Literature DB >> 2015136

Systemic effects of implanted prostheses made of cobalt-chromium alloys.

R Michel1, M Nolte, M Reich, F Löer.   

Abstract

Systemic effects of Co-Cr alloy/polyethylene hip joint prostheses were investigated using instrumental neutron activation to determine the concentrations of up to 16 elements. First, in a prospective study whole blood and serum taken from 10 patients from 1 day before to 90 days after implantation were analyzed. Secondly, in a retrospective study whole blood and serum from 23 patients who had had prostheses in place for up to 18 years were analyzed. For comparison, normal trace element levels in humans were determined by analyzing whole blood and serum from 21 patients. Finally, various tissues and organs from two decreased implant patients were analyzed and compared with normal concentrations obtained from the analysis of five "normal" patients without implants. In agreement with other recent investigations, our analyses of normal serum, whole blood, tissues, and organs show that most previously defined "normal" trace element concentrations were too high, chiefly owing to contamination and insufficient blanks. A detailed discussion shows that for many elements the ranges of normal concentrations have to be revised. This conclusion is of particular importance with respect to the sometimes conflicting earlier reports of systemic effects of metal prostheses. In the work reported here, both the prospective and the retrospective investigations of serum and whole blood showed massive Co enrichments as a consequence of implant corrosion. The data show a wide range of individual burdening, ranging from practically no effect to the most extreme values. The analyses of tissues from the vicinity of the implants in the two deceased implant patients showed strong local effects of Co, Cr, Zr, and Hf, the latter two elements originating from the X-ray contrast media in the bone cement. The analyses of organs revealed significant Co and Cr enrichment in several tissues and organs. Consequently, it can be seen that implant corrosion is not an occurrence of merely local significance, but one that affects the trace element status of the entire organism.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 2015136     DOI: 10.1007/bf00393876

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  14 in total

1.  Trace elements in human livers using quality control in the complete analytical process.

Authors:  R Zeisler; S H Harrison; S A Wise
Journal:  Biol Trace Elem Res       Date:  1984-02       Impact factor: 3.738

2.  Reference values for the concentrations of As, Cd, Co, Cr, Cu, Fe, I, Hg, Mn, Mo, Ni, Pb, Se, and Zn in selected human tissues and body fluids.

Authors:  G V Iyengar
Journal:  Biol Trace Elem Res       Date:  1987-04       Impact factor: 3.738

3.  Does corrosion matter?

Authors:  J Black
Journal:  J Bone Joint Surg Br       Date:  1988-08

4.  [Normal values of trace elements in human serum and their correlation with age and serum protein concentration].

Authors:  K Kasperek; H Schicha; V Siller; L E Feinendegen
Journal:  Strahlentherapie       Date:  1972-04

Review 5.  Trace elements in human body fluids and tissues.

Authors:  J Versieck
Journal:  Crit Rev Clin Lab Sci       Date:  1985       Impact factor: 6.250

6.  [Tissue burden with exogenous trace elements caused by roentgen contrast media in bone cements].

Authors:  F Löer; J Zilkens; R Michel; G Freisem-Broda; K H Bigalke
Journal:  Z Orthop Ihre Grenzgeb       Date:  1983 May-Jun

Review 7.  The essential trace elements.

Authors:  W Mertz
Journal:  Science       Date:  1981-09-18       Impact factor: 47.728

8.  Cobalt toxicity after McKee hip arthroplasty.

Authors:  D A Jones; H K Lucas; M O'Driscoll; C H Price; B Wibberley
Journal:  J Bone Joint Surg Br       Date:  1975-08

9.  Metal ion release after total hip replacement.

Authors:  H S Dobbs; M J Minski
Journal:  Biomaterials       Date:  1980-10       Impact factor: 12.479

10.  The incidence of cancer following total hip replacement.

Authors:  W J Gillespie; C M Frampton; R J Henderson; P M Ryan
Journal:  J Bone Joint Surg Br       Date:  1988-08
View more
  10 in total

1.  Metallosis following a dual coat porous hydroxyapatite shoulder hemiarthroplasty.

Authors:  Humza Khan; Mark Hurworth; Alan Kop
Journal:  J Orthop       Date:  2015-03-12

2.  Geltape method for measurement of work related surface contamination with cobalt containing dust: correlation between surface contamination and airborne exposure.

Authors:  O M Poulsen; E Olsen; J M Christensen; P Vinzent; O H Petersen
Journal:  Occup Environ Med       Date:  1995-12       Impact factor: 4.402

3.  A short-term cross-over study on oral administration of soluble and insoluble cobalt compounds: sex differences in biological levels.

Authors:  J M Christensen; O M Poulsen; M Thomsen
Journal:  Int Arch Occup Environ Health       Date:  1993       Impact factor: 3.015

4.  Orthopaedic implant related metal toxicity in terms of human lymphocyte reactivity to metal-protein complexes produced from cobalt-base and titanium-base implant alloy degradation.

Authors:  N J Hallab; K Mikecz; C Vermes; A Skipor; J J Jacobs
Journal:  Mol Cell Biochem       Date:  2001-06       Impact factor: 3.396

5.  Changes of concentrations of the elements Co, Cr, Sb, and Sc in tissues of persons with joint implants.

Authors:  C Schnabel; U Herpers; R Michel; F Löer; G Buchhorn; H G Willert
Journal:  Biol Trace Elem Res       Date:  1994       Impact factor: 3.738

6.  Ten-year outcome of serum metal ion levels after primary total hip arthroplasty: a concise follow-up of a previous report*.

Authors:  Brett R Levine; Andrew R Hsu; Anastasia K Skipor; Nadim J Hallab; Wayne G Paprosky; Jorge O Galante; Joshua J Jacobs
Journal:  J Bone Joint Surg Am       Date:  2013-03-20       Impact factor: 5.284

7.  Spectrophotometric Determination of Iron(II) and Cobalt(II) by Direct, Derivative, and Simultaneous Methods Using 2-Hydroxy-1-Naphthaldehyde-p-Hydroxybenzoichydrazone.

Authors:  V S Anusuya Devi; V Krishna Reddy
Journal:  Int J Anal Chem       Date:  2012-02-27       Impact factor: 1.885

8.  A review of the biologic effects of spine implant debris: Fact from fiction.

Authors:  Nadim James Hallab
Journal:  SAS J       Date:  2009-12-01

9.  Hypersensitivity reactions to metal implants: laboratory options.

Authors:  Anna Maria Carossino; Christian Carulli; Simone Ciuffi; Roberto Carossino; Giorgia Donata Zappoli Thyrion; Roberto Zonefrati; Massimo Innocenti; Maria Luisa Brandi
Journal:  BMC Musculoskelet Disord       Date:  2016-11-23       Impact factor: 2.362

10.  Cytotoxic effects of cobalt and nickel ions on osteocytes in vitro.

Authors:  Arihiko Kanaji; Vbenosawemwinghaye Orhue; Marco S Caicedo; Amarjit S Virdi; Dale R Sumner; Nadim J Hallab; Toyama Yoshiaki; Kotaro Sena
Journal:  J Orthop Surg Res       Date:  2014-10-08       Impact factor: 2.359

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.