Literature DB >> 1295766

Comparison of the autoSCAN-W/A and Vitek Automicrobic systems for identification and susceptibility testing of bacteria.

M R Visser1, L Bogaards, M Rozenberg-Arska, J Verhoef.   

Abstract

The identification and susceptibility testing of bacteria by the autoSCAN-W/A rapid panels and Vitek Automicrobic systems were compared. A total of 291 clinical isolates, including 207 members of the Enterobacteriaceae, 41 nonfermentative gram-negative bacilli, 31 Staphylococcus aureus strains and 12 Enterococcus faecalis strains, were tested. autoSCAN-W/A and Vitek correctly identified 93% and 94% respectively of the Enterobacteriaceae, the identification in an additional 2% and 5% of strains respectively being reported as correct with a low probability. autoSCAN-W/A reported all identification results within 2 h after inoculation, whereas Vitek reported the identification results for the majority of gram-negative bacilli between 4 h and 6 h after inoculation. autoSCAN-W/A and Vitek reported 81% and 74% of MIC results respectively after 3-6 h incubation. The rates of very major susceptibility errors were 0.4% and 0.4% for autoSCAN-W/A and Vitek respectively, the rates of major errors 0.4% and 1% respectively, and the rates of minor errors 4% and 3% respectively. Six of 30 Pseudomonas aeruginosa strains failed to grow sufficiently for susceptibility testing in the autoSCAN-W/A system, and four Xanthomonas maltophilia strains had insufficient growth for susceptibility testing in both systems. The majority of results of susceptibility testing of nonfermentative gram-negative bacilli were reported more than 6 h after inoculation. Both systems were reliable and easy to operate, and gave accurate results for common clinical isolates.

Entities:  

Mesh:

Year:  1992        PMID: 1295766     DOI: 10.1007/bf01967786

Source DB:  PubMed          Journal:  Eur J Clin Microbiol Infect Dis        ISSN: 0934-9723            Impact factor:   3.267


  4 in total

1.  Evaluation of MicroScan Rapid Pos Combo panels for identification of staphylococci.

Authors:  L Stoakes; B C Schieven; E Ofori; P Ewan; R Lannigan; Z Hussain
Journal:  J Clin Microbiol       Date:  1992-01       Impact factor: 5.948

2.  Comparison of the autoSCAN-W/A rapid bacterial identification system and the Vitek AutoMicrobic system for identification of gram-negative bacilli.

Authors:  M A Pfaller; D Sahm; C O'Hara; C Ciaglia; M Yu; N Yamane; G Scharnweber; D Rhoden
Journal:  J Clin Microbiol       Date:  1991-07       Impact factor: 5.948

3.  Evaluation of autoSCAN-W/A automated microbiology system for the identification of non-glucose-fermenting gram-negative bacilli.

Authors:  F C Tenover; T S Mizuki; L G Carlson
Journal:  J Clin Microbiol       Date:  1990-07       Impact factor: 5.948

4.  Comparative in vitro antibacterial activity of sparfloxacin (AT-4140; RP 64206), a new quinolone.

Authors:  M R Visser; M Rozenberg-Arska; H Beumer; I M Hoepelman; J Verhoef
Journal:  Antimicrob Agents Chemother       Date:  1991-05       Impact factor: 5.191

  4 in total
  16 in total

1.  Evaluation of the Wider system, a new computer-assisted image-processing device for bacterial identification and susceptibility testing.

Authors:  R Cantón; M Pérez-Vázquez; A Oliver; B Sánchez Del Saz; M O Gutiérrez; M Martínez-Ferrer; F Baquero
Journal:  J Clin Microbiol       Date:  2000-04       Impact factor: 5.948

2.  Particular biochemical profiles for enterohemorrhagic Escherichia coli O157:H7 isolates on the ID 32E system.

Authors:  A Leclercq; B Lambert; D Pierard; J Mahillon
Journal:  J Clin Microbiol       Date:  2001-03       Impact factor: 5.948

3.  Ability of the MicroScan rapid gram-negative ID type 3 panel to identify nonenteric glucose-fermenting and nonfermenting gram-negative bacilli.

Authors:  Caroline M O'Hara; J Michael Miller
Journal:  J Clin Microbiol       Date:  2002-10       Impact factor: 5.948

4.  Direct antimicrobial susceptibility testing of gram-negative bacilli in blood cultures by an electrochemical method.

Authors:  A H Huang; J J Wu; Y M Weng; H C Ding; T C Chang
Journal:  J Clin Microbiol       Date:  1998-10       Impact factor: 5.948

Review 5.  Use of enzyme tests in characterization and identification of aerobic and facultatively anaerobic gram-positive cocci.

Authors:  S Bascomb; M Manafi
Journal:  Clin Microbiol Rev       Date:  1998-04       Impact factor: 26.132

6.  Comparison of Crystal Enteric/Nonfermenter system, API 20E system, and Vitek AutoMicrobic system for identification of gram-negative bacilli.

Authors:  A Robinson; Y S McCarter; J Tetreault
Journal:  J Clin Microbiol       Date:  1995-02       Impact factor: 5.948

7.  Effect of clavulanic acid on the anti-pseudomonal activity of ticarcillin.

Authors:  M J Haverkorn
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1994-08       Impact factor: 3.267

8.  Parallel comparison of accuracy of API 20E, Vitek GNI, MicroScan Walk/Away Rapid ID, and Becton Dickinson Cobas Micro ID-E/NF for identification of members of the family Enterobacteriaceae and common gram-negative, non-glucose-fermenting bacilli.

Authors:  C M O'Hara; F C Tenover; J M Miller
Journal:  J Clin Microbiol       Date:  1993-12       Impact factor: 5.948

9.  Comparison of Vitek and Cobas Micro systems with a semiautomated conventional microsystem for identification and susceptibility testing of gram negative bacilli.

Authors:  A M Simoons-Smit; D M Maclaren
Journal:  J Clin Pathol       Date:  1994-01       Impact factor: 3.411

10.  Accuracy of four commercial systems for identification of Burkholderia cepacia and other gram-negative nonfermenting bacilli recovered from patients with cystic fibrosis.

Authors:  D L Kiska; A Kerr; M C Jones; J A Caracciolo; B Eskridge; M Jordan; S Miller; D Hughes; N King; P H Gilligan
Journal:  J Clin Microbiol       Date:  1996-04       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.