Literature DB >> 21232613

Data-driven optimization and evaluation of 2D EPI and 3D PRESTO for BOLD fMRI at 7 Tesla: I. Focal coverage.

Robert L Barry1, Stephen C Strother, J Christopher Gatenby, John C Gore.   

Abstract

Blood oxygenation level dependent (BOLD) functional magnetic resonance imaging (fMRI) is commonly performed using 2D single-shot echo-planar imaging (EPI). However, single-shot EPI at 7 Tesla (T) often suffers from significant geometric distortions (due to low bandwidth (BW) in the phase-encode (PE) direction) and amplified physiological noise. Recent studies have suggested that 3D multi-shot sequences such as PRESTO may offer comparable BOLD contrast-to-noise ratio with increased volume coverage and decreased geometric distortions. Thus, a four-way group-level comparison was performed between 2D and 3D acquisition sequences at two in-plane resolutions. The quality of fMRI data was evaluated via metrics of prediction and reproducibility using NPAIRS (Non-parametric Prediction, Activation, Influence and Reproducibility re-Sampling). Group activation maps were optimized for each acquisition strategy by selecting the number of principal components that jointly maximized prediction and reproducibility, and showed good agreement in sensitivity and specificity for positive BOLD changes. High-resolution EPI exhibited the highest z-scores of the four acquisition sequences; however, it suffered from the lowest BW in the PE direction (resulting in the worst geometric distortions) and limited spatial coverage, and also caused some subject discomfort through peripheral nerve stimulation (PNS). In comparison, PRESTO also had high z-scores (higher than EPI for a matched in-plane resolution), the highest BW in the PE direction (producing images with superior geometric fidelity), the potential for whole-brain coverage, and no reported PNS. This study provides evidence to support the use of 3D multi-shot acquisition sequences in lieu of single-shot EPI for ultra high field BOLD fMRI at 7T.
Copyright © 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21232613      PMCID: PMC3049844          DOI: 10.1016/j.neuroimage.2010.12.086

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  59 in total

1.  The evaluation of preprocessing choices in single-subject BOLD fMRI using NPAIRS performance metrics.

Authors:  Stephen LaConte; Jon Anderson; Suraj Muley; James Ashe; Sally Frutiger; Kelly Rehm; Lars Kai Hansen; Essa Yacoub; Xiaoping Hu; David Rottenberg; Stephen Strother
Journal:  Neuroimage       Date:  2003-01       Impact factor: 6.556

2.  FLASH imaging: rapid NMR imaging using low flip-angle pulses. 1986.

Authors:  A Haase; J Frahm; D Matthaei; W Hänicke; K-D Merboldt
Journal:  J Magn Reson       Date:  2011-12       Impact factor: 2.229

3.  Enhanced sensitivity with fast three-dimensional blood-oxygen-level-dependent functional MRI: comparison of SENSE-PRESTO and 2D-EPI at 3 T.

Authors:  Sebastiaan F W Neggers; Erno J Hermans; Nick F Ramsey
Journal:  NMR Biomed       Date:  2008-08       Impact factor: 4.044

4.  Three dimensional echo-planar imaging at 7 Tesla.

Authors:  B A Poser; P J Koopmans; T Witzel; L L Wald; M Barth
Journal:  Neuroimage       Date:  2010-02-06       Impact factor: 6.556

5.  Sensory stimulation by time-varying magnetic fields.

Authors:  M S Cohen; R M Weisskoff; R R Rzedzian; H L Kantor
Journal:  Magn Reson Med       Date:  1990-05       Impact factor: 4.668

6.  Tesla gradient recalled echo characteristics of photic stimulation-induced signal changes in the human primary visual cortex.

Authors:  R S Menon; S Ogawa; D W Tank; K Uğurbil
Journal:  Magn Reson Med       Date:  1993-09       Impact factor: 4.668

7.  Echo-planar imaging of the brain at 3.0 T: first normal volunteer results.

Authors:  P Mansfield; R Coxon; P Glover
Journal:  J Comput Assist Tomogr       Date:  1994 May-Jun       Impact factor: 1.826

8.  A functional MRI technique combining principles of echo-shifting with a train of observations (PRESTO).

Authors:  G Liu; G Sobering; J Duyn; C T Moonen
Journal:  Magn Reson Med       Date:  1993-12       Impact factor: 4.668

9.  Very fast MR imaging by field echoes and small angle excitation.

Authors:  P van der Meulen; J P Groen; J J Cuppen
Journal:  Magn Reson Imaging       Date:  1985       Impact factor: 2.546

10.  Water proton T1 measurements in brain tissue at 7, 3, and 1.5 T using IR-EPI, IR-TSE, and MPRAGE: results and optimization.

Authors:  P J Wright; O E Mougin; J J Totman; A M Peters; M J Brookes; R Coxon; P E Morris; M Clemence; S T Francis; R W Bowtell; P A Gowland
Journal:  MAGMA       Date:  2008-02-08       Impact factor: 2.310

View more
  18 in total

1.  Breakdown of the brain's functional network modularity with awareness.

Authors:  Douglass Godwin; Robert L Barry; René Marois
Journal:  Proc Natl Acad Sci U S A       Date:  2015-03-10       Impact factor: 11.205

2.  Comparing functional MRI protocols for small, iron-rich basal ganglia nuclei such as the subthalamic nucleus at 7 T and 3 T.

Authors:  Gilles de Hollander; Max C Keuken; Wietske van der Zwaag; Birte U Forstmann; Robert Trampel
Journal:  Hum Brain Mapp       Date:  2017-03-27       Impact factor: 5.038

3.  Reproducibility of resting state spinal cord networks in healthy volunteers at 7 Tesla.

Authors:  Robert L Barry; Baxter P Rogers; Benjamin N Conrad; Seth A Smith; John C Gore
Journal:  Neuroimage       Date:  2016-02-26       Impact factor: 6.556

4.  Human neuroimaging as a "Big Data" science.

Authors:  John Darrell Van Horn; Arthur W Toga
Journal:  Brain Imaging Behav       Date:  2014-06       Impact factor: 3.978

Review 5.  The PRESTO technique for fMRI.

Authors:  P van Gelderen; J H Duyn; N F Ramsey; G Liu; C T W Moonen
Journal:  Neuroimage       Date:  2012-01-08       Impact factor: 6.556

6.  Enhanced phase regression with Savitzky-Golay filtering for high-resolution BOLD fMRI.

Authors:  Robert L Barry; John C Gore
Journal:  Hum Brain Mapp       Date:  2014-01-17       Impact factor: 5.038

7.  Improving measurement of functional connectivity through decreasing partial volume effects at 7 T.

Authors:  Allen T Newton; Baxter P Rogers; John C Gore; Victoria L Morgan
Journal:  Neuroimage       Date:  2011-09-08       Impact factor: 6.556

8.  Complex and magnitude-only preprocessing of 2D and 3D BOLD fMRI data at 7 T.

Authors:  Robert L Barry; Stephen C Strother; John C Gore
Journal:  Magn Reson Med       Date:  2011-07-11       Impact factor: 4.668

9.  A study-specific fMRI normalization approach that operates directly on high resolution functional EPI data at 7 Tesla.

Authors:  Günther Grabner; Benedikt A Poser; Kyoko Fujimoto; Jonathan R Polimeni; Lawrence L Wald; Siegfried Trattnig; Ivan Toni; Markus Barth
Journal:  Neuroimage       Date:  2014-06-25       Impact factor: 6.556

10.  Multiple sclerosis lesions affect intrinsic functional connectivity of the spinal cord.

Authors:  Benjamin N Conrad; Robert L Barry; Baxter P Rogers; Satoshi Maki; Arabinda Mishra; Saakshi Thukral; Subramaniam Sriram; Aashim Bhatia; Siddharama Pawate; John C Gore; Seth A Smith
Journal:  Brain       Date:  2018-06-01       Impact factor: 13.501

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.