Literature DB >> 23900921

Device localization and dynamic scan plane selection using a wireless magnetic resonance imaging detector array.

Matthew J Riffe1, Stephen R Yutzy, Yun Jiang, Michael D Twieg, Colin J Blumenthal, Daniel P Hsu, Li Pan, Wesley D Gilson, Jeffrey L Sunshine, Christopher A Flask, Jeffrey L Duerk, Dean Nakamoto, Vikas Gulani, Mark A Griswold.   

Abstract

PURPOSE: A prototype wireless guidance device using single sideband amplitude modulation (SSB) is presented for a 1.5T magnetic resonance imaging system.
METHODS: The device contained three fiducial markers each mounted to an independent receiver coil equipped with wireless SSB technology. Acquiring orthogonal projections of these markers determined the position and orientation of the device, which was used to define the scan plane for a subsequent image acquisition. Device localization and scan plane update required approximately 30 ms, so it could be interleaved with high temporal resolution imaging. Since the wireless device is used for localization and does not require full imaging capability, the design of the SSB wireless system was simplified by allowing an asynchronous clock between the transmitter and receiver.
RESULTS: When coupled to a high readout bandwidth, the error caused by the lack of a shared frequency reference was quantified to be less than one pixel (0.78 mm) in the projection acquisitions. Image guidance with the prototype was demonstrated with a phantom where a needle was successfully guided to a target and contrast was delivered.
CONCLUSION: The feasibility of active tracking with a wireless detector array is demonstrated. Wireless arrays could be incorporated into devices to assist in image-guided procedures.
Copyright © 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  magnetic resonance imaging; microcoil tracking; single sideband amplitude modulation; wireless link

Mesh:

Year:  2013        PMID: 23900921      PMCID: PMC3907494          DOI: 10.1002/mrm.24853

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  21 in total

1.  Active biplanar MR tracking for biopsies in humans.

Authors:  P Steiner; P Erhart; N Heske; C L Dumoulin; G K von Schulthess; J F Debatin
Journal:  AJR Am J Roentgenol       Date:  1997-09       Impact factor: 3.959

2.  MR-guided breast biopsy using an active marker: a phantom study.

Authors:  Richard Werner; Sascha Krueger; Axel Winkel; Christoph Albrecht; Tobias Schaeffter; Martin Heller; Christian Frahm
Journal:  J Magn Reson Imaging       Date:  2006-07       Impact factor: 4.813

3.  A realization of digital wireless transmission for MRI signals based on 802.11b.

Authors:  Juan Wei; Zhengguang Liu; Zhi Chai; Jing Yuan; Jianyu Lian; Gary X Shen
Journal:  J Magn Reson       Date:  2007-03-12       Impact factor: 2.229

4.  Targeted-HASTE imaging with automated device tracking for MR-guided needle interventions in closed-bore MR systems.

Authors:  H Zimmermann; S Müller; B Gutmann; H Bardenheuer; A Melzer; R Umathum; W Nitz; W Semmler; M Bock
Journal:  Magn Reson Med       Date:  2006-09       Impact factor: 4.668

5.  ACR guidance document for safe MR practices: 2007.

Authors:  Emanuel Kanal; A James Barkovich; Charlotte Bell; James P Borgstede; William G Bradley; Jerry W Froelich; Tobias Gilk; J Rod Gimbel; John Gosbee; Ellisa Kuhni-Kaminski; James W Lester; John Nyenhuis; Yoav Parag; Daniel J Schaefer; Elizabeth A Sebek-Scoumis; Jeffrey Weinreb; Loren A Zaremba; Pamela Wilcox; Leonard Lucey; Nancy Sass
Journal:  AJR Am J Roentgenol       Date:  2007-06       Impact factor: 3.959

6.  A direct modulated optical link for MRI RF receive coil interconnection.

Authors:  Jing Yuan; Juan Wei; G X Shen
Journal:  J Magn Reson       Date:  2007-08-29       Impact factor: 2.229

Review 7.  MR-guided biopsy: a review of current techniques and applications.

Authors:  Clifford R Weiss; Sherif Gamal Nour; Jonathan S Lewin
Journal:  J Magn Reson Imaging       Date:  2008-02       Impact factor: 4.813

8.  Dynamic scan-plane tracking using MR position monitoring.

Authors:  J A Derbyshire; G A Wright; R M Henkelman; R S Hinks
Journal:  J Magn Reson Imaging       Date:  1998 Jul-Aug       Impact factor: 4.813

9.  Identification and mitigation of interference sources present in SSB-based wireless MRI receiver arrays.

Authors:  Matthew J Riffe; Michael D Twieg; Natalia Gudino; Colin J Blumenthal; Jeremiah A Heilman; Mark A Griswold
Journal:  Magn Reson Med       Date:  2013-02-14       Impact factor: 4.668

10.  Flexible add-on solution for MR image-guided interventions in a closed-bore scanner environment.

Authors:  Harald Busse; Nikita Garnov; Gregor Thörmer; Dirk Zajonz; Wilfried Gründer; Thomas Kahn; Michael Moche
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

View more
  3 in total

Review 1.  Enabling Technology for MRI-Guided Intervention.

Authors:  Farzad Sedaghat; Kemal Tuncali
Journal:  Top Magn Reson Imaging       Date:  2018-02

2.  Wireless Reconfigurable RF Detector Array for Focal and Multiregional Signal Enhancement.

Authors:  Wei Qian; Xin Yu; Chunqi Qian
Journal:  IEEE Access       Date:  2020-07-24       Impact factor: 3.367

3.  Wireless Powered Encoding and Broadcasting of Frequency Modulated Detection Signals.

Authors:  Wei Qian; Xin Yu; Chunqi Qian
Journal:  IEEE Access       Date:  2020-11-04       Impact factor: 3.367

  3 in total