Correction of breathing-induced errors in magnetic resonance thermometry of hyperthermia using multiecho field fitting techniques.

Cory R Wyatt1, Brian J Soher, James R MacFall.   

Abstract

PURPOSE: Breathing motion can create large errors when performing magnetic resonance (MR) thermometry of the breast. Breath holds can be used to minimize these errors, but not eliminate them. Between breath holds, the referenceless method can be used to further reduce errors by relying on regions of nonheated fatty tissue surrounding the heated region. When the surrounding tissue is heated (i.e., for a hyperthermia treatment), errors can result due to phase changes of the small amounts of water in the tissue. Therefore, an extension of the referenceless method is proposed which fits for the field in fatty tissue independent of temperature change and extrapolates it to the water-rich regions.
METHODS: Nonheating experiments were performed with male volunteers performing breath holds on top of a phantom mimicking a breast with a tumor. Heating experiments were also conducted with the same phantom while mechanically simulated breath holds were performed. A nonheating experiment was also performed with a healthy female breast. For each experiment, a nonlinear fitting algorithm was used to fit for temperature change and B0 field inside of the fatty tissue. The field changes were then extrapolated into water-rich (tumor) portions of the image using a least-squares fit to a fifth-order equation, to correct for field changes due to breath hold changes. Similar results were calculated using the image phase, to mimic the use of the referenceless method.
RESULTS: Phantom results showed large reduction of mean error and standard deviation. In the non-heating experiments, the traditional referenceless method and our extended method both corrected by similar amounts. However, in the heating experiments, the average deviation of the temperature calculated with the extended method from a fiber optic probe temperature was approximately 50% less than the deviation with the referenceless method. The in vivo breast results demonstrated reduced standard deviation and mean.
CONCLUSIONS: In this paper, we have developed an extension of the referenceless method to correct for breathing errors using multiecho fitting methods to fit for the B0 field in the fatty tissue and using measured field changes as references to extrapolate field corrections into a water-only (tumor) region. This technique has been validated in a number of situations, and in all cases, the correction method has been shown to greatly reduce temperature error in water-rich regions. The method has also been shown to be an improvement over similar methods that use image phase changes instead of field changes, particularly when temperature changes are induced.

Entities:  

Mesh:

Year:  2010        PMID: 21302786      PMCID: PMC3000859          DOI: 10.1118/1.3515462

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  35 in total

1.  Heat-source orientation and geometry dependence in proton-resonance frequency shift magnetic resonance thermometry.

Authors:  R D Peters; R S Hinks; R M Henkelman
Journal:  Magn Reson Med       Date:  1999-05       Impact factor: 4.668

2.  Analysis of thermal parameters obtained during phase III trials of hyperthermia as an adjunct to radiotherapy in the treatment of breast carcinoma.

Authors:  J W Hand; D Machin; C C Vernon; J B Whaley
Journal:  Int J Hyperthermia       Date:  1997 Jul-Aug       Impact factor: 3.914

3.  Temperature mapping using the water proton chemical shift: a chemical shift selective phase mapping method.

Authors:  K Kuroda; K Oshio; A H Chung; K Hynynen; F A Jolesz
Journal:  Magn Reson Med       Date:  1997-11       Impact factor: 4.668

4.  1H MRI phase thermometry in vivo in canine brain, muscle, and tumor tissue.

Authors:  J R MacFall; D M Prescott; H C Charles; T V Samulski
Journal:  Med Phys       Date:  1996-10       Impact factor: 4.071

5.  Relationship between thermal dose and outcome in thermoradiotherapy treatments for superficial recurrences of breast cancer: data from a phase III trial.

Authors:  M Sherar; F F Liu; M Pintilie; W Levin; J Hunt; R Hill; J Hand; C Vernon; G van Rhoon; J van der Zee; D G Gonzalez; J van Dijk; J Whaley; D Machin
Journal:  Int J Radiat Oncol Biol Phys       Date:  1997-09-01       Impact factor: 7.038

6.  Retrospective estimation and correction of physiological fluctuation in functional MRI.

Authors:  X Hu; T H Le; T Parrish; P Erhard
Journal:  Magn Reson Med       Date:  1995-08       Impact factor: 4.668

7.  Verification of a hyperthermia model method using MR thermometry.

Authors:  S T Clegg; S K Das; Y Zhang; J Macfall; E Fullar; T V Samulski
Journal:  Int J Hyperthermia       Date:  1995 May-Jun       Impact factor: 3.914

8.  A precise and fast temperature mapping using water proton chemical shift.

Authors:  Y Ishihara; A Calderon; H Watanabe; K Okamoto; Y Suzuki; K Kuroda; Y Suzuki
Journal:  Magn Reson Med       Date:  1995-12       Impact factor: 4.668

9.  Application of new technology in clinical hyperthermia.

Authors:  T V Samulski; S T Clegg; S Das; J MacFall; D M Prescott
Journal:  Int J Hyperthermia       Date:  1994 May-Jun       Impact factor: 3.914

10.  Magnetic resonance thermometry during hyperthermia for human high-grade sarcoma.

Authors:  D L Carter; J R MacFall; S T Clegg; X Wan; D M Prescott; H C Charles; T V Samulski
Journal:  Int J Radiat Oncol Biol Phys       Date:  1998-03-01       Impact factor: 7.038

View more
  10 in total

1.  Towards fast and accurate temperature mapping with proton resonance frequency-based MR thermometry.

Authors:  Jing Yuan; Chang-Sheng Mei; Lawrence P Panych; Nathan J McDannold; Bruno Madore
Journal:  Quant Imaging Med Surg       Date:  2012

2.  Multi-echo MR thermometry using iterative separation of baseline water and fat images.

Authors:  Megan E Poorman; Ieva Braškutė; Lambertus W Bartels; William A Grissom
Journal:  Magn Reson Med       Date:  2018-11-05       Impact factor: 4.668

3.  Respiration artifact correction in three-dimensional proton resonance frequency MR thermometry using phase navigators.

Authors:  Bryant T Svedin; Allison Payne; Dennis L Parker
Journal:  Magn Reson Med       Date:  2015-08-13       Impact factor: 4.668

4.  Breath-hold MR-HIFU hyperthermia: phantom and in vivo feasibility.

Authors:  Chenchen Bing; Bingbing Cheng; Robert M Staruch; Joris Nofiele; Michelle Wodzak Staruch; Debra Szczepanski; Alan Farrow-Gillespie; Adeline Yang; Theodore W Laetsch; Rajiv Chopra
Journal:  Int J Hyperthermia       Date:  2019       Impact factor: 3.914

5.  Comprehensive analysis of the Cramer-Rao bounds for magnetic resonance temperature change measurement in fat-water voxels using multi-echo imaging.

Authors:  Cory Wyatt; Brian J Soher; Kavitha Arunachalam; James MacFall
Journal:  MAGMA       Date:  2011-03-27       Impact factor: 2.310

6.  Pediatric Sarcomas Are Targetable by MR-Guided High Intensity Focused Ultrasound (MR-HIFU): Anatomical Distribution and Radiological Characteristics.

Authors:  Jenny Shim; Robert M Staruch; Korgun Koral; Xian-Jin Xie; Rajiv Chopra; Theodore W Laetsch
Journal:  Pediatr Blood Cancer       Date:  2016-05-19       Impact factor: 3.167

7.  Drift correction for accurate PRF-shift MR thermometry during mild hyperthermia treatments with MR-HIFU.

Authors:  Chenchen Bing; Robert M Staruch; Matti Tillander; Max O Köhler; Charles Mougenot; Mika Ylihautala; Theodore W Laetsch; Rajiv Chopra
Journal:  Int J Hyperthermia       Date:  2016-05-22       Impact factor: 3.914

8.  Quality of MR thermometry during palliative MR-guided high-intensity focused ultrasound (MR-HIFU) treatment of bone metastases.

Authors:  Mie K Lam; Merel Huisman; Robbert J Nijenhuis; Maurice Aaj van den Bosch; Max A Viergever; Chrit Tw Moonen; Lambertus W Bartels
Journal:  J Ther Ultrasound       Date:  2015-03-24

9.  Anatomical Phase Extraction (APE) Method: A Novel Method to Correct Detrimental Effects of Tissue-Inhomogeneity in Referenceless MR Thermometry-Preliminary Ex Vivo Investigation.

Authors:  Chien-Feng Judith Huang; Win-Li Lin; San-Chao Hwang; Ching Yao; Hsu Chang; Li-Wei Kuo
Journal:  Comput Math Methods Med       Date:  2021-08-10       Impact factor: 2.238

10.  Heat Modulation of Intrinsic MR Contrasts for Tumor Characterization.

Authors:  Matthew Tarasek; Oguz Akin; Jeannette Roberts; Thomas Foo; Desmond Yeo
Journal:  Cancers (Basel)       Date:  2022-01-14       Impact factor: 6.639

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.