Literature DB >> 11410171

Duration and frequency of every day activities in total hip patients.

M Morlock1, E Schneider, A Bluhm, M Vollmer, G Bergmann, V Müller, M Honl.   

Abstract

Little knowledge about frequency and duration of daily activities in patients after total hip arthroplasty is available. Such information is required for the definition of realistic load collectives for pre-clinical testing of prostheses. It could also be helpful for the quantitative evaluation of surgery outcome with different prosthesis types. The purpose of this study was to develop and apply a system for the determination of frequency and duration of patient activities in their habitual environment and to compare the results to a clinical outcome score (Harris hip score).A portable activity monitoring system (weight 1.6 kg including batteries) was designed using a Palm top computer, 2 inclination sensors for the thigh and calf and one goniometer positioned at the knee joint. An algorithm was developed to identify frequency and duration of the activities lying, sitting, standing, walking and stair climbing from the signals of the 3 sensors. 42 patients participated in the study and were equipped with the system in the morning at their home. Datasets of 31 patients (age 62.5+/-11.5 y) covered more than 6h (9.8 +/- 1.6 h) and were included in the analysis. Prosthesis specific data as well as the Harris hip score were collected. The most frequent patient activity was sitting (44.3% of the time), followed by standing (24.5%), walking (10.2%), lying (5.8%) and stair climbing (0.4%). The median number of steps/stairs was 6048/164. The number of step cycles representing one year in vivo use should, consequently, be increased to 1.1 million. The Harris hip score (91.4 +/- 9.8) correlated significantly with the number of stairs (r(2) = 0.26, p = 0.003) and showed a positive tendency with the number of steps per day. No differences in activity levels between prosthesis specific factors were found.

Entities:  

Mesh:

Year:  2001        PMID: 11410171     DOI: 10.1016/s0021-9290(01)00035-5

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  55 in total

1.  Biomechanics or necromechanics? Or how to interpret biomechanical studies.

Authors:  Richard A Brand
Journal:  Iowa Orthop J       Date:  2002

Review 2.  A review on diffusion of personal digital assistants in healthcare.

Authors:  Craig E Kuziemsky; Francis Laul; Raymond C Leung
Journal:  J Med Syst       Date:  2005-08       Impact factor: 4.460

3.  Semiautomated digital analysis of knee joint space width using MR images.

Authors:  Filippo Agnesi; Kimberly K Amrami; Carlo A Frigo; Kenton R Kaufman
Journal:  Skeletal Radiol       Date:  2007-01-23       Impact factor: 2.199

4.  The influence of surface topography on wear debris generation at the cement/bone interface under cyclic loading.

Authors:  Kirk A Stoffel; Dongliang T Yang; Dwayne Arola
Journal:  J Mater Sci Mater Med       Date:  2007-10-13       Impact factor: 3.896

5.  Stability and trunnion wear potential in large-diameter metal-on-metal total hips: a finite element analysis.

Authors:  Jacob M Elkins; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

6.  The 2011 ABJS Nicolas Andry Award: 'Lab'-in-a-knee: in vivo knee forces, kinematics, and contact analysis.

Authors:  Darryl D D'Lima; Shantanu Patil; Nicolai Steklov; Clifford W Colwell
Journal:  Clin Orthop Relat Res       Date:  2011-05-20       Impact factor: 4.176

7.  Experimental testing of total knee replacements with UHMW-PE inserts: impact of severe wear test conditions.

Authors:  Carmen Zietz; Joern Reinders; Jens Schwiesau; Alexander Paulus; Jan Philippe Kretzer; Thomas Grupp; Sandra Utzschneider; Rainer Bader
Journal:  J Mater Sci Mater Med       Date:  2015-02-26       Impact factor: 3.896

8.  Locking buttons increase fatigue life of locking plates in a segmental bone defect model.

Authors:  Marc Tompkins; David J Paller; Douglas C Moore; Joseph J Crisco; Richard M Terek
Journal:  Clin Orthop Relat Res       Date:  2012-10-27       Impact factor: 4.176

9.  Male gender, Charnley class C, and severity of bone defects predict the risk for aseptic loosening in the cup of ABG I hip arthroplasty.

Authors:  Jiri Gallo; Vitezslav Havranek; Jana Zapletalova; Jiri Lostak
Journal:  BMC Musculoskelet Disord       Date:  2010-10-19       Impact factor: 2.362

10.  Numerical investigations on the strain-adaptive bone remodelling in the periprosthetic femur: influence of the boundary conditions.

Authors:  Bernd-Arno Behrens; Ingo Nolte; Patrick Wefstaedt; Christina Stukenborg-Colsman; Anas Bouguecha
Journal:  Biomed Eng Online       Date:  2009-04-16       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.