Literature DB >> 11212372

X-ray CT metal artifact reduction using wavelets: an application for imaging total hip prostheses.

S Zhao1, D D Robertson, G Wang, B Whiting, K T Bae.   

Abstract

Traditional computed tomography (CT) reconstructions of total joint prostheses are limited by metal artifacts from corrupted projection data. Published metal artifact reduction methods are based on the assumption that severe attenuation of X-rays by prostheses renders corresponding portions of projection data unavailable, hence the "missing" data are either avoided (in iterative reconstruction) or interpolated (in filtered backprojection with data completion; typically, with filling data "gaps" via linear functions). In this paper, we propose a wavelet-based multiresolution analysis method for metal artifact reduction, in which information is extracted from corrupted projection data. The wavelet method improves image quality by a successive interpolation in the wavelet domain. Theoretical analysis and experimental results demonstrate that the metal artifacts due to both photon starving and beam hardening can be effectively suppressed using our method. As compared to the filtered backprojection after linear interpolation, the wavelet-based reconstruction is significantly more accurate for depiction of anatomical structures, especially in the immediate neighborhood of the prostheses. This superior imaging precision is highly advantageous in geometric modeling for fitting hip prostheses.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11212372     DOI: 10.1109/42.897816

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  48 in total

1.  A pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced images.

Authors:  Oliver Watzke; Willi A Kalender
Journal:  Eur Radiol       Date:  2004-03-11       Impact factor: 5.315

2.  Development, implementation and evaluation of a dedicated metal artefact reduction method for interventional flat-detector CT.

Authors:  D Prell; W A Kalender; Y Kyriakou
Journal:  Br J Radiol       Date:  2010-09-21       Impact factor: 3.039

3.  Clinical evaluation of a newly developed method for avoiding artifacts caused by dental fillings on X-ray CT.

Authors:  Yasuo Nakae; Kiyoshi Sakamoto; Takahiro Minamoto; Toshiko Kamakura; Yuji Ogata; Mitsuhiro Matsumoto; Takeshi Johkou
Journal:  Radiol Phys Technol       Date:  2007-12-14

4.  Reduction of metallic coil artefacts in computed tomography body imaging: effects of a new single-energy metal artefact reduction algorithm.

Authors:  Masafumi Kidoh; Daisuke Utsunomiya; Osamu Ikeda; Yoshitaka Tamura; Seitaro Oda; Yoshinori Funama; Hideaki Yuki; Takeshi Nakaura; Takayuki Kawano; Toshinori Hirai; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2015-08-14       Impact factor: 5.315

5.  Preliminary study of correction of original metal artifacts due to 1-125 seeds in postimplant dosimetry for prostate permanent implant brachytherapy.

Authors:  Yutaka Takahashi; Shinichiro Mori; Takuyo Kozuka; Kotaro Gomi; Takayuki Nose; Takatoshi Tahara; Masahiko Oguchi; Takashi Yamashita
Journal:  Radiat Med       Date:  2006-02

6.  A segmentation-based method for metal artifact reduction.

Authors:  Hengyong Yu; Kai Zeng; Deepak K Bharkhada; Ge Wang; Mark T Madsen; Osama Saba; Bruno Policeni; Matthew A Howard; Wendy R K Smoker
Journal:  Acad Radiol       Date:  2007-04       Impact factor: 3.173

7.  Clinical potential of digital linear tomosynthesis imaging of total joint arthroplasty.

Authors:  Tsutomu Gomi; Hiroshi Hirano
Journal:  J Digit Imaging       Date:  2008-09       Impact factor: 4.056

8.  Computed tomographic beam-hardening artefacts: mathematical characterization and analysis.

Authors:  Hyoung Suk Park; Yong Eun Chung; Jin Keun Seo
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2015-06-13       Impact factor: 4.226

9.  Reduction of Metal Artifacts and Improvement in Dose Efficiency Using Photon-Counting Detector Computed Tomography and Tin Filtration.

Authors:  Wei Zhou; David J Bartlett; Felix E Diehn; Katrina N Glazebrook; Amy L Kotsenas; Rickey E Carter; Joel G Fletcher; Cynthia H McCollough; Shuai Leng
Journal:  Invest Radiol       Date:  2019-04       Impact factor: 6.016

10.  Metal artifact correction for x-ray computed tomography using kV and selective MV imaging.

Authors:  Meng Wu; Andreas Keil; Dragos Constantin; Josh Star-Lack; Lei Zhu; Rebecca Fahrig
Journal:  Med Phys       Date:  2014-12       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.