Literature DB >> 11469262

FreeStyle: a small-volume electrochemical glucose sensor for home blood glucose testing.

B Feldman1, G McGarraugh, A Heller, N Bohannon, J Skyler, E DeLeeuw, D Clarke.   

Abstract

FreeStyle accurately measures the concentration of glucose in a 300-nL volume of capillary blood obtained with significantly reduced pain from the forearm where the density of capillaries is much lower than in the fingertips. The readings are independent of temperature, of altitude (O2 pressure) and of hematocrit in the 0%-60% range. At their physiological levels, none of the often interfering constituents of blood affect the readings.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11469262     DOI: 10.1089/15209150050025177

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  9 in total

1.  Numerical simulation of the effect of rate of change of glucose on measurement error of continuous glucose monitors.

Authors:  Marc B Taub; Thomas A Peyser; J Erik Rosenquist
Journal:  J Diabetes Sci Technol       Date:  2007-09

2.  SPCE based glucose sensor employing novel thermostable glucose dehydrogenase, FADGDH: blood glucose measurement with 150nL sample in one second.

Authors:  Hideaki Yamaoka; Koji Sode
Journal:  J Diabetes Sci Technol       Date:  2007-01

3.  Periodic extraction of interstitial fluid from the site of subcutaneous insulin infusion for the measurement of glucose: a novel single-port technique for the treatment of type 1 diabetes patients.

Authors:  Werner Regittnig; Stefan Lindpointner; Stefan Korsatko; Dina Tutkur; Manfred Bodenlenz; Thomas R Pieber
Journal:  Diabetes Technol Ther       Date:  2012-11-05       Impact factor: 6.118

4.  Methods for measuring agreement: glucose levels in gingival crevice blood.

Authors:  Hans-Peter Müller; Ebrahim Behbehani
Journal:  Clin Oral Investig       Date:  2005-01-06       Impact factor: 3.573

5.  Hindered Diffusion of Oligosaccharides in High Strength Poly(ethylene glycol)/Poly(acrylic acid) Interpenetrating Network Hydrogels: Hydrodynamic Versus Obstruction Models.

Authors:  Dale J Waters; Curtis W Frank
Journal:  Polymer (Guildf)       Date:  2009-12-10       Impact factor: 4.430

6.  FreeStyle Lite--a blood glucose meter that requires no coding.

Authors:  Shridhara Alva
Journal:  J Diabetes Sci Technol       Date:  2008-07

7.  FreeStyle Mini blood glucose results are accurate and suitable for use in glycemic clamp protocols.

Authors:  Ohad Cohen; Sigal Shaklai; Ephraim Gabis; Michael A Pani
Journal:  J Diabetes Sci Technol       Date:  2008-09

8.  A low perfusion rate microreactor for continuous monitoring of enzyme characteristics: application to glucose oxidase.

Authors:  G A Posthuma-Trumpie; K Venema; W J H van Berkel; J Korf
Journal:  Anal Bioanal Chem       Date:  2007-10-02       Impact factor: 4.142

9.  Acceptability of the FreeStyle Libre Flash Glucose Monitoring System: The Experience of Young Patients With Type 1 Diabetes.

Authors:  Ayman A Al Hayek; Asirvatham A Robert; Mohamed A Al Dawish
Journal:  Clin Med Insights Endocrinol Diabetes       Date:  2020-03-16
  9 in total