Large-sliding contact elements accurately predict levels of bone-implant micromotion relevant to osseointegration.

M Viceconti1, R Muccini, M Bernakiewicz, M Baleani, L Cristofolini.   

Abstract

Primary stability is recognised as an important determinant in the aseptic loosening failure process of cementless implants. An accurate evaluation of the bone-implant relative micromotion is becoming important both in pre-clinical and clinical studies. If the biological threshold for micro-movements is in the range 100-200 micrometer then, in order to be discriminative, any method used to evaluate the primary stability should have an accuracy of 10-20 micrometer or better. Additionally, such method should also be able to report the relative micromotion at each point of the interface. None of the available experimental methods satisfies both requirements. Aim of the present study is to verify if any of the current finite element modelling techniques is sufficiently accurate in predicting the primary stability of a cementless prosthesis to be used to decide whether the micromotion may or may not jeopardise the implant osseointegration. The primary stability of an anatomic cementless stem, as measured in vitro, was used as a benchmark problem to comparatively evaluate different contact modelling techniques. Frictionless contact, frictional contact and press-fitted frictional contact conditions were modelled using alternatively node-to-node, node-to-face and face-to-face contact elements. The model based on face-to-face contact elements accounting for frictional contact and initial press-fit was able to predict the micromotion measured experimentally with an average (RMS) error of 10 micrometer and a peak error of 14 micrometer. All the other models presented errors higher than 20 micrometer assumed in the present study as an accuracy threshold.

Entities:  

Mesh:

Year:  2000        PMID: 11006385     DOI: 10.1016/s0021-9290(00)00140-8

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  33 in total

1.  Effect of the initial implant fitting on the predicted secondary stability of a cementless stem.

Authors:  M Viceconti; A Pancanti; M Dotti; F Traina; L Cristofolini
Journal:  Med Biol Eng Comput       Date:  2004-03       Impact factor: 2.602

2.  Numerical model to predict the long-term mechanical stability of cementless orthopaedic implants.

Authors:  M Viceconti; S Ricci; A Pancanti; A Cappello
Journal:  Med Biol Eng Comput       Date:  2004-11       Impact factor: 2.602

3.  Biomechanical analysis of the tibial tray design in TKA: comparison between modular and offset tibial trays.

Authors:  Ângela Chan; João Gamelas; João Folgado; Paulo R Fernandes
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-08-28       Impact factor: 4.342

4.  Periprosthetic fractures may be more likely in cementless femoral stems with sharp edges.

Authors:  K Hu; X Zhang; J Zhu; C Wang; W Ji; X Bai
Journal:  Ir J Med Sci       Date:  2009-10-22       Impact factor: 1.568

Review 5.  New Developments of Ti-Based Alloys for Biomedical Applications.

Authors:  Yuhua Li; Chao Yang; Haidong Zhao; Shengguan Qu; Xiaoqiang Li; Yuanyuan Li
Journal:  Materials (Basel)       Date:  2014-03-04       Impact factor: 3.623

6.  Validation of FE micromotions and strains around a press-fit cup: introducing a new micromotion measuring technique.

Authors:  S G Clarke; A T M Phillips; A M J Bull
Journal:  Ann Biomed Eng       Date:  2012-02-16       Impact factor: 3.934

7.  Development of Multifunctional Commercial Pure Titanium-Polyethylene Glycol Drug-Eluting Substrates with Enhanced Optical and Antithrombotic Properties.

Authors:  Monalisha Mohanta; A Thirugnanam
Journal:  Cardiovasc Eng Technol       Date:  2022-06-14       Impact factor: 2.495

8.  The improved biological performance of a novel low elastic modulus implant.

Authors:  Lei Shi; Lei Shi; Ling Wang; Yonghong Duan; Wei Lei; Zhen Wang; Jing Li; Xiangli Fan; Xiaokang Li; Shujun Li; Zheng Guo
Journal:  PLoS One       Date:  2013-02-21       Impact factor: 3.240

9.  In vivo loading on the hip joint in patients with total hip replacement performing gymnastics and aerobics exercises.

Authors:  Henryk Haffer; Srdan Popovic; Franziska Martin; Sebastian Hardt; Tobias Winkler; Philipp Damm
Journal:  Sci Rep       Date:  2021-06-28       Impact factor: 4.379

Review 10.  Micromotions and combined damages at the dental implant/bone interface.

Authors:  Shan-Shan Gao; Ya-Rong Zhang; Zhuo-Li Zhu; Hai-Yang Yu
Journal:  Int J Oral Sci       Date:  2012-12-21       Impact factor: 6.344

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.