Literature DB >> 14715572

Suitability of frozen serum stored in gel separator primary sampling tubes for serological testing.

Manuel Rosa-Fraile1, Antonio Sampedro, Javier Rodríguez-Granger, Enrique Camacho, Ester Manrique.   

Abstract

The suitability of frozen serum after storage in primary sampling tubes with a gel separator for serological enzyme-linked immunosorbent assay testing (hepatitis B virus surface antigen [HBs Ag], anti-HBs Ag, anti-Toxoplasma gondii immunoglobulin G [IgG], anti-rubella virus IgG, anti-cytomegalovirus IgM, and anti-Epstein-Barr virus IgM) was evaluated for 375 samples. No difference was found among test results using fresh or stored frozen serum

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14715572      PMCID: PMC321361          DOI: 10.1128/cdli.11.1.219-221.2004

Source DB:  PubMed          Journal:  Clin Diagn Lab Immunol        ISSN: 1071-412X


  8 in total

1.  Comparison of BD Vacutainer SST Plus Tubes with BD SST II Plus Tubes for common analytes.

Authors:  V J Bush; M R Janu; F Bathur; A Wells; A Dasgupta
Journal:  Clin Chim Acta       Date:  2001-04       Impact factor: 3.786

2.  [Evaluation of the analytic performance of blood collection tubes (BD Vacutainer SST) for the screening of anti-HIV, anti-HTLV, anti-HCV, anti-HBc, anti-CMV antibodies, and of HBs, P24 HIV antigens, and of alanine aminotransferase].

Authors:  E Gobin; J M Desruelle; J P Vigier
Journal:  Transfus Clin Biol       Date:  2001-02       Impact factor: 1.406

3.  Stability of therapeutic drugs in serum collected in vacutainer serum separator tubes containing a new gel (SST II).

Authors:  V Bush; J Blennerhasset; A Wells; A Dasgupta
Journal:  Ther Drug Monit       Date:  2001-06       Impact factor: 3.681

4.  Stability studies of twenty-four analytes in human plasma and serum.

Authors:  Bobby L Boyanton; Kenneth E Blick
Journal:  Clin Chem       Date:  2002-12       Impact factor: 8.327

5.  Interference due to haemolysis in routine photometric analysis--a survey.

Authors:  J Brady; N O'Leary
Journal:  Ann Clin Biochem       Date:  1998-01       Impact factor: 2.057

6.  Delay in centrifugation and measurement of serum constituents in normal subjects.

Authors:  M S Devgun
Journal:  Clin Physiol Biochem       Date:  1989

7.  A new plastic evacuated tube with plasma separator.

Authors:  M Landt; T R Wilhite; C H Smith
Journal:  J Clin Lab Anal       Date:  1995       Impact factor: 2.352

8.  Stability of cytomegalovirus antibodies in plasma during prolonged storage of blood components.

Authors:  A Pappin; M Grissom; W Mackay; Y Huang; R Yomtovian
Journal:  Clin Diagn Lab Immunol       Date:  1995-01
  8 in total
  4 in total

1.  Response to third rubella vaccine dose.

Authors:  Lotta Siira; Hanne Nøkleby; Regine Barlinn; Øystein R Riise; Ingeborg S Aaberge; Susanne G Dudman
Journal:  Hum Vaccin Immunother       Date:  2018-06-21       Impact factor: 3.452

Review 2.  Socioeconomic position and inflammatory and immune biomarkers of cardiovascular disease: applications to the Panel Study of Income Dynamics.

Authors:  Allison E Aiello; George A Kaplan
Journal:  Biodemography Soc Biol       Date:  2009

Review 3.  Bio-banking in microbiology: from sample collection to epidemiology, diagnosis and research.

Authors:  Paolo De Paoli
Journal:  FEMS Microbiol Rev       Date:  2005-02-26       Impact factor: 16.408

4.  Application of newly developed SARS-CoV2 serology test along with real-time PCR for early detection in health care workers and on-time plasma donation.

Authors:  Mohammad Sadegh Soltani-Zangbar; Leili Aghebati-Maleki; Mahsa Hajivalili; Mostafa Haji-Fatahaliha; Roza Motavalli; Ata Mahmoodpoor; Hossein Samadi Kafil; Sara Farhang; Ramin Pourakbari; Farhad Jadidi-Niaragh; Leila Roshangar; Javad Ahmadian Heris; Amin Kamrani; Homayoon Siahmansouri; Maryam Hosseini; Abolfazl Miahipour; Oldouz Shareghi-Oskoue; Forough Parhizkar; Mehdi Yousefi
Journal:  Gene Rep       Date:  2021-04-13
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.