A model for susceptibility artefacts from respiration in functional echo-planar magnetic resonance imaging.

D Raj1, D P Paley, A W Anderson, R P Kennan, J C Gore.   

Abstract

Respiration causes variations in the signals acquired during magnetic resonance imaging (MRI) and therefore is a significant source of noise in functional brain imaging. A primary component of respiratory noise may arise from variations of bulk susceptibility or air volume in the chest. Here we investigate the nature of the image artefacts that can be caused by such changes. We develop a simple model which attempts to mimic the effects of variations in susceptibility and volume during respiration. Theoretical calculations, computer simulations and imaging experiments with this model show that small variations in susceptibility within the thorax from alterations in the paramagnetism of cavity gas may lead to a shift of the image on the order of 0.1 pixels as well as a shading of the intensity by +/-1%. These effects are observed to be predominant in the phase-encoding direction. They may lead to the production of spurious activations in functional MRI and are likely to be of more importance at higher field strengths.

Mesh:

Year:  2000        PMID: 11131201     DOI: 10.1088/0031-9155/45/12/321

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  23 in total

1.  Respiration artifact correction in three-dimensional proton resonance frequency MR thermometry using phase navigators.

Authors:  Bryant T Svedin; Allison Payne; Dennis L Parker
Journal:  Magn Reson Med       Date:  2015-08-13       Impact factor: 4.668

Review 2.  The contribution of neuroimaging to the study of language and aphasia.

Authors:  Andrew Lee; Vijay Kannan; Argye E Hillis
Journal:  Neuropsychol Rev       Date:  2006-12       Impact factor: 7.444

3.  Hybrid two-dimensional navigator correction: a new technique to suppress respiratory-induced physiological noise in multi-shot echo-planar functional MRI.

Authors:  Robert L Barry; L Martyn Klassen; Joy M Williams; Ravi S Menon
Journal:  Neuroimage       Date:  2007-10-11       Impact factor: 6.556

4.  Effects of air susceptibility on proton resonance frequency MR thermometry.

Authors:  Markus N Streicher; Andreas Schäfer; Enrico Reimer; Bibek Dhital; Robert Trampel; Dimo Ivanov; Robert Turner
Journal:  MAGMA       Date:  2011-04-10       Impact factor: 2.310

5.  Correction of breathing-induced errors in magnetic resonance thermometry of hyperthermia using multiecho field fitting techniques.

Authors:  Cory R Wyatt; Brian J Soher; James R MacFall
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

6.  Physiological noise in human cerebellar fMRI.

Authors:  Wietske van der Zwaag; João Jorge; Denis Butticaz; Rolf Gruetter
Journal:  MAGMA       Date:  2015-04-18       Impact factor: 2.310

7.  Functional magnetic resonance imaging of awake monkeys: some approaches for improving imaging quality.

Authors:  Gang Chen; Feng Wang; Barbara C Dillenburger; Robert M Friedman; Li M Chen; John C Gore; Malcolm J Avison; Anna W Roe
Journal:  Magn Reson Imaging       Date:  2011-11-03       Impact factor: 2.546

8.  Data-driven optimization and evaluation of 2D EPI and 3D PRESTO for BOLD fMRI at 7 Tesla: I. Focal coverage.

Authors:  Robert L Barry; Stephen C Strother; J Christopher Gatenby; John C Gore
Journal:  Neuroimage       Date:  2011-01-11       Impact factor: 6.556

9.  On the role of physiological fluctuations in quantitative gradient echo MRI: implications for GEPCI, QSM, and SWI.

Authors:  Jie Wen; Anne H Cross; Dmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2014-01-30       Impact factor: 4.668

10.  SimPACE: generating simulated motion corrupted BOLD data with synthetic-navigated acquisition for the development and evaluation of SLOMOCO: a new, highly effective slicewise motion correction.

Authors:  Erik B Beall; Mark J Lowe
Journal:  Neuroimage       Date:  2014-06-24       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.