Literature DB >> 11061454

Lavage technique in total hip arthroplasty: jet lavage produces better cement penetration than syringe lavage in the proximal femur.

S J Breusch1, T L Norman, U Schneider, T Reitzel, J D Blaha, M Lukoschek.   

Abstract

Sixteen paired human cadaver femora were prepared using conventional broaches. Cancellous bone was irrigated with 1 L pulsed lavage in one femur and 1 L syringe lavage in the contralateral femur. The specimens were embedded in specially designed pots, and vacuum-mixed bone-cements were applied in a retrograde manner. After application of a standard pressure to the pots, the femora were removed and radiographed, and horizontal sections were obtained and analyzed to assess cement penetration into cancellous bone and the ratio of the area of supported to unsupported cancellous bone (Rcb). Our results show that in equal quality bone, the use of jet lavage yields significantly (P < .0001) improved cement penetration and Rcb compared with syringe lavage specimens. Jet lavage should be considered routine to achieve interdigitation with cancellous bone in cemented total hip arthroplasty.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11061454     DOI: 10.1054/arth.2000.8098

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  11 in total

1.  Pulsed lavage improves fixation strength of cemented tibial components.

Authors:  Ulf J Schlegel; Jan Siewe; Karl S Delank; Peer Eysel; Klaus Püschel; Michael M Morlock; Anne Gebert de Uhlenbrock
Journal:  Int Orthop       Date:  2010-10-16       Impact factor: 3.075

Review 2.  Bone cement.

Authors:  Raju Vaishya; Mayank Chauhan; Abhishek Vaish
Journal:  J Clin Orthop Trauma       Date:  2013-12-15

3.  [The influence of jet-lavage systems on in vitro cement penetration].

Authors:  C-R Becker; B Lehner; S Ungethüm; S J Breusch
Journal:  Orthopade       Date:  2006-05       Impact factor: 1.087

4.  Pulsed lavage reduces the incidence of radiolucent lines under the tibial tray of Oxford unicompartmental knee arthroplasty: pulsed lavage versus syringe lavage.

Authors:  Michael Clarius; Christian Hauck; Joern B Seeger; Andrew James; David W Murray; Peter R Aldinger
Journal:  Int Orthop       Date:  2009-02-14       Impact factor: 3.075

Review 5.  [Cementing techniques for hip resurfacing arthroplasty. What do we know?].

Authors:  R G Bitsch; T P Schmalzried
Journal:  Orthopade       Date:  2008-07       Impact factor: 1.087

6.  Short-keeled cemented tibial components show an increased risk for aseptic loosening.

Authors:  Christian Ries; Markus Heinichen; Florian Dietrich; Eike Jakubowitz; Christian Sobau; Christian Heisel
Journal:  Clin Orthop Relat Res       Date:  2012-10-05       Impact factor: 4.176

7.  Comparison of different cement application techniques for tibial component fixation in TKA.

Authors:  Ulf J Schlegel; Nicholas E Bishop; Klaus Püschel; Michael M Morlock; Katrin Nagel
Journal:  Int Orthop       Date:  2014-08-01       Impact factor: 3.075

8.  Secondary cement injection technique reduces pulmonary embolism in total hip arthroplasty.

Authors:  Florian Schmidutz; Tobias Düll; Ole Voges; Thomas Grupp; Peter Müller; Volkmar Jansson
Journal:  Int Orthop       Date:  2012-04-15       Impact factor: 3.075

9.  Basic science considerations in primary total hip replacement arthroplasty.

Authors:  Saqeb B Mirza; Douglas G Dunlop; Sukhmeet S Panesar; Syed G Naqvi; Shafat Gangoo; Saif Salih
Journal:  Open Orthop J       Date:  2010-05-11

10.  Tibial cleaning method for cemented total knee arthroplasty: An experimental study.

Authors:  Peter Helwig; Lukas Konstantinidis; Anja Hirschmüller; Verena Miltenberger; Kerstin Kuminack; Norbert P Südkamp; Oliver Hauschild
Journal:  Indian J Orthop       Date:  2013-01       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.