Abstract

An examination is made of dipole location errors in electroencephalogram (EEG) source analysis, due to not incorporating the ventricular system (VS), omitting a hole in the skull and underestimating skull conductivity. The simulations are performed for a large number of test dipoles in 3D using the finite difference method. The maximum dipole location error encountered, utilising 27 and 53 electrodes is 7.6 mm and 6.1 mm, respectively when omitting the VS, 5.6 mm and 5.2 mm, respectively when neglecting the hole in the skull, and 33.4 mm and 28.0 mm, respectively when underestimating skull conductivity. The largest location errors due to neglecting the VS can be found in the vicinity of the VS. The largest location errors due to omitting a hole can be found in the vicinity of the hole. At these positions the fitted dipoles are found close to the hole. When skull conductivity is underestimated, the dipole is fitted close to the skull-brain border in a radial direction for all test dipoles. It was found that the location errors due to underestimating skull conductivity are typically higher than those found due to neglecting the VS or neglecting a hole in the skull.

Mesh:

Year:  2000        PMID: 11094809     DOI: 10.1007/BF02345748

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  19 in total

1.  An improved method for localizing electric brain dipoles.

Authors:  Y Salu; L G Cohen; D Rose; S Sato; C Kufta; M Hallett
Journal:  IEEE Trans Biomed Eng       Date:  1990-07       Impact factor: 4.538

2.  Dipole modeling in epilepsy surgery candidates.

Authors:  P Boon; M D'Havé; C Adam; K Vonck; M Baulac; T Vandekerckhove; J De Reuck
Journal:  Epilepsia       Date:  1997-02       Impact factor: 5.864

3.  How well does a three-sphere model predict positions of dipoles in a realistically shaped head?

Authors:  B J Roth; M Balish; A Gorbach; S Sato
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1993-10

4.  Volume conduction effects in EEG and MEG.

Authors:  S P van den Broek; F Reinders; M Donderwinkel; M J Peters
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1998-06

5.  Multimodal image coregistration and partitioning--a unified framework.

Authors:  J Ashburner; K Friston
Journal:  Neuroimage       Date:  1997-10       Impact factor: 6.556

6.  A systematic evaluation of the spherical model accuracy in EEG dipole localization.

Authors:  B Yvert; O Bertrand; M Thévenet; J F Echallier; J Pernier
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1997-05

7.  EEG electrode sensitivity--an application of reciprocity.

Authors:  S Rush; D A Driscoll
Journal:  IEEE Trans Biomed Eng       Date:  1969-01       Impact factor: 4.538

8.  The electrical conductivity of human cerebrospinal fluid at body temperature.

Authors:  S B Baumann; D R Wozny; S K Kelly; F M Meno
Journal:  IEEE Trans Biomed Eng       Date:  1997-03       Impact factor: 4.538

9.  Validation of a detailed computer model for the electric fields in the brain.

Authors:  P Laarne; H Eskola; J Hyttinen; V Suihko; J Malmivuo
Journal:  J Med Eng Technol       Date:  1995 Mar-Jun

10.  Effects of local variations in skull and scalp thickness on EEG's and MEG's.

Authors:  B N Cuffin
Journal:  IEEE Trans Biomed Eng       Date:  1993-01       Impact factor: 4.538

View more
  13 in total

1.  Finite difference iterative solvers for electroencephalography: serial and parallel performance analysis.

Authors:  Derek N Barnes; John S George; Kwong T Ng
Journal:  Med Biol Eng Comput       Date:  2008-05-14       Impact factor: 2.602

2.  Relationship of EEG sources of neonatal seizures to acute perinatal brain lesions seen on MRI: a pilot study.

Authors:  Ivana Despotovic; Perumpillichira J Cherian; Maarten De Vos; Hans Hallez; Wouter Deburchgraeve; Paul Govaert; Maarten Lequin; Gerhard H Visser; Renate M Swarte; Ewout Vansteenkiste; Sabine Van Huffel; Wilfried Philips
Journal:  Hum Brain Mapp       Date:  2012-04-21       Impact factor: 5.038

3.  Effects of skull thickness, anisotropy, and inhomogeneity on forward EEG/ERP computations using a spherical three-dimensional resistor mesh model.

Authors:  Nicolas Chauveau; Xavier Franceries; Bernard Doyon; Bernard Rigaud; Jean Pierre Morucci; Pierre Celsis
Journal:  Hum Brain Mapp       Date:  2004-02       Impact factor: 5.038

4.  Simultaneous head tissue conductivity and EEG source location estimation.

Authors:  Zeynep Akalin Acar; Can E Acar; Scott Makeig
Journal:  Neuroimage       Date:  2015-08-22       Impact factor: 6.556

Review 5.  EEG source imaging in epilepsy--practicalities and pitfalls.

Authors:  Kitti Kaiboriboon; Hans O Lüders; Mehdi Hamaneh; John Turnbull; Samden D Lhatoo
Journal:  Nat Rev Neurol       Date:  2012-08-07       Impact factor: 42.937

6.  Validating the boundary element method for forward and inverse EEG computations in the presence of a hole in the skull.

Authors:  Robert Oostenveld; Thom F Oostendorp
Journal:  Hum Brain Mapp       Date:  2002-11       Impact factor: 5.038

Review 7.  Review on solving the forward problem in EEG source analysis.

Authors:  Hans Hallez; Bart Vanrumste; Roberta Grech; Joseph Muscat; Wim De Clercq; Anneleen Vergult; Yves D'Asseler; Kenneth P Camilleri; Simon G Fabri; Sabine Van Huffel; Ignace Lemahieu
Journal:  J Neuroeng Rehabil       Date:  2007-11-30       Impact factor: 4.262

8.  EEG/MEG source imaging: methods, challenges, and open issues.

Authors:  Katrina Wendel; Outi Väisänen; Jaakko Malmivuo; Nevzat G Gencer; Bart Vanrumste; Piotr Durka; Ratko Magjarević; Selma Supek; Mihail Lucian Pascu; Hugues Fontenelle; Rolando Grave de Peralta Menendez
Journal:  Comput Intell Neurosci       Date:  2009-07-20

9.  Effects of forward model errors on EEG source localization.

Authors:  Zeynep Akalin Acar; Scott Makeig
Journal:  Brain Topogr       Date:  2013-01-26       Impact factor: 3.020

10.  Dense array EEG source estimation in neocortical epilepsy.

Authors:  Madoka Yamazaki; Don M Tucker; Marie Terrill; Ayataka Fujimoto; Takamichi Yamamoto
Journal:  Front Neurol       Date:  2013-05-13       Impact factor: 4.003

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.