Literature DB >> 11516543

Temporal and spatial evaluation of lesion reparative responses following superthreshold exposure of rat lung to pulsed ultrasound.

J F Zachary1, L A Frizzell, K S Norrell, J P Blue, R J Miller, W D O'Brien.   

Abstract

This study characterized the reparative responses in rat lung. Forty-five adult female rats were exposed at two sites over the left lung to 3.1-MHz superthreshold pulsed ultrasound. The repair of lung lesions was evaluated from 0 through 44 days postexposure. Macroscopic lesions at 0 days postexposure were large bright red ellipses of hemorrhage. By 1 and 3 days postexposure, lesions were the same size and dark red to red-black, but, by 3 days postexposure, lesions had a raised surface appearance. From 5 to 10 days postexposure, lesions grew smaller in size, progressed from red-gray to yellow-brown, and retained a raised surface appearance. From 13 through 44 days postexposure, lesions gradually decreased in size, had a faint yellow-brown discoloration, and gradually lost the raised surface appearance. By 37 and 44 days postexposure, lung returned to near normal morphology, but had small areas of light yellow-brown discoloration in the areas where lung was exposed. Microscopic lesions at 0 and 1 days postexposure were areas of acute alveolar hemorrhage. By 3 days postexposure, lesions had loss of alveolar erythrocytes and the formation of hemoglobin crystals. From 5 through 44 days postexposure, iron in degraded erythrocytes was processed to hemosiderin and was negligible in quantity at 44 days postexposure. The proliferation of resident cells (likely alveolar epithelial cells, fibroblasts and endothelial cells) and the infiltration of inflammatory cells in lesions declined in intensity as the lesions aged and was minimal by 44 days postexposure. Under the superthreshold exposure conditions described, lesions induced by ultrasound do not seem to have long-term residual effects in lung.

Entities:  

Mesh:

Year:  2001        PMID: 11516543     DOI: 10.1016/s0301-5629(01)00375-1

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  12 in total

1.  Forced wave motion with internal and boundary damping.

Authors:  Tobias Louw; Scott Whitney; Anu Subramanian; Hendrik Viljoen
Journal:  J Appl Phys       Date:  2012-01-06       Impact factor: 2.546

2.  Vascular lesions and s-thrombomodulin concentrations from auricular arteries of rabbits infused with microbubble contrast agent and exposed to pulsed ultrasound.

Authors:  James F Zachary; James P Blue; Rita J Miller; William D O'Brien
Journal:  Ultrasound Med Biol       Date:  2006-11       Impact factor: 2.998

3.  Threshold estimation of ultrasound-induced lung hemorrhage in adult rabbits and comparison of thresholds in mice, rats, rabbits and pigs.

Authors:  William D O'Brien; Yan Yang; Douglas G Simpson; Leon A Frizzell; Rita J Miller; James P Blue; James F Zachary
Journal:  Ultrasound Med Biol       Date:  2006-11       Impact factor: 2.998

4.  Lesions of ultrasound-induced lung hemorrhage are not consistent with thermal injury.

Authors:  James F Zachary; James P Blue; Rita J Miller; Brian J Ricconi; J Gary Eden; William D O'Brien
Journal:  Ultrasound Med Biol       Date:  2006-11       Impact factor: 2.998

Review 5.  Ultrasound-biophysics mechanisms.

Authors:  William D O'Brien
Journal:  Prog Biophys Mol Biol       Date:  2006-08-08       Impact factor: 3.667

6.  Evaluation of the threshold for lung hemorrhage by diagnostic ultrasound and a proposed new safety index.

Authors:  Charles C Church; William D O'Brien
Journal:  Ultrasound Med Biol       Date:  2007-03-26       Impact factor: 2.998

7.  Contrast ultrasound imaging of the aorta alters vascular morphology and circulating von Willebrand factor in hypercholesterolemic rabbits.

Authors:  Brendon W Smith; Douglas G Simpson; Sandhya Sarwate; Rita J Miller; James P Blue; Alexander Haak; William D O'Brien; John W Erdman
Journal:  J Ultrasound Med       Date:  2012-05       Impact factor: 2.153

8.  Superthreshold behavior of ultrasound-induced lung hemorrhage in adult rats: role of pulse repetition frequency and pulse duration.

Authors:  William D O'Brien; Douglas G Simpson; Leon A Frizzell; James F Zachary
Journal:  J Ultrasound Med       Date:  2006-07       Impact factor: 2.153

9.  Ultrasonic imaging: safety considerations.

Authors:  Gail Ter Haar
Journal:  Interface Focus       Date:  2011-05-25       Impact factor: 3.906

10.  Contrast Ultrasound Imaging Does Not Affect Heat Shock Protein 70 Expression in Cholesterol-Fed Rabbit Aorta.

Authors:  Brendon W Smith; Douglas G Simpson; Rita J Miller; John W Erdman; William D O'Brien
Journal:  J Ultrasound Med       Date:  2015-07       Impact factor: 2.153

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.