Literature DB >> 23090244

Setup margins and geometric uncertainties in intensity-modulated radiation therapy in treating pituitary adenomas: the experience of Lyon Sud Hospital.

B De Bari1, I Shakir Shakir, T Chekrine, L Lestrade, V Favrel.   

Abstract

PURPOSE: The authors retrospectively evaluated the setup uncertainties in Intensity-Modulated Radiation Therapy (IMRT) for pituitary adenomas and verified the margins used in daily practice (3 mm).
MATERIALS AND METHODS: Craniocaudal (CC), anteroposterior (AP) and laterolateral (LL) displacements were measured during the first 3 days of treatment and then weekly by comparing two orthogonal images obtained by an electronic system of portal imaging with Digitally Reconstructed Radiographs (DRRs). Setup Margins (SM) were defined according to the International Commission on Radiation Units (ICRU)-62 formula, the Stroom equation and the van Herk equation. The systematic (Σ) and random (σ) errors of the population were calculated as standard deviation (SD) of the population mean and the mean of SDs for every patient, respectively.
RESULTS: Twenty patients were treated by IMRT for pituitary adenomas, and a total of 231 measurements were obtained. Σ and σ were 0.6 and 1.3 mm, 0.8 and 1 mm, 1.2 and 1.5 mm in the AP, LL and CC direction, respectively. Larger setup margin was 2.4, 2.7 and 4 mm in the AP, LL and CC direction, respectively (van Herk formula).
CONCLUSIONS: IMRT is a highly sophisticated treatment technique that requires precise definition and optimisation of local setup errors and, finally, of the irradiated volumes. The role of image-guided RT in these kinds of treatments should be prospectively evaluated.

Entities:  

Mesh:

Year:  2012        PMID: 23090244     DOI: 10.1007/s11547-012-0883-9

Source DB:  PubMed          Journal:  Radiol Med        ISSN: 0033-8362            Impact factor:   3.469


  27 in total

1.  Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability.

Authors:  J C Stroom; H C de Boer; H Huizenga; A G Visser
Journal:  Int J Radiat Oncol Biol Phys       Date:  1999-03-01       Impact factor: 7.038

2.  Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 report.

Authors:  Joep C Stroom; Ben J M Heijmen
Journal:  Radiother Oncol       Date:  2002-07       Impact factor: 6.280

3.  [Normal tissue tolerance to external beam radiation therapy: eye structures].

Authors:  V Marchand; R Dendale
Journal:  Cancer Radiother       Date:  2010-07-07       Impact factor: 1.018

4.  Heavy-charged-particle radiosurgery of the pituitary gland: clinical results of 840 patients.

Authors:  R P Levy; J I Fabrikant; K A Frankel; M H Phillips; J T Lyman; J H Lawrence; C A Tobias
Journal:  Stereotact Funct Neurosurg       Date:  1991       Impact factor: 1.875

5.  Local setup errors in image-guided radiotherapy for head and neck cancer patients immobilized with a custom-made device.

Authors:  Kristina Giske; Eva M Stoiber; Michael Schwarz; Armin Stoll; Marc W Muenter; Carmen Timke; Falk Roeder; Juergen Debus; Peter E Huber; Christian Thieke; Rolf Bendl
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-10-08       Impact factor: 7.038

6.  Intensity-modulated radiotherapy for pituitary adenomas: the preliminary report of the Cleveland Clinic experience.

Authors:  Heath B Mackley; Chandana A Reddy; Shih-Yuan Lee; Gayle A Harnisch; Marc R Mayberg; Amir H Hamrahian; John H Suh
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-11-02       Impact factor: 7.038

Review 7.  [Benefit of intensity modulated and image-guided radiotherapy in prostate cancer].

Authors:  I Latorzeff; J Mazurier; C Boutry; P Dudouet; P Richaud; R de Crevoisier
Journal:  Cancer Radiother       Date:  2010-08-24       Impact factor: 1.018

8.  Comparison of geometric uncertainties using electronic portal imaging device in focal three-dimensional conformal radiation therapy using different head supports.

Authors:  Ashwini Budrukkar; Debnarayan Dutta; Dayanand Sharma; Premnath Yadav; Smitha Dantas; Rakesh Jalali
Journal:  J Cancer Res Ther       Date:  2008 Apr-Jun       Impact factor: 1.805

9.  A comprehensive assessment by tumor site of patient setup using daily MVCT imaging from more than 3,800 helical tomotherapy treatments.

Authors:  Leah K Schubert; David C Westerly; Wolfgang A Tomé; Minesh P Mehta; Emilie T Soisson; Thomas R Mackie; Mark A Ritter; Deepak Khuntia; Paul M Harari; Bhudatt R Paliwal
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-03-15       Impact factor: 7.038

10.  Evaluation of the setup accuracy of a stereotactic radiotherapy head immobilization mask system using kV on-board imaging.

Authors:  Imad Ali; Jesse Tubbs; Kerry Hibbitts; Ozer Algan; Spencer Thompson; Terence Herman; Salahuddin Ahmad
Journal:  J Appl Clin Med Phys       Date:  2010-05-20       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.