Literature DB >> 11282105

Comparison of BD Vacutainer SST Plus Tubes with BD SST II Plus Tubes for common analytes.

V J Bush1, M R Janu, F Bathur, A Wells, A Dasgupta.   

Abstract

Serum separator tubes were introduced 25 years ago and are widely used in the clinical laboratory today for routine collection of blood. These tubes have gained widespread acceptance due to the advantage of the barrier gel that facilitates rapid separation of serum from cellular constituents of blood and thus reduces hemolysis. However, there are some limitations associated with gel tubes (i.e., gel stability and analyte incompatibilities). The serum separator BD SST tubes manufactured by BD are widely used in clinical laboratories. Recently, BD has developed a new barrier gel, which is superior to the existing gel. We studied the stability of common analytes when serum specimens were stored in the new BD SST II tubes by comparing the performance with the existing BD SST tubes. We did not observe any significant reduction in concentrations of 42 commonly ordered analytes using the new BD SST II tubes. Significant differences were noted at low serum volumes for estradiol in both tube types over time. We conclude that the new BD SST II tubes are suitable for collection of blood and storage of serum for commonly ordered laboratory tests.

Entities:  

Mesh:

Year:  2001        PMID: 11282105     DOI: 10.1016/s0009-8981(01)00396-5

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  12 in total

1.  A comparison of IgG anti-rubella activity in frozen serum stored in primary gel separation tubes or secondary tubes.

Authors:  V Ellis; A Charlett; R Bendall
Journal:  J Clin Pathol       Date:  2004-01       Impact factor: 3.411

2.  Suitability of frozen serum stored in gel separator primary sampling tubes for serological testing.

Authors:  Manuel Rosa-Fraile; Antonio Sampedro; Javier Rodríguez-Granger; Enrique Camacho; Ester Manrique
Journal:  Clin Diagn Lab Immunol       Date:  2004-01

3.  Plasma miR-221/222 Family as Novel Descriptive and Prognostic Biomarkers for Glioma.

Authors:  Rui Zhang; Bo Pang; Tao Xin; Hua Guo; Yi Xing; Shangchen Xu; Bin Feng; Bin Liu; Qi Pang
Journal:  Mol Neurobiol       Date:  2015-01-31       Impact factor: 5.590

4.  Blood collection tube-related alterations in analyte concentrations in quality control material and serum specimens.

Authors:  Raffick A R Bowen; Annie Sattayapiwat; Verena Gounden; Alan T Remaley
Journal:  Clin Biochem       Date:  2013-11-14       Impact factor: 3.281

5.  LncRNAs, MALAT1 and lnc-DC as potential biomarkers for multiple sclerosis diagnosis.

Authors:  Olfat G Shaker; Rania H Mahmoud; Omayma O Abdelaleem; Enas G Ibrahem; Abdelrahmaan A Mohamed; Othman M Zaki; Noha K Abdelghaffar; Tarek I Ahmed; Nada F Hemeda; Naglaa A Ahmed; Dina F Mansour
Journal:  Biosci Rep       Date:  2019-01-15       Impact factor: 3.840

6.  Comparison of ingesting a food bar containing whey protein and isomalto-oligosaccharides to carbohydrate on performance and recovery from an acute bout of resistance-exercise and sprint conditioning: an open label, randomized, counterbalanced, crossover pilot study.

Authors:  Tyler J Grubic; Ryan J Sowinski; Ben E Nevares; Victoria M Jenkins; Susannah L Williamson; Aimee G Reyes; Christopher Rasmussen; Mike Greenwood; Peter S Murano; Conrad P Earnest; Richard B Kreider
Journal:  J Int Soc Sports Nutr       Date:  2019-08-13       Impact factor: 5.150

7.  Dose-Response of Paraxanthine on Cognitive Function: A Double Blind, Placebo Controlled, Crossover Trial.

Authors:  Dante Xing; Choongsung Yoo; Drew Gonzalez; Victoria Jenkins; Kay Nottingham; Broderick Dickerson; Megan Leonard; Joungbo Ko; Mark Faries; Wesley Kephart; Martin Purpura; Ralf Jäger; Shawn D Wells; Ryan Sowinski; Christopher J Rasmussen; Richard B Kreider
Journal:  Nutrients       Date:  2021-12-15       Impact factor: 5.717

Review 8.  Interferences from blood collection tube components on clinical chemistry assays.

Authors:  Raffick A R Bowen; Alan T Remaley
Journal:  Biochem Med (Zagreb)       Date:  2014-02-15       Impact factor: 2.313

9.  Abnormal gel flotation in a patient with apperant pneumonia diagnosis: a case report.

Authors:  Fethullah Gerin; Dilber Coban Ramazan; Ozgur Baykan; Onder Sirikci; Goncagul Haklar
Journal:  Biochem Med (Zagreb)       Date:  2014-02-15       Impact factor: 2.313

10.  The local clinical validation of a new lithium heparin tube with a barrier: BD Vacutainer® Barricor LH Plasma tube.

Authors:  Fatma Demet Arslan; Inanc Karakoyun; Banu Isbilen Basok; Merve Zeytinli Aksit; Anil Baysoy; Yasemin Kilic Ozturk; Yusuf Adnan Guclu; Can Duman
Journal:  Biochem Med (Zagreb)       Date:  2017-08-28       Impact factor: 2.313

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.