enhance the accuracy in film dosimetry for IMRT. In this regard, the use of an optimal filter condition is recommended.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11929018     DOI: 10.1118/1.1449493

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  19 in total

1.  A calibration method for patient specific IMRT QA using a single therapy verification film.

Authors:  Arvind Kumar Shukla; Arun S Oinam; Sanjeev Kumar; I S Sandhu; S C Sharma
Journal:  Rep Pract Oncol Radiother       Date:  2013-05-24

2.  Optical imaging provides rapid verification of static small beams, radiosurgery, and VMAT plans with millimeter resolution.

Authors:  Muhammad Ramish Ashraf; Petr Bruza; Brian W Pogue; Nathan Nelson; Benjamin B Williams; Lesley A Jarvis; David J Gladstone
Journal:  Med Phys       Date:  2019-10-04       Impact factor: 4.071

3.  Dosimetric properties and clinical application of an a-Si EPID for dynamic IMRT quality assurance.

Authors:  Kenji Matsumoto; Masahiko Okumura; Yoshiyuki Asai; Kouhei Shimomura; Masaya Tamura; Yasumasa Nishimura
Journal:  Radiol Phys Technol       Date:  2012-12-04

4.  Dose distribution verifications of IMRT for NPC.

Authors:  Qin Li; Liang Li; Jun Han; Zhiwen Liang
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2009-10-11

5.  Dosimetric verification of compensated beams using radiographic film.

Authors:  Slaven Jurkovic; Gordana Zauhar; Dario Faj; Deni Smilovic Radojcic; Manda Svabic; Mladen Kasabasic; Ana Diklic
Journal:  Radiol Oncol       Date:  2011-07-20       Impact factor: 2.991

6.  Evaluation of PTW Seven29 for tomotherapy patient-specific quality assurance and comparison with ScandiDos Delta(4).

Authors:  Pamela Myers; Sotirios Stathakis; Alonso N Gutiérrez; Carlos Esquivel; Panayiotis Mavroidis; Niko Papanikolaou
Journal:  J Med Phys       Date:  2012-04

7.  Comparison of four commercial devices for RapidArc and sliding window IMRT QA.

Authors:  Varatharaj Chandraraj; Sotirios Stathakis; Ravikumar Manickam; Carlos Esquivel; Sanjay S Supe; Nikos Papanikolaou
Journal:  J Appl Clin Med Phys       Date:  2011-04-04       Impact factor: 2.102

8.  Evaluation of a software system for estimating planned dose error in patients, based on planar IMRT QA measurements.

Authors:  Mohammad Bakhtiari; Ashkan Parniani; Fritz Lerma; Shannon Reynolds; James Jordan; Alireza Sedaghat; Mehrdad Sarfaraz; James Rodgers
Journal:  Radiol Oncol       Date:  2014-01-22       Impact factor: 2.991

9.  A light-field-based method to adjust on-axis rounded leaf end MLC position to predict off-axis MLC penumbra region dosimetric performance in a radiation therapy planning system.

Authors:  Jia-Ming Wu; Tsair-Fwu Lee; Shyh-An Yeh; Kuan-Yin Hsiao; Hsin-Hsiung Chen; Pei-Ju Chao; Yi-Ting Chen
Journal:  Biomed Res Int       Date:  2013-10-24       Impact factor: 3.411

10.  Accuracy of rapid radiographic film calibration for intensity-modulated radiation therapy verification.

Authors:  Ravi Kulasekere; Jean M Moran; Benedick A Fraass; Peter L Roberson
Journal:  J Appl Clin Med Phys       Date:  2006-05-25       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.