Literature DB >> 11219601

A systematic analysis of factors which may impact upon tomographic perfusion imaging measurements: implications for the use of Tc-99m sestamibi in acute myocardial infarction.

A K Das1, M K Oconnor, R J Gibbons, E L Ritman, T F Christian.   

Abstract

BACKGROUND: The use of acute Tc-99m sestamibi imaging has provided a valuable methodology to assess myocardium at risk and collateral blood flow.
OBJECTIVE: The purpose of this study was to determine the impact of physical, physiologic, and reconstruction factors on the extent and severity of Tc-99m sestamibi images in a porcine model of coronary occlusion and reperfusion. METHODS AND
RESULTS: Eleven pigs underwent 40 min of coronary occlusion using a balloon catheter followed by reperfusion. Radiolabeled microspheres were injected during occlusion for blood flow determination and 20-30 mCi of Tc-99m sestamibi was injected intravenously for cardiac imaging. Each animal underwent four modes of gamma camera imaging: a cardiac and respiratory gated SPECT study, an ungated SPECT study, a post-mortem SPECT study and an ex-situ study where the heart was sliced into five short axis slices and directly imaged. All animals had extensive wall motion abnormalities at the time of imaging. Myocardial risk area by ex-situ imaging was 32 +/- 9% LV and did not significantly change with the addition of a chest cavity and tomographic reconstruction (post-mortem and gated imaging) or cardiac and respiratory motion (ungated imaging). Defect severity was significantly underestimated with the addition of a chest cavity and tomographic reconstruction but was unaltered by cardiac and respiratory motion.
CONCLUSIONS: The assessment of risk area acutely by SPECT Tc-99m sestamibi imaging is unaffected by cardiac motion obviating the necessity for gated imaging. Estimated defect severity (which has been used as a measure of collateral flow) is significantly reduced by the chest wall and tomographic acquisition and reconstruction suggesting a role for scatter and attenuation algorithms for this measure.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11219601     DOI: 10.1023/a:1026508429309

Source DB:  PubMed          Journal:  Int J Card Imaging        ISSN: 0167-9899


  28 in total

1.  Technetium-99m MIBI to assess coronary collateral flow during acute myocardial infarction in two closed-chest animal models.

Authors:  T F Christian; M K O'Connor; R S Schwartz; R J Gibbons; E L Ritman
Journal:  J Nucl Med       Date:  1997-12       Impact factor: 10.057

Review 2.  Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms.

Authors:  N B Schiller; P M Shah; M Crawford; A DeMaria; R Devereux; H Feigenbaum; H Gutgesell; N Reichek; D Sahn; I Schnittger
Journal:  J Am Soc Echocardiogr       Date:  1989 Sep-Oct       Impact factor: 5.251

3.  Enhanced accuracy of defect detection by myocardial single-photon emission computed tomography with attenuation correction with gadolinium 153 line sources: evaluation with a cardiac phantom.

Authors:  Z X He; M D Scarlett; J J Mahmarian; M S Verani
Journal:  J Nucl Cardiol       Date:  1997 May-Jun       Impact factor: 5.952

4.  Total and regional coronary blood flow measured by radioactive microspheres in conscious and anesthetized dogs.

Authors:  R J Domenech; J I Hoffman; M I Noble; K B Saunders; J R Henson; S Subijanto
Journal:  Circ Res       Date:  1969-11       Impact factor: 17.367

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  Comparing methods of measurement: why plotting difference against standard method is misleading.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1995-10-21       Impact factor: 79.321

Review 7.  Quantitative single-photon emission computed tomography: basics and clinical considerations.

Authors:  B M Tsui; X Zhao; E C Frey; W H McCartney
Journal:  Semin Nucl Med       Date:  1994-01       Impact factor: 4.446

8.  Influence of cardiac and respiratory motion on tomographic reconstructions of the heart: implications for quantitative nuclear cardiology.

Authors:  M M Ter-Pogossian; S R Bergmann; B E Sobel
Journal:  J Comput Assist Tomogr       Date:  1982-12       Impact factor: 1.826

9.  Effect of ischemia and postischemic dysfunction on myocardial uptake of technetium-99m-labeled methoxyisobutyl isonitrile and thallium-201.

Authors:  A J Sinusas; D D Watson; J M Cannon; G A Beller
Journal:  J Am Coll Cardiol       Date:  1989-12       Impact factor: 24.094

10.  In vitro validation of a simple tomographic technique for estimation of percentage myocardium at risk using methoxyisobutyl isonitrile technetium 99m (sestamibi).

Authors:  M K O'Connor; T Hammell; R J Gibbons
Journal:  Eur J Nucl Med       Date:  1990
View more
  1 in total

1.  Acute rest perfusion imaging in high risk unstable angina: association with troponin T and clinical endpoints.

Authors:  M Hakan Dinckal; Nur Aksoy; Mehmet Aksoy; Vedat Davutoglu; Nurten Dinckal; Serdar Soydinc; Ilyas Akdemir
Journal:  Int J Cardiovasc Imaging       Date:  2003-12       Impact factor: 2.357

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.