Monte Carlo verification of IMRT dose distributions from a commercial treatment planning optimization system.

C M Ma1, T Pawlicki, S B Jiang, J S Li, J Deng, E Mok, A Kapur, L Xing, L Ma, A L Boyer.   

Abstract

The purpose of this work was to use Monte Carlo simulations to verify the accuracy of the dose distributions from a commercial treatment planning optimization system (Corvus, Nomos Corp., Sewickley, PA) for intensity-modulated radiotherapy (IMRT). A Monte Carlo treatment planning system has been implemented clinically to improve and verify the accuracy of radiotherapy dose calculations. Further modifications to the system were made to compute the dose in a patient for multiple fixed-gantry IMRT fields. The dose distributions in the experimental phantoms and in the patients were calculated and used to verify the optimized treatment plans generated by the Corvus system. The Monte Carlo calculated IMRT dose distributions agreed with the measurements to within 2% of the maximum dose for all the beam energies and field sizes for both the homogeneous and heterogeneous phantoms. The dose distributions predicted by the Corvus system, which employs a finite-size pencil beam (FSPB) algorithm, agreed with the Monte Carlo simulations and measurements to within 4% in a cylindrical water phantom with various hypothetical target shapes. Discrepancies of more than 5% (relative to the prescribed target dose) in the target region and over 20% in the critical structures were found in some IMRT patient calculations. The FSPB algorithm as implemented in the Corvus system is adequate for homogeneous phantoms (such as prostate) but may result in significant under or over-estimation of the dose in some cases involving heterogeneities such as the air-tissue, lung-tissue and tissue-bone interfaces.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11008950     DOI: 10.1088/0031-9155/45/9/303

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  28 in total

1.  [Intensity modulated radiotherapy (IMRT) of head and neck tumors. Increased biological effectiveness in high-risk situations by "integrated boost" therapy].

Authors:  D Milanovic; F Lohr; K Götte; B Dobler; B Hermann; K Hörmann; F Wenz
Journal:  HNO       Date:  2004-08       Impact factor: 1.284

2.  Dose attenuation effect of hip prostheses in a 9-MV photon beam: commercial treatment planning system versus Monte Carlo calculations.

Authors:  Asghar Mesbahi; Farshad Seyed Nejad
Journal:  Radiat Med       Date:  2007-12-25

3.  Dosimetric impact of motion in free-breathing and gated lung radiotherapy: a 4D Monte Carlo study of intrafraction and interfraction effects.

Authors:  Joao Seco; Greg C Sharp; Ziji Wu; David Gierga; Florian Buettner; Harald Paganetti
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

4.  Technical note: Heterogeneity dose calculation accuracy in IMRT: study of five commercial treatment planning systems using an anthropomorphic thorax phantom.

Authors:  Scott E Davidson; Richard A Popple; Geoffrey S Ibbott; David S Followill
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

5.  Monitor unit calculations for external photon and electron beams: Report of the AAPM Therapy Physics Committee Task Group No. 71.

Authors:  John P Gibbons; John A Antolak; David S Followill; M Saiful Huq; Eric E Klein; Kwok L Lam; Jatinder R Palta; Donald M Roback; Mark Reid; Faiz M Khan
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

6.  Commissioning of 6 MV medical linac for dynamic MLC-based IMRT on Monte Carlo code GEANT4.

Authors:  Hiroyuki Okamoto; Yukio Fujita; Kyoko Sakama; Hidetoshi Saitoh; Tatsuaki Kanai; Jun Itami; Toshiyuki Kohno
Journal:  Radiol Phys Technol       Date:  2014-02-08

7.  Concurrent Monte Carlo transport and fluence optimization with fluence adjusting scalable transport Monte Carlo.

Authors:  Y M Yang; M Svatos; C Zankowski; B Bednarz
Journal:  Med Phys       Date:  2016-06       Impact factor: 4.071

8.  EGSnrc application for IMRT planning.

Authors:  Sitti Yani; Ilmi Rizkia; Mohamad Fahdillah Rhani; Mohammad Haekal; Freddy Haryanto
Journal:  Rep Pract Oncol Radiother       Date:  2020-01-22

9.  Study of efficiency in five-field and field-by-field intensity modulated radiation therapy (IMRT) plan using DOSXYZnrc Monte Carlo code.

Authors:  Sitti Yani; Indra Budiansah; Mohamad Fahdillah Rhani; Freddy Haryanto
Journal:  Rep Pract Oncol Radiother       Date:  2020-04-27

10.  Monte Carlo dose verification of prostate patients treated with simultaneous integrated boost intensity modulated radiation therapy.

Authors:  Nesrin Dogan; Ivaylo Mihaylov; Yan Wu; Paul J Keall; Jeffrey V Siebers; Michael P Hagan
Journal:  Radiat Oncol       Date:  2009-06-15       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.