Literature DB >> 10981735

Experimental characterisation of CCD cameras for HREM at 300 kV

.   

Abstract

The modulation transfer function, noise transfer function and detection quantum efficiency of both 1k2 and 2k2 cameras attached to the same 300 kV FEGTEM have been measured. The results show that both the MTF and the DQE of the 2k2 camera are lower than for the 1k2 camera at frequencies above a third of the Nyquist limit. This lower per-pixel performance of the 2k2 camera is primarily a result of the use of a thicker phosphor scintillator. However, MTF and DQE of the 2k2 camera operated as an effective 1k2 camera by using 2 x 2 pixel binning are superior to the 1k2 camera in the medium spatial frequency range.

Entities:  

Year:  2000        PMID: 10981735     DOI: 10.1016/s0304-3991(00)00046-2

Source DB:  PubMed          Journal:  Ultramicroscopy        ISSN: 0304-3991            Impact factor:   2.689


  6 in total

1.  Characterization of a direct detection device imaging camera for transmission electron microscopy.

Authors:  Anna-Clare Milazzo; Grigore Moldovan; Jason Lanman; Liang Jin; James C Bouwer; Stuart Klienfelder; Steven T Peltier; Mark H Ellisman; Angus I Kirkland; Nguyen-Huu Xuong
Journal:  Ultramicroscopy       Date:  2010-03-25       Impact factor: 2.689

2.  Ranking TEM cameras by their response to electron shot noise.

Authors:  Patricia Grob; Derek Bean; Dieter Typke; Xueming Li; Eva Nogales; Robert M Glaeser
Journal:  Ultramicroscopy       Date:  2013-01-29       Impact factor: 2.689

Review 3.  Single-Particle Cryo-EM at Crystallographic Resolution.

Authors:  Yifan Cheng
Journal:  Cell       Date:  2015-04-23       Impact factor: 41.582

4.  Practical factors affecting the performance of a thin-film phase plate for transmission electron microscopy.

Authors:  Radostin Danev; Robert M Glaeser; Kuniaki Nagayama
Journal:  Ultramicroscopy       Date:  2008-12-11       Impact factor: 2.689

5.  An electron counting algorithm improves imaging of proteins with low-acceleration-voltage cryo-electron microscope.

Authors:  Dongjie Zhu; Huigang Shi; Chunling Wu; Xinzheng Zhang
Journal:  Commun Biol       Date:  2022-04-06

6.  Electron counting and beam-induced motion correction enable near-atomic-resolution single-particle cryo-EM.

Authors:  Xueming Li; Paul Mooney; Shawn Zheng; Christopher R Booth; Michael B Braunfeld; Sander Gubbens; David A Agard; Yifan Cheng
Journal:  Nat Methods       Date:  2013-05-05       Impact factor: 28.547

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.