Abstract

Current treatment regiments for individuals depending on exogenous insulin are based on measurements of blood glucose obtained through painful finger sticks. The shift to minimal or noninvasive continuous glucose monitoring primarily involves a shift from blood glucose measurements to devices measuring subcutaneous interstitial fluid (ISF) glucose. As the development of these devices progresses, details of the dynamic relationship between blood glucose and interstitial glucose dynamics need to be firmly established. This is a challenging task insofar as direct measures of ISF glucose are not readily available. The current article investigated the dynamic relationship between plasma and ISF glucose using a model-based approach. A two-compartment model system previously validated on data obtained with the MiniMed Continuous Glucose Monitoring System (CGMS) is reviewed and predictions from the original two-compartment model were confirmed using new data analysis of glucose dynamics in plasma and hindlimb lymph (lymph is derived from ISF) in the anesthetized dog. From these data sets, the time delay between plasma and ISF glucose in dogs was established (5-12 minutes) and a simulation study was performed to estimate the errors introduced if ISF is taken as a surrogate for blood. From the simulation study, the error component resulting from the differences in plasma and ISF glucose was estimated to be < 6% during normal day-to-day use in an individual with diabetes (error component calculated as the standard deviation of the ISF/plasma glucose differences under conditions where the maximal time delay was used). This difference is most likely within the variance between arterial and venous blood glucose. We conclude that the differences between plasma and ISF glucose will not be a significant obstacle in advancing the use of ISF as an alternative to blood glucose measurements.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11467349     DOI: 10.1089/15209150050194332

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  48 in total

1.  Use of subcutaneous interstitial fluid glucose to estimate blood glucose: revisiting delay and sensor offset.

Authors:  Kerstin Rebrin; Norman F Sheppard; Garry M Steil
Journal:  J Diabetes Sci Technol       Date:  2010-09-01

Review 2.  A tale of two compartments: interstitial versus blood glucose monitoring.

Authors:  Eda Cengiz; William V Tamborlane
Journal:  Diabetes Technol Ther       Date:  2009-06       Impact factor: 6.118

3.  Graphical and numerical evaluation of continuous glucose sensing time lag.

Authors:  Boris P Kovatchev; Devin Shields; Marc Breton
Journal:  Diabetes Technol Ther       Date:  2009-03       Impact factor: 6.118

4.  Recent advances in continuous glucose monitoring: biocompatibility of glucose sensors for implantation in subcutis.

Authors:  Peter H Kvist; Henrik E Jensen
Journal:  J Diabetes Sci Technol       Date:  2007-09

5.  Numerical simulation of the effect of rate of change of glucose on measurement error of continuous glucose monitors.

Authors:  Marc B Taub; Thomas A Peyser; J Erik Rosenquist
Journal:  J Diabetes Sci Technol       Date:  2007-09

6.  Evaluation of a novel continuous glucose measurement device in patients with diabetes mellitus across the glycemic range.

Authors:  Linda Morrow; Marcus Hompesch; Ann M Tideman; Jennifer Matson; Nancy Dunne; Scott Pardo; Joan L Parkes; Holly C Schachner; David A Simmons
Journal:  J Diabetes Sci Technol       Date:  2011-07-01

Review 7.  Delays in minimally invasive continuous glucose monitoring devices: a review of current technology.

Authors:  D Barry Keenan; John J Mastrototaro; Gayane Voskanyan; Garry M Steil
Journal:  J Diabetes Sci Technol       Date:  2009-09-01

8.  Is the masked continuous glucose monitoring system clinically useful for predicting hemoglobin A1C in type 1 diabetes?

Authors:  Elizabeth Duran-Valdez; Mark R Burge; Paula Broderick; Lynda Shey; Virginia Valentine; Ronald Schrader; David S Schade
Journal:  Diabetes Technol Ther       Date:  2014-05       Impact factor: 6.118

9.  Assessment of a Noninvasive Chronic Glucose Monitoring System in Euglycemic and Diabetic Swine (Sus scrofa).

Authors:  Rebecca A Ober; Gail E Geist
Journal:  J Am Assoc Lab Anim Sci       Date:  2020-04-13       Impact factor: 1.232

10.  Markers of glycemic control in the mouse: comparisons of 6-h- and overnight-fasted blood glucoses to Hb A1c.

Authors:  Byoung Geun Han; Chuan-Ming Hao; Elena E Tchekneva; Ying-Ying Wang; Chieh Allen Lee; Benyamin Ebrahim; Raymond C Harris; Timothy S Kern; David H Wasserman; Matthew D Breyer; Zhonghua Qi
Journal:  Am J Physiol Endocrinol Metab       Date:  2008-07-29       Impact factor: 4.310

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.