| Literature DB >> 11484787 |
Abstract
This paper describes the construction of an adult male voxel model named "Golem" intended to be used for Monte Carlo simulations to calculate dosimetric quantities for radiation protection considerations. The model was segmented from whole-body medical image data of a living person who was 38 years old and had external dimensions close to those of the ICRP Reference Man. The segmentation process using dedicated image processing hard- and software is described and the resulting model is characterised with respect to weight and height of the total body, organ and tissue masses and red bone marrow distribution. A comparison with the respective data for ICRP Reference Man and three further voxel models is presented. Golem was found to agree reasonably well with Reference Man, so that he can be used for the assessment of "representative" body doses.Entities:
Mesh:
Year: 2001 PMID: 11484787 DOI: 10.1007/s004110100094
Source DB: PubMed Journal: Radiat Environ Biophys ISSN: 0301-634X Impact factor: 1.925