Literature DB >> 9118983

Mechanomyographic responses to concentric isokinetic muscle contractions.

T K Evetovich1, T J Housh, J R Stout, G O Johnson, D B Smith, K T Ebersole.   

Abstract

The purpose of this investigation was to examine the effects of velocity of contraction on the mechanomyographic (MMG) responses to maximal concentric isokinetic leg extension movements. Eight adult males [mean (SD) age, 22.3 (1.3) years] performed maximal leg extensions on a calibrated Cybex 6000 dynamometer at velocities of 60, 120, 180, 240, 300, and 360 degrees x s(-1) x MMG responses were detected by a piezoelectric recording device placed over the vastus lateralis muscle. Intraclass reliability correlations ranged from R = 0.84 to 0.97 and from 0.90 to 0.99 for peak torque and MMG amplitude values, respectively, with no significant differences (P > 0.05) between the mean values for test versus retest at any contraction velocity. There were significant differences (P < 0.05) in peak torque at all velocities except 240 [135 (27) Nm] versus 300 [127 (27) Nm], and 300 versus 360 degrees x s(-1) [115 (37) Nm]. The mean MMG amplitude at 60 degrees x s(-1) [61 (67) mV] was significantly less (P < 0.05) than that at 360 degrees x s(-1) [452 (451) mV]. These results indicate a velocity-related dissociation between MMG amplitude and peak torque. Furthermore, it was hypothesized that the increases in MMG amplitude were due to velocity-related decreases in muscle stiffness which allowed for greater muscle fiber oscillations.

Entities:  

Mesh:

Year:  1997        PMID: 9118983     DOI: 10.1007/s004210050142

Source DB:  PubMed          Journal:  Eur J Appl Physiol Occup Physiol        ISSN: 0301-5548


  14 in total

1.  Estimation of elbow flexion force during isometric muscle contraction from mechanomyography and electromyography.

Authors:  Wonkeun Youn; Jung Kim
Journal:  Med Biol Eng Comput       Date:  2010-06-04       Impact factor: 2.602

2.  The acute effects of static stretching on peak torque, mean power output, electromyography, and mechanomyography.

Authors:  J T Cramer; T J Housh; J P Weir; G O Johnson; J W Coburn; T W Beck
Journal:  Eur J Appl Physiol       Date:  2004-12-15       Impact factor: 3.078

3.  Muscle Contraction Velocity: A Suitable Approach to Analyze the Functional Adaptations in Elite Soccer Players.

Authors:  Irineu Loturco; Lucas A Pereira; Ronaldo Kobal; Katia Kitamura; Rodrigo Ramírez-Campillo; Vinicius Zanetti; Cesar C Cal Abad; Fabio Y Nakamura
Journal:  J Sports Sci Med       Date:  2016-08-05       Impact factor: 2.988

4.  Comment on: "Assessment of Skeletal Muscle Contractile Properties by Radial Displacement: The Case for Tensiomyography".

Authors:  Pedro L Valenzuela; Guillermo Sánchez-Martínez; Elaia Torrontegi; Javier Vázquez-Carrión; Zigor Montalvo; Alejandro Lucia
Journal:  Sports Med       Date:  2019-06       Impact factor: 11.136

5.  Comparison of displacement and acceleration transducers for the characterization of mechanics of muscle and subcutaneous tissues by system identification of a mechanomyogram.

Authors:  Takanori Uchiyama; Keita Shinohara
Journal:  Med Biol Eng Comput       Date:  2012-11-03       Impact factor: 2.602

6.  Acute Effects of Static and Proprioceptive Neuromuscular Facilitation Stretching on Muscle Strength and Power Output.

Authors:  Sarah M Marek; Joel T Cramer; A Louise Fincher; Laurie L Massey; Suzanne M Dangelmaier; Sushmita Purkayastha; Kristi A Fitz; Julie Y Culbertson
Journal:  J Athl Train       Date:  2005-06       Impact factor: 2.860

7.  Electromyography and Mechanomyography Signals During Swallowing in Healthy Adults and Head and Neck Cancer Survivors.

Authors:  Gabriela Constantinescu; William Hodgetts; Dylan Scott; Kristina Kuffel; Ben King; Chris Brodt; Jana Rieger
Journal:  Dysphagia       Date:  2016-08-26       Impact factor: 3.438

8.  Whole muscle contractile parameters and thickness loss during 35-day bed rest.

Authors:  Rado Pisot; Marco V Narici; Bostjan Simunic; Maarten De Boer; Olivier Seynnes; Mihaela Jurdana; Gianni Biolo; Igor B Mekjavić
Journal:  Eur J Appl Physiol       Date:  2008-02-23       Impact factor: 3.078

9.  Mechanical behaviour of condenser microphone in mechanomyography.

Authors:  M Watakabe; K Mita; K Akataki; Y Itoh
Journal:  Med Biol Eng Comput       Date:  2001-03       Impact factor: 3.079

Review 10.  Mechanomyographic amplitude and frequency responses during dynamic muscle actions: a comprehensive review.

Authors:  Travis W Beck; Terry J Housh; Joel T Cramer; Joseph P Weir; Glen O Johnson; Jared W Coburn; Moh H Malek; Michelle Mielke
Journal:  Biomed Eng Online       Date:  2005-12-19       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.