Literature DB >> 11413402

Diurnal variation of corneal and corneal epithelial thickness measured using optical coherence tomography.

Y Feng1, J Varikooty, T L Simpson.   

Abstract

PURPOSE: To determine the feasibility of optical coherence tomography (OCT) measurement of overnight corneal swelling and de-swelling and, specifically, to examine overnight changes in the corneal epithelium and recovery during the day.
METHODS: Ten healthy volunteers were recruited. Corneal OCT imaging was performed at 10:00 PM (baseline), 8:30 AM, and every 2 hours thereafter until 4:30 PM. Either the right or left eye was taped shut (using a gauze pad and surgical tape) until the 8:30 AM session of the next day. Measurements were made along a 1-mm strip centered on the visual axis.
RESULTS: At baseline, there were no differences in corneal or epithelial thickness between control and experimental eyes (all p > 0.05). Immediately after patch removal, corneal and epithelial thicknesses of patched eyes were higher than the baseline (all p < 0.05). In patched eyes, the cornea and epithelium swelled 5.5% and 8.1% overnight, respectively (p > 0.05). Two hours later, the epithelial thickness of the experimental eyes recovered to baseline level (p > 0.05), but corneal thickness did not reach to baseline level until 4 hours after patch removal. For control eyes, there were no differences compared with baseline (all p > 0.05).
CONCLUSION: Both cornea and corneal epithelium experience proportionately similar amounts of overnight swelling. Recovery of overnight swelling may be slower for the cornea than for the epithelium. OCT provides valuable information about anterior segment morphometry.

Entities:  

Mesh:

Year:  2001        PMID: 11413402     DOI: 10.1097/00003226-200107000-00008

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  24 in total

1.  Intraobserver and interobserver reproducibility in the evaluation of ultrasonic pachymetry measurements of central corneal thickness.

Authors:  S Miglior; E Albe; M Guareschi; G Mandelli; S Gomarasca; N Orzalesi
Journal:  Br J Ophthalmol       Date:  2004-02       Impact factor: 4.638

2.  Circadian variations in central corneal thickness and intraocular pressure in patients with glaucoma.

Authors:  P Fogagnolo; L Rossetti; F Mazzolani; N Orzalesi
Journal:  Br J Ophthalmol       Date:  2006-01       Impact factor: 4.638

3.  Noninvasive optical coherence tomography monitoring of structure and hydration changes of human corneas in different preservation media.

Authors:  Yicong Wu; Dominic Clarke; Aby Mathew; Ian Nicoud; Xingde Li
Journal:  J Biomed Opt       Date:  2011-02       Impact factor: 3.170

4.  Comparison of central corneal thickness measurements obtained by community optometrists to those obtained in secondary care.

Authors:  Laura Hughes; Cheng Yi Loo; Brian Hogan; Huai Ling Tan; Ling Shan Tang; Andrew J Tatham
Journal:  Eye (Lond)       Date:  2018-07-23       Impact factor: 3.775

5.  Repeatability and comparability of anterior segment biometry obtained by the Sirius and the Pentacam analyzers.

Authors:  Paola De la Parra-Colín; Manuel Garza-León; Tonatiuh Barrientos-Gutierrez
Journal:  Int Ophthalmol       Date:  2013-04-25       Impact factor: 2.031

6.  Evaluation of corneal parameters in patients with Parkinson's disease.

Authors:  Seden Demirci; Alime Gunes; Hasan Rifat Koyuncuoglu; Levent Tok; Ozlem Tok
Journal:  Neurol Sci       Date:  2016-04-07       Impact factor: 3.307

7.  Tear eicosanoids in healthy people and ocular surface disease.

Authors:  Yohannes Abere Ambaw; Cecilia Chao; Shanshan Ji; Manfred Raida; Federico Torta; Markus R Wenk; Louis Tong
Journal:  Sci Rep       Date:  2018-07-26       Impact factor: 4.379

8.  Corneal pachymetry mapping with high-speed optical coherence tomography.

Authors:  Yan Li; Raj Shekhar; David Huang
Journal:  Ophthalmology       Date:  2006-05       Impact factor: 12.079

9.  Excimer laser phototherapeutic keratectomy in eyes with anterior corneal dystrophies: preoperative and postoperative ultrasound biomicroscopic examination and short-term clinical outcomes with and without an antihyperopia treatment.

Authors:  Christopher J Rapuano
Journal:  Trans Am Ophthalmol Soc       Date:  2003

10.  Evaluation of rigid gas permeable lens fitting in keratoconic patients with optical coherence tomography.

Authors:  Amal M Elbendary; Waleed Abou Samra
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-02-08       Impact factor: 3.117

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.