Evaluation of the VITEK 2 system for the identification and susceptibility testing of three species of nonfermenting gram-negative rods frequently isolated from clinical samples.

P Joyanes1, M del Carmen Conejo, L Martínez-Martínez, E J Perea.   

Abstract

VITEK 2 is a new automatic system for the identification and susceptibility testing of the most clinically important bacteria. In the present study 198 clinical isolates, including Pseudomonas aeruginosa (n = 146), Acinetobacter baumannii (n = 25), and Stenotrophomonas maltophilia (n = 27) were evaluated. Reference susceptibility testing of cefepime, cefotaxime, ceftazidime, ciprofloxacin, gentamicin, imipenem, meropenem, piperacillin, tobramycin, levofloxacin (only for P. aeruginosa), co-trimoxazole (only for S. maltophilia), and ampicillin-sulbactam and tetracycline (only for A. baumannii) was performed by microdilution (NCCLS guidelines). The VITEK 2 system correctly identified 91.6, 100, and 76% of P. aeruginosa, S. maltophilia, and A. baumannii isolates, respectively, within 3 h. The respective percentages of essential agreement (to within 1 twofold dilution) for P. aeruginosa and A. baumannii were 89.0 and 88.0% (cefepime), 91.1 and 100% (cefotaxime), 95.2 and 96.0% (ceftazidime), 98.6 and 100% (ciprofloxacin), 88.4 and 100% (gentamicin), 87.0 and 92.0% (imipenem), 85.0 and 88.0% (meropenem), 84.2 and 96.0% (piperacillin), and 97.3 and 80% (tobramycin). The essential agreement for levofloxacin against P. aeruginosa was 86.3%. The percentages of essential agreement for ampicillin-sulbactam and tetracycline against A. baumannii were 88.0 and 100%, respectively. Very major errors for P. aeruginosa (resistant by the reference method, susceptible with the VITEK 2 system [resistant to susceptible]) were noted for cefepime (0.7%), cefotaxime (0.7%), gentamicin (0.7%), imipenem (1.4%), levofloxacin (2.7%), and piperacillin (2.7%) and, for one strain of A. baumannii, for imipenem. Major errors (susceptible to resistant) were noted only for P. aeruginosa and cefepime (2.0%), ceftazidime (0.7%), and piperacillin (3.4%). Minor errors ranged from 0.0% for piperacillin to 22.6% for cefotaxime against P. aeruginosa and from 0.0% for piperacillin and ciprofloxacin to 20.0% for cefepime against A. baumannii. The VITEK 2 system provided co-trimoxazole MICs only for S. maltophilia; no very major or major errors were obtained for co-trimoxazole against this species. It is concluded that the VITEK 2 system allows the rapid identification of S. maltophilia and most P. aeruginosa and A. baumannii isolates. The VITEK 2 system can perform reliable susceptibility testing of many of the antimicrobial agents used against P. aeruginosa and A. baumannii. It would be desirable if new versions of the VITEK 2 software were able to determine MICs and the corresponding clinical categories of agents active against S. maltophilia.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11526158      PMCID: PMC88326          DOI: 10.1128/JCM.39.9.3247-3253.2001

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  19 in total

1.  Ability of the VITEK 2 advanced expert system To identify beta-lactam phenotypes in isolates of Enterobacteriaceae and Pseudomonas aeruginosa.

Authors:  C C Sanders; M Peyret; E S Moland; C Shubert; K S Thomson; J M Boeufgras; W E Sanders
Journal:  J Clin Microbiol       Date:  2000-02       Impact factor: 5.948

2.  Interplay of impermeability and chromosomal beta-lactamase activity in imipenem-resistant Pseudomonas aeruginosa.

Authors:  D M Livermore
Journal:  Antimicrob Agents Chemother       Date:  1992-09       Impact factor: 5.191

Review 3.  Automated systems for identification of microorganisms.

Authors:  C E Stager; J R Davis
Journal:  Clin Microbiol Rev       Date:  1992-07       Impact factor: 26.132

4.  Evaluation of the Autoscan Walkaway system for rapid identification and susceptibility testing of gram-negative bacilli.

Authors:  M T Kelly; C Leicester
Journal:  J Clin Microbiol       Date:  1992-06       Impact factor: 5.948

5.  False resistance to imipenem with a microdilution susceptibility testing system.

Authors:  E J O'Rourke; K G Lambert; K C Parsonnet; A B Macone; D A Goldmann
Journal:  J Clin Microbiol       Date:  1991-04       Impact factor: 5.948

6.  Comparison of the autoSCAN-W/A and Vitek Automicrobic systems for identification and susceptibility testing of bacteria.

Authors:  M R Visser; L Bogaards; M Rozenberg-Arska; J Verhoef
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1992-11       Impact factor: 3.267

7.  Evaluation of autoSCAN-W/A automated microbiology system for the identification of non-glucose-fermenting gram-negative bacilli.

Authors:  F C Tenover; T S Mizuki; L G Carlson
Journal:  J Clin Microbiol       Date:  1990-07       Impact factor: 5.948

8.  Delineation of new proteolytic genomic species in the genus Acinetobacter.

Authors:  P J Bouvet; S Jeanjean
Journal:  Res Microbiol       Date:  1989 May-Jun       Impact factor: 3.992

9.  Clinical and financial benefits of rapid bacterial identification and antimicrobial susceptibility testing.

Authors:  J Barenfanger; C Drake; G Kacich
Journal:  J Clin Microbiol       Date:  1999-05       Impact factor: 5.948

10.  Pseudoresistance of Pseudomonas aeruginosa resulting from degradation of imipenem in an automated susceptibility testing system with predried panels.

Authors:  R L White; M B Kays; L V Friedrich; E W Brown; J R Koonce
Journal:  J Clin Microbiol       Date:  1991-02       Impact factor: 5.948

View more
  35 in total

1.  In vivo selection of a missense mutation in adeR and conversion of the novel blaOXA-164 gene into blaOXA-58 in carbapenem-resistant Acinetobacter baumannii isolates from a hospitalized patient.

Authors:  Paul G Higgins; Thamarai Schneiders; Axel Hamprecht; Harald Seifert
Journal:  Antimicrob Agents Chemother       Date:  2010-10-04       Impact factor: 5.191

2.  Evaluation of the Vitek 2 system for rapid identification of clinical isolates of gram-negative bacilli and members of the family Streptococcaceae.

Authors:  P J Gavin; J R Warren; A A Obias; S M Collins; L R Peterson
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2002-12-10       Impact factor: 3.267

3.  Use of positive blood cultures for direct identification and susceptibility testing with the vitek 2 system.

Authors:  Marina de Cueto; Esther Ceballos; Luis Martinez-Martinez; Evelio J Perea; Alvaro Pascual
Journal:  J Clin Microbiol       Date:  2004-08       Impact factor: 5.948

4.  Evaluation of the new VITEK 2 card for identification of clinically relevant gram-negative rods.

Authors:  Guido Funke; Pascale Funke-Kissling
Journal:  J Clin Microbiol       Date:  2004-09       Impact factor: 5.948

5.  Evaluation of the automated phoenix system for potential routine use in the clinical microbiology laboratory.

Authors:  J-L Donay; D Mathieu; P Fernandes; C Prégermain; P Bruel; A Wargnier; I Casin; F X Weill; P H Lagrange; J L Herrmann
Journal:  J Clin Microbiol       Date:  2004-04       Impact factor: 5.948

Review 6.  Manual and automated instrumentation for identification of Enterobacteriaceae and other aerobic gram-negative bacilli.

Authors:  Caroline M O'hara
Journal:  Clin Microbiol Rev       Date:  2005-01       Impact factor: 26.132

7.  Evaluation of the new Vitek 2 GN card for the identification of gram-negative bacilli frequently encountered in clinical laboratories.

Authors:  F N R Renaud; E Bergeron; S Tigaud; C Fuhrmann; B Gravagna; J Freney
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2005-10       Impact factor: 3.267

8.  Accuracy of identification and susceptibility results by direct inoculation of Vitek 2 cards from positive BACTEC cultures.

Authors:  J J Kerremans; W H F Goessens; H A Verbrugh; M C Vos
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2004-12       Impact factor: 3.267

9.  Quality control for beta-lactam susceptibility testing with a well-defined collection of Enterobacteriaceae and Pseudomonas aeruginosa strains in Spain.

Authors:  Rafael Cantón; Elena Loza; María Del Carmen Conejo; Fernando Baquero; Luis Martínez-Martínez
Journal:  J Clin Microbiol       Date:  2003-05       Impact factor: 5.948

10.  Evaluation of the Vitek 2 ID-GNB assay for identification of members of the family Enterobacteriaceae and other nonenteric gram-negative bacilli and comparison with the Vitek GNI+ card.

Authors:  Caroline M O'Hara; J Michael Miller
Journal:  J Clin Microbiol       Date:  2003-05       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.