Literature DB >> 9199257

Enhanced accuracy of defect detection by myocardial single-photon emission computed tomography with attenuation correction with gadolinium 153 line sources: evaluation with a cardiac phantom.

Z X He1, M D Scarlett, J J Mahmarian, M S Verani.   

Abstract

BACKGROUND: Photon attenuation is a major cause of artifacts on single-photon emission tomographic imaging. METHODS AND
RESULTS: To study a new method to perform photon attenuation correction (AC), we used a cardiac phantom filled with (99m)Tc and imaged it (1) without extrinsic attenuation or defects, (2) with extrinsic attenuation but without defects, (3) without extrinsic attenuation but with defects involving 10% of the myocardial volume and activity ranging from 0% to 75% of maximum, and (4) with both extrinsic attenuation and defects. Transmission and emission images acquired with a dual-head single-photon emission computed tomographic system with 153Gd line sources were processed by iterative maximum-likelihood-expectation-maximization and were evaluated both qualitatively and quantitatively. The small defects were readily identified both before and after AC. Mean count activity (percent of maximal activity) of the segments with overlying extrinsic attenuation but without defects was only 56% +/- 4% without AC but increased to 86% +/- 4% with AC (p < 0.0001). Without AC, the count activities in the defects with overlying extrinsic attenuation were lower than the actual defect activities, but AC resulted in better approximation of actual defect activities in all but the most severe (0% tracer activity) defects.
CONCLUSION: This new AC method provided an improved estimation of actual myocardial count activity. Even small defects with mild reduction in tracer activity were still identifiable after AC.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9199257     DOI: 10.1016/s1071-3581(97)90080-5

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  36 in total

1.  Optimal specificity of thallium-201 SPECT through recognition of imaging artifacts.

Authors:  E G DePuey; E V Garcia
Journal:  J Nucl Med       Date:  1989-04       Impact factor: 10.057

2.  Effects of scatter correction on the measurement of infarct size from SPECT cardiac phantom studies.

Authors:  M K O'Connor; C Caiati; T F Christian; R J Gibbons
Journal:  J Nucl Med       Date:  1995-11       Impact factor: 10.057

3.  Simultaneous transmission-emission thallium-201 cardiac SPECT: effect of attenuation correction on myocardial tracer distribution.

Authors:  E P Ficaro; J A Fessler; R J Ackermann; W L Rogers; J R Corbett; M Schwaiger
Journal:  J Nucl Med       Date:  1995-06       Impact factor: 10.057

4.  Overlying breast as cause of false-positive thallium scans.

Authors:  J Stolzenberg; J Kaminsky
Journal:  Clin Nucl Med       Date:  1978-06       Impact factor: 7.794

5.  The effect of diaphragmatic attenuation on 201Tl images.

Authors:  D G Gordon; M Pfisterer; R Williams; S Walaski; W Ashburn
Journal:  Clin Nucl Med       Date:  1979-04       Impact factor: 7.794

6.  Transmission scanning: a useful adjunct to conventional emission scanning for accurately keying isotope deposition to radiographic anatomy.

Authors:  D E Kuhl; J Hale; W L Eaton
Journal:  Radiology       Date:  1966-08       Impact factor: 11.105

7.  Prone versus supine thallium myocardial SPECT: a method to decrease artifactual inferior wall defects.

Authors:  G M Segall; M J Davis
Journal:  J Nucl Med       Date:  1989-04       Impact factor: 10.057

8.  The inconsistent pattern of thallium defects: a clue to the false positive perfusion scintigram.

Authors:  R F Dunn; L Wolff; S Wagner; E H Botvinick
Journal:  Am J Cardiol       Date:  1981-08       Impact factor: 2.778

9.  Quantitative analysis of the tomographic thallium-201 myocardial bullseye display: critical role of correcting for patient motion.

Authors:  R Eisner; A Churchwell; T Noever; D Nowak; K Cloninger; D Dunn; W Carlson; J Oates; J Jones; D Morris
Journal:  J Nucl Med       Date:  1988-01       Impact factor: 10.057

10.  Quantitative rotational thallium-201 tomography for identifying and localizing coronary artery disease.

Authors:  E E DePasquale; A C Nody; E G DePuey; E V Garcia; G Pilcher; C Bredlau; G Roubin; A Gober; A Gruentzig; P D'Amato
Journal:  Circulation       Date:  1988-02       Impact factor: 29.690

View more
  6 in total

1.  Clinical implication of down-scatter in attenuation-corrected myocardial SPECT.

Authors:  H Almquist; H Arheden; A H Arvidsson; O Pahlm; J Palmer
Journal:  J Nucl Cardiol       Date:  1999 Jul-Aug       Impact factor: 5.952

2.  Development of respiratory gated myocardial SPECT system.

Authors:  K Cho; S Kumiata; S Okada; T Kumazaki
Journal:  J Nucl Cardiol       Date:  1999 Jan-Feb       Impact factor: 5.952

3.  Assessment of geometrical distortion and activity distribution after attenuation correction: A SPECT phantom study.

Authors:  Sara Lappi; Simonetta Lazzari; Graziella Sarti; Pierluigi Pieri
Journal:  J Nucl Cardiol       Date:  2002 Sep-Oct       Impact factor: 5.952

Review 4.  Ninth annual Mario S. Verani memorial lecture : testing our tests: the evidence bar is rising. Regulatory considerations in the development of cardiac imaging agents.

Authors:  James E Udelson
Journal:  J Nucl Cardiol       Date:  2011-08       Impact factor: 5.952

5.  Impact of attenuation correction and gated acquisition in SPECT myocardial perfusion imaging: results of the multicentre SPAG (SPECT Attenuation Correction vs Gated) study.

Authors:  Dario Genovesi; Assuero Giorgetti; Alessia Gimelli; Annette Kusch; Irene D'Aragona Tagliavia; Mirta Casagranda; Giorgio Cannizzaro; Raffaele Giubbini; Francesco Bertagna; Giorgio Fagioli; Massimiliano Rossi; Annadina Romeo; Pietro Bertolaccini; Rita Bonini; Paolo Marzullo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-06-09       Impact factor: 9.236

6.  A systematic analysis of factors which may impact upon tomographic perfusion imaging measurements: implications for the use of Tc-99m sestamibi in acute myocardial infarction.

Authors:  A K Das; M K Oconnor; R J Gibbons; E L Ritman; T F Christian
Journal:  Int J Card Imaging       Date:  2000-08
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.