Literature DB >> 19888376

SPCE based glucose sensor employing novel thermostable glucose dehydrogenase, FADGDH: blood glucose measurement with 150nL sample in one second.

Hideaki Yamaoka1, Koji Sode.   

Abstract

BACKGROUND: Self-monitoring of blood glucose (SMBG) is an important component of the modern therapy for diabetes mellitus. Thanks to the current progress in electronics and sensor fabrication technology, both the time and the blood sample volume required for the measurement have decreased drastically. However, devices that work with an even smaller sample volume and a shorter measurement time are in demand.
METHODS: A disposable glucose sensor that works with an ultra-small sample volume was developed employing the novel thermostable glucose-dehydrogenase (FADGDH) complex composed of a catalytic subunit, an electron transfer subunit (cytochrome c), and a small subunit. The electrode is a screen-printed carbon electrode (SPCE), and hexaammineruthenium (III) chloride (Ru complex) is utilized as the electron mediator. A disposable enzyme sensor was constructed by depositing the FADGDH complex and Ru complex onto the SPCE, and the sensor performance was evaluated.
RESULTS: Whole-blood glucose can be measured within 1 sec using this enzyme sensor and a 150-nL whole-blood sample, with high precision (>0.99br>) and high reproducibility (CV<0.45%br>) within the glucose concentration range of 0-533 mg/dL. The sensor reading was stable for more than 60 days even at 70 degrees C.
CONCLUSIONS: The simplicity of the construction and the high precision of this FADGDH-based glucose biosensor makes it an alternative to previously reported commercially available glucose sensors. Especially the sample volume of 150 nL and the 1-sec measurement time are the highest specifications in the world for currently available glucose sensors designed for the SMBG.

Entities:  

Keywords:  catalytic; glucose; glucose-dehydrogenase (FADGDH); recombinant; sensor

Year:  2007        PMID: 19888376      PMCID: PMC2769609          DOI: 10.1177/193229680700100105

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  17 in total

1.  FreeStyle: a small-volume electrochemical glucose sensor for home blood glucose testing.

Authors:  B Feldman; G McGarraugh; A Heller; N Bohannon; J Skyler; E DeLeeuw; D Clarke
Journal:  Diabetes Technol Ther       Date:  2000       Impact factor: 6.118

2.  [Self-monitoring of blood glucose].

Authors:  M Tominaga
Journal:  Rinsho Byori       Date:  2001-05

3.  Essential role of the small subunit of thermostable glucose dehydrogenase from Burkholderia cepacia.

Authors:  Hideaki Yamaoka; Stefano Ferri; Masako Fujikawa; Koji Sode
Journal:  Biotechnol Lett       Date:  2004-11       Impact factor: 2.461

Review 4.  Self-monitoring of blood glucose, as a means of self-management.

Authors:  Y Ikeda; A Tsuruoka
Journal:  Diabetes Res Clin Pract       Date:  1994-10       Impact factor: 5.602

5.  Cloning and functional expression of glucose dehydrogenase complex of Burkholderia cepacia in Escherichia coli.

Authors:  Taiki Tsuya; Stefano Ferri; Masako Fujikawa; Hideaki Yamaoka; Koji Sode
Journal:  J Biotechnol       Date:  2005-12-06       Impact factor: 3.307

6.  Evaluation of One Touch HORIZON--a highly affordable glucose monitor.

Authors:  V Mohan; R Deepa; A K Shefali; S Poongothai; M Monica; K Karkuzhali
Journal:  J Assoc Physicians India       Date:  2004-10

Review 7.  Monitoring glycemic control: the importance of self-monitoring of blood glucose.

Authors:  Eric Renard
Journal:  Am J Med       Date:  2005-09       Impact factor: 4.965

8.  Self-monitoring of blood glucose. American Diabetes Association.

Authors: 
Journal:  Diabetes Care       Date:  1985 Sep-Oct       Impact factor: 19.112

9.  Cloning and expression of the gene encoding catalytic subunit of thermostable glucose dehydrogenase from Burkholderia cepacia in Escherichia coli.

Authors:  Ken Inose; Masako Fujikawa; Tomohiko Yamazaki; Katsuhiro Kojima; Koji Sode
Journal:  Biochim Biophys Acta       Date:  2003-02-21

10.  Comparison of five glucose meters for self-monitoring of blood glucose by diabetic patients.

Authors:  R A Gifford-Jorgensen; J Borchert; R Hassanein; L Tilzer; G A Eaks; W V Moore
Journal:  Diabetes Care       Date:  1986 Jan-Feb       Impact factor: 19.112

View more
  1 in total

1.  Mediator Preference of Two Different FAD-Dependent Glucose Dehydrogenases Employed in Disposable Enzyme Glucose Sensors.

Authors:  Noya Loew; Wakako Tsugawa; Daichi Nagae; Katsuhiro Kojima; Koji Sode
Journal:  Sensors (Basel)       Date:  2017-11-16       Impact factor: 3.576