Literature DB >> 10992316

3D MR DSA: effects of injection protocol and image masking.

R Frayne1, T M Grist, J S Swan, D C Peters, F R Korosec, C A Mistretta.   

Abstract

The purpose of this study was to investigate the effect on three-dimensional (3D) magnetic resonance digital subtraction angiography (MR DSA) images of various injection protocol parameters (ie, injection order, volume, and rate), as well as image masking. The pelves of 10 normal volunteers were scanned using seven different contrast agent volume/injection rate combinations. Subtraction of a precontrast mask image resulted in vascular image contrast improvements of between 4.0 and 7.7 times. Image quality and smaller vessel image contrast in the masked data decreased with increasing injection number. Data acquired with a high (0.150 mmol kg(-1)) volume yielded the highest quality images, although only small nonsignificant differences in image quality and large vessel conspicuity were found between images obtained using the high and medium (0.075 mmol kg(-1)) volumes. Images acquired with a low (0. 038 mmol kg(-1)) volume, while of lower image contrast, were judged to be of reasonable quality, especially when acquired as the first or second injection. Injection rate (1 ml s(-1), 2 ml s(-1), and 4 ml s(-1)) was not found to affect the images significantly, although selection of an injection rate that gave an injection duration of approximately 10 seconds tended to give better vascular image contrast. Based on these data, a series of escalating volumes for multi-injection examination is proposed. J. Magn. Reson. Imaging 2000;12:476-487. Copyright 2000 Wiley-Liss, Inc.

Mesh:

Substances:

Year:  2000        PMID: 10992316     DOI: 10.1002/1522-2586(200009)12:3<476::aid-jmri14>3.0.co;2-f

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  9 in total

1.  Time-resolved contrast-enhanced carotid MR angiography using sensitivity encoding (SENSE).

Authors:  X Golay; S J Brown; R Itoh; E R Melhem
Journal:  AJNR Am J Neuroradiol       Date:  2001-09       Impact factor: 3.825

Review 2.  Neurovascular MRI with dynamic contrast-enhanced subtraction angiography.

Authors:  S C Coley; J M Wild; I D Wilkinson; P D Griffiths
Journal:  Neuroradiology       Date:  2003-09-20       Impact factor: 2.804

3.  Three-dimensional dynamic magnetic resonance angiography for the evaluation of radiosurgically treated cerebral arteriovenous malformations.

Authors:  Jean-Yves Gauvrit; Catherine Oppenheim; Francois Nataf; Olivier Naggara; Denis Trystram; Thierry Munier; Daniel Fredy; Jean-Pierre Pruvo; François-Xavier Roux; Xavier Leclerc; Jean-François Meder
Journal:  Eur Radiol       Date:  2005-10-12       Impact factor: 5.315

4.  The impact of the dosage of intravenous gadolinium-chelates on the vascular signal intensity in MR angiography.

Authors:  Johannes T Heverhagen; Isabelle Reitz; Martina Pavlicova; Andrea L Levine; Klaus J Klose; Hans-Joachim Wagner
Journal:  Eur Radiol       Date:  2006-09-30       Impact factor: 5.315

5.  Dose comparison of single versus double dose in contrast-enhanced magnetic resonance angiography of the renal arteries: intra-individual cross-over blinded trial using Gd-DTPA.

Authors:  J T Heverhagen; C L Wright; P Schmalbrock; M V Knopp
Journal:  Eur Radiol       Date:  2008-07-25       Impact factor: 5.315

6.  3D time-resolved MR angiography (MRA) of the carotid arteries with time-resolved imaging with stochastic trajectories: comparison with 3D contrast-enhanced Bolus-Chase MRA and 3D time-of-flight MRA.

Authors:  R P Lim; M Shapiro; E Y Wang; M Law; J S Babb; L E Rueff; J S Jacob; S Kim; R H Carson; T P Mulholland; G Laub; E M Hecht
Journal:  AJNR Am J Neuroradiol       Date:  2008-09-03       Impact factor: 3.825

7.  Three-dimensional dynamic MR digital subtraction angiography using sensitivity encoding for the evaluation of intracranial arteriovenous malformations: a preliminary study.

Authors:  Jean-Yves Gauvrit; Xavier Leclerc; Catherine Oppenheim; Thierry Munier; Denis Trystram; Henda Rachdi; François Nataf; Jean-Pierre Pruvo; Jean-François Meder
Journal:  AJNR Am J Neuroradiol       Date:  2005 Jun-Jul       Impact factor: 3.825

8.  A comparison of 4D time-resolved MRA with keyhole and 3D time-of-flight MRA at 3.0 T for the evaluation of cerebral aneurysms.

Authors:  Qian Wu; Ming-Hua Li
Journal:  BMC Neurol       Date:  2012-07-06       Impact factor: 2.474

Review 9.  Brain Vascular Imaging Techniques.

Authors:  Bàrbara Laviña
Journal:  Int J Mol Sci       Date:  2016-12-30       Impact factor: 5.923

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.