CT-SPECT fusion plus conjugate views for determining dosimetry in iodine-131-monoclonal antibody therapy of lymphoma patients.

K F Koral1, K R Zasadny, M L Kessler, J Q Luo, S F Buchbinder, M S Kaminski, I Francis, R L Wahl.   

Abstract

UNLABELLED: A method for performing 131I quantitative SPECT imaging is described which uses the superimposition of markers placed on the skin to accomplish fusion of computed tomography (CT) and SPECT image sets.
METHODS: To calculate mean absorbed dose after administration of one of two 131I-labeled monoclonal antibodies (Mabs), the shape of the time-activity curve is measured by daily diagnostic conjugate views, the y-axis of that curve is normalized by a quantitative SPECT measurement (usually intra-therapy), and the tumor mass is deduced from a concurrent CT volume measurement. The method is applied to six B-cell non-Hodgkin's lymphoma patients.
RESULTS: For four tumors in three patients treated with the MB1 Mab, a correlation appears to be present between resulting mean absorbed dose and disease response. Including all dosimetric estimates for both antibodies, the range for the specific absorbed dose is within that found by others in treating B-cell lymphoma patients. Excluding a retreated anti-B1 patient, the tumor-specific absorbed dose during anti-B1 therapy is from 1.4 to 1.7 mGy/MBq. For the one anti-B1 patient, where quantitative SPECT and conjugate-view imaging was carried out back to back, the quantitative SPECT-measured activity was somewhat less for the spleen and much less for the tumor than that from conjugate views.
CONCLUSION: The quantitative SPECT plus conjugate views method may be of general utility for macro-dosimetry of 131I therapies.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7931676

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  16 in total

1.  Characterization of scatter and penetration using Monte Carlo simulation in 131I imaging.

Authors:  Y K Dewaraja; M Ljungberg; K F Koral
Journal:  J Nucl Med       Date:  2000-01       Impact factor: 10.057

Review 2.  Fluorine-18-deoxyglucose SPECT and coincidence imaging for myocardial viability: Clinical and technologic issues.

Authors:  V Dilsizian; S L Bacharach; M M Khin; M F Smith
Journal:  J Nucl Cardiol       Date:  2001 Jan-Feb       Impact factor: 5.952

3.  Effects of shortened acquisition time on accuracy and precision of quantitative estimates of organ activity.

Authors:  Bin He; Eric C Frey
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

4.  EQPlanar: a maximum-likelihood method for accurate organ activity estimation from whole body planar projections.

Authors:  N Song; B He; R L Wahl; E C Frey
Journal:  Phys Med Biol       Date:  2011-08-03       Impact factor: 3.609

5.  Comparison of residence time estimation methods for radioimmunotherapy dosimetry and treatment planning--Monte Carlo simulation studies.

Authors:  B He; R L Wahl; Y Du; G Sgouros; H Jacene; I Flinn; E C Frey
Journal:  IEEE Trans Med Imaging       Date:  2008-04       Impact factor: 10.048

Review 6.  Technological development and advances in single-photon emission computed tomography/computed tomography.

Authors:  Youngho Seo; Carina Mari; Bruce H Hasegawa
Journal:  Semin Nucl Med       Date:  2008-05       Impact factor: 4.446

7.  Activity quantification combining conjugate-view planar scintigraphies and SPECT/CT data for patient-specific 3-D dosimetry in radionuclide therapy.

Authors:  Yannick Berker; Andreas Goedicke; Gerrit J Kemerink; Til Aach; Bernd Schweizer
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-09-08       Impact factor: 9.236

8.  Abdominal SPECT/MRI fusion applied to the study of splenic and hepatic uptake of radiolabeled thrombocytes and colloids.

Authors:  H K Pohjonen; S E Savolainen; P H Nikkinen; V P Poutanen; E T Korppi-Tommola; B K Liewendahl
Journal:  Ann Nucl Med       Date:  1996-11       Impact factor: 2.668

Review 9.  Accuracy and precision of radioactivity quantification in nuclear medicine images.

Authors:  Eric C Frey; John L Humm; Michael Ljungberg
Journal:  Semin Nucl Med       Date:  2012-05       Impact factor: 4.446

10.  Evaluation of quantitative imaging methods for organ activity and residence time estimation using a population of phantoms having realistic variations in anatomy and uptake.

Authors:  Bin He; Yong Du; W Paul Segars; Richard L Wahl; George Sgouros; Heather Jacene; Eric C Frey
Journal:  Med Phys       Date:  2009-02       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.