Literature DB >> 11459599

Avoidance of radiation injuries from medical interventional procedures.

J Valentin.   

Abstract

Interventional radiology (fluoroscopically-guided) techniques are being used by an increasing number of clinicians not adequately trained in radiation safety or radiobiology. Many of these interventionists are not aware of the potential for injury from these procedures or the simple methods for decreasing their incidence. Many patients are not being counselled on the radiation risks, nor followed up when radiation doses from difficult procedures may lead to injury. Some patients are suffering radiation-induced skin injuries and younger patients may face an increased risk of future cancer. Interventionists are having their practice limited or suffering injury, and are exposing their staff to high doses. In some interventional procedures, skin doses to patients approach those experienced in some cancer radiotherapy fractions. Radiation-induced skin injuries are occurring in patients due to the use of inappropriate equipment and, more often, poor operational technique. Injuries to physicians and staff performing interventional procedures have also been observed. Acute radiation doses (to patients) may cause erythema at 2 Gy, cataract at 2 Gy, permanent epilation at 7 Gy, and delayed skin necrosis at 12 Gy. Protracted (occupational) exposures to the eye may cause cataract at 4 Gy if the dose is received in less than 3 months, at 5.5 Gy if received over a period exceeding 3 months. Practical actions to control dose to the patient and to the staff are listed. The absorbed dose to the patient in the area of skin that receives the maximum dose is of priority concern. Each local clinical protocol should include, for each type of interventional procedure, a statement on the cumulative skin doses and skin sites associated with the various parts of the procedure. Interventionists should be trained to use information on skin dose and on practical techniques to control dose. Maximum cumulative absorbed doses that appear to approach or exceed 1 Gy (for procedures that may be repeated) or 3 Gy (for any procedure) should be recorded in the patient record, and there should be a patient follow-up procedure for such cases. Patients should be counselled if there is a significant risk of radiation-induced injury, and the patient's personal physician should be informed of the possibility of radiation effects. Training in radiological protection for patients and staff should be an integral part of the education for those using interventional techniques. All interventionists should audit and review the outcomes of their procedures for radiation injury. Risks and benefits, including radiation risks, should be taken into account when new interventional techniques are introduced.A concluding list of recommendations is given. Annexes list procedures, patient and staff doses, a sample local clinical protocol, dose quantities used, and a procurement checklist.

Entities:  

Mesh:

Year:  2000        PMID: 11459599     DOI: 10.1016/S0146-6453(01)00004-5

Source DB:  PubMed          Journal:  Ann ICRP        ISSN: 0146-6453


  107 in total

1.  Radiation-induced temporary hair loss as a radiation damage only occurring in patients who had the combination of MDCT and DSA.

Authors:  Yoshimasa Imanishi; Atsushi Fukui; Hiroshi Niimi; Daisuke Itoh; Kyouko Nozaki; Shunsuke Nakaji; Kumiko Ishizuka; Hitoshi Tabata; Yu Furuya; Masahiko Uzura; Hideto Takahama; Suzuo Hashizume; Shiro Arima; Yasuo Nakajima
Journal:  Eur Radiol       Date:  2004-09-04       Impact factor: 5.315

Review 2.  Exposing the thyroid to radiation: a review of its current extent, risks, and implications.

Authors:  Bridget Sinnott; Elaine Ron; Arthur B Schneider
Journal:  Endocr Rev       Date:  2010-07-21       Impact factor: 19.871

3.  X-ray dose from pediatric cardiac catheterization: a comparison of materials and methods for measurement or calculation.

Authors:  Brent Herron; John Strain; Thomas Fagan; Linda Wright; Heather Shockley
Journal:  Pediatr Cardiol       Date:  2010-08-10       Impact factor: 1.655

4.  Risk of deterministic effects during endovascular aortic stent graft implantation.

Authors:  D Kuhelj; U Zdesar; V Jevtic; D Skrk; G Omahen; D Zontar; M Surlan; M Glusic; P Popovic; I J Kocijancic; V Salapura
Journal:  Br J Radiol       Date:  2010-11       Impact factor: 3.039

5.  3D cerebral angiography: radiation dose comparison with digital subtraction angiography.

Authors:  Beth A Schueler; David F Kallmes; Harry J Cloft
Journal:  AJNR Am J Neuroradiol       Date:  2005-09       Impact factor: 3.825

6.  Dose measurement on both patients and operators during neurointerventional procedures using photoluminescence glass dosimeters.

Authors:  T Moritake; Y Matsumaru; T Takigawa; K Nishizawa; A Matsumura; K Tsuboi
Journal:  AJNR Am J Neuroradiol       Date:  2008-08-21       Impact factor: 3.825

7.  Radiation exposure benefit of a lead cap in invasive cardiology.

Authors:  E Kuon; J Birkel; M Schmitt; J B Dahm
Journal:  Heart       Date:  2003-10       Impact factor: 5.994

8.  Radiation dose during endovascular aneurysm repair (EVAR): upgrade of an angiographic system from standard to Eco mode.

Authors:  Maria Antonella Ruffino; Marco Fronda; Andrea Discalzi; Paola Isoardi; Laura Bergamasco; Roberto Ropolo; Dorico Righi; Paolo Fonio
Journal:  Radiol Med       Date:  2018-07-23       Impact factor: 3.469

9.  Radiation dose to the brain and subsequent risk of developing brain tumors in pediatric patients undergoing interventional neuroradiology procedures.

Authors:  I Thierry-Chef; S L Simon; C E Land; D L Miller
Journal:  Radiat Res       Date:  2008-11       Impact factor: 2.841

10.  Patient Radiation Exposure During Diagnostic and Therapeutic Procedures for Intracranial Aneurysms: A Multicenter Study.

Authors:  Yon Kwon Ihn; Bum-Soo Kim; Jun Soo Byun; Sang Hyun Suh; Yoo Dong Won; Deok Hee Lee; Byung Moon Kim; Young Soo Kim; Pyong Jeon; Chang-Woo Ryu; Sang-Il Suh; Dae Seob Choi; See Sung Choi; Jin Wook Choi; Hyuk Won Chang; Jae-Wook Lee; Sang Heum Kim; Young Jun Lee; Shang Hun Shin; Soo Mee Lim; Woong Yoon; Hae Woong Jeong; Moon Hee Han
Journal:  Neurointervention       Date:  2016-09-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.