Literature DB >> 11786053

Quantitative performance of bifocal and multifocal intraocular lenses in a model eye: point spread function in multifocal intraocular lenses.

Stefan Pieh1, Patrick Marvan, Birgit Lackner, Georg Hanselmayer, Gerald Schmidinger, Rainer Leitgeb, Markus Sticker, Christoph K Hitzenberger, Adolf F Fercher, Christian Skorpik.   

Abstract

OBJECTIVE: To compare the optical properties of bifocal diffractive and multifocal refractive intraocular lenses.
METHODS: A model eye with a pupil 4.5 mm in diameter was used to determine the point spread function (PSF) of the distance focus and near focus of a diffractive bifocal intraocular lens (IOL) (model 811E; Pharmacia Inc, Columbus, Ohio) and of a refractive multifocal IOL (model SA40N; Allergan Optical Inc, Irvine, Calif) to compare them with PSFs of foci of corresponding monofocal lenses. For interpreting the PSFs the through focus response, the modulation transfer function, and the Strehl ratio were evaluated.
RESULTS: The intensity of the distance focus of the bifocal diffractive lens reached 58.5% and the near focus attained 42.7% of the intensity of a corresponding monofocal lens. The maximal halo intensity surrounding both foci was approximately 4.5%. The distance peak of the refractive multifocal IOL was 73.4% and the near peak 25.1% of a corresponding monofocal lens. The out-of-focus image overlaying the distance focus of the refractive multifocal IOL was approximately 3% of the light intensity of the distance focus, whereas the PSF of the near focus of the multifocal IOL is substantially affected by out-of-focus images. The computed modulation transfer functions show better results for the monofocal lenses, similar results for the tested distance foci, and clear advantages for the bifocal diffractive near focus.
CONCLUSIONS: Modulation transfer functions reveal comparable properties for distance vision and a superiority of the bifocal diffractive lens over the refractive multifocal lens for near vision.

Entities:  

Mesh:

Year:  2002        PMID: 11786053     DOI: 10.1001/archopht.120.1.23

Source DB:  PubMed          Journal:  Arch Ophthalmol        ISSN: 0003-9950


  14 in total

1.  A dual optic accommodating foldable intraocular lens.

Authors:  S D McLeod; V Portney; A Ting
Journal:  Br J Ophthalmol       Date:  2003-09       Impact factor: 4.638

Review 2.  [Vision with bifocal and multifocal intraocular lenses].

Authors:  K Kirschfeld; M F Land
Journal:  Ophthalmologe       Date:  2011-12       Impact factor: 1.059

3.  Visual simulation of retinal images through a decentered monofocal and a refractive multifocal intraocular lens.

Authors:  Kazuno Negishi; Kazuhiko Ohnuma; Takashi Ikeda; Toru Noda
Journal:  Jpn J Ophthalmol       Date:  2005 Jul-Aug       Impact factor: 2.447

4.  Star testing: a novel evaluation of intraocular lens optical quality.

Authors:  L Mitchell; A C B Molteno; T H Bevin; G Sanderson
Journal:  Br J Ophthalmol       Date:  2006-05       Impact factor: 4.638

5.  Evaluation of refractive correction for standard automated perimetry in eyes wearing multifocal contact lenses.

Authors:  Kazunori Hirasawa; Hikaru Ito; Yukari Ohori; Yui Takano; Nobuyuki Shoji
Journal:  Int J Ophthalmol       Date:  2017-10-18       Impact factor: 1.779

6.  [Functional results with two multifocal intraocular lenses (MIOL). Array SA40 versus Acri.Twin].

Authors:  U Mester; P Dillinger; N Anterist; H Kaymak
Journal:  Ophthalmologe       Date:  2005-11       Impact factor: 1.059

Review 7.  Opto-Mechanical Eye Models, a Review on Human Vision Applications and Perspectives for Use in Industry.

Authors:  André Rino Amorim; Boris Bret; José M González-Méijome
Journal:  Sensors (Basel)       Date:  2022-10-10       Impact factor: 3.847

8.  Wavefront analysis and modulation transfer function of three multifocal intraocular lenses.

Authors:  Marcony R Santhiago; Marcelo V Netto; Jackson Barreto; Beatriz A F Gomes; Arthur Schaefer; Newton Kara-Junior
Journal:  Indian J Ophthalmol       Date:  2010 Mar-Apr       Impact factor: 1.848

9.  Visual Performance of Tecnis ZM900 Diffractive Multifocal IOL after 2500 Implants: A 3-Year Followup.

Authors:  Leonardo Akaishi; Rodrigo Vaz; Graziela Vilella; Rodrigo C Garcez; Patrick F Tzelikis
Journal:  J Ophthalmol       Date:  2010-10-05       Impact factor: 1.909

10.  A contralateral eye study comparing apodized diffractive and full diffractive lenses: wavefront analysis and distance and near uncorrected visual acuity.

Authors:  Marcony Rodrigues de Santhiago; Marcelo Vieira Netto; Jackson Barreto; Beatriz de Abreu Fiuza Gomes; Arthur Schaefer; Newton Kara-Junior
Journal:  Clinics (Sao Paulo)       Date:  2009       Impact factor: 2.365

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.