Practical factors affecting the performance of a thin-film phase plate for transmission electron microscopy.

Radostin Danev1, Robert M Glaeser, Kuniaki Nagayama.   

Abstract

A number of practical issues must be addressed when using thin carbon films as quarter-wave plates for Zernike phase-contrast electron microscopy. We describe, for example, how we meet the more stringent requirements that must be satisfied for beam alignment in this imaging mode. In addition we address the concern that one might have regarding the loss of some of the scattered electrons as they pass through such a phase plate. We show that two easily measured parameters, (1) the low-resolution image contrast produced in cryo-EM images of tobacco mosaic virus particles and (2) the fall-off of the envelope function at high resolution, can be used to quantitatively compare the data quality for Zernike phase-contrast images and for defocused bright-field images. We describe how we prepare carbon-film phase plates that are initially free of charging or other effects that degrade image quality. We emphasize, however, that even though the buildup of hydrocarbon contamination can be avoided by heating the phase plates during use, their performance nevertheless deteriorates over the time scale of days to weeks, thus requiring their frequent replacement in order to maintain optimal performance.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19157711      PMCID: PMC3223123          DOI: 10.1016/j.ultramic.2008.12.006

Source DB:  PubMed          Journal:  Ultramicroscopy        ISSN: 0304-3991            Impact factor:   2.689


  18 in total

1.  Transmission electron microscopy with Zernike phase plate.

Authors:  R Danev; K Nagayama
Journal:  Ultramicroscopy       Date:  2001-09       Impact factor: 2.689

2.  Using cryo-EM to measure the dipole potential of a lipid membrane.

Authors:  Liguo Wang; Pulkit S Bose; Fred J Sigworth
Journal:  Proc Natl Acad Sci U S A       Date:  2006-11-20       Impact factor: 11.205

3.  Electron holography of thin amorphous carbon films: measurement of the mean inner potential and a thickness-independent phase shift.

Authors:  Matthias Wanner; David Bach; Dagmar Gerthsen; Ralph Werner; Bernd Tesche
Journal:  Ultramicroscopy       Date:  2005-11-28       Impact factor: 2.689

4.  Electron energy filtering significantly improves amplitude contrast of frozen-hydrated protein at 300kV.

Authors:  Koji Yonekura; Michael B Braunfeld; Saori Maki-Yonekura; David A Agard
Journal:  J Struct Biol       Date:  2006-08-15       Impact factor: 2.867

5.  Single particle analysis based on Zernike phase contrast transmission electron microscopy.

Authors:  Radostin Danev; Kuniaki Nagayama
Journal:  J Struct Biol       Date:  2007-11-06       Impact factor: 2.867

6.  Zernike phase contrast electron microscopy of ice-embedded influenza A virus.

Authors:  Masashi Yamaguchi; Radostin Danev; Kiyoto Nishiyama; Keishin Sugawara; Kuniaki Nagayama
Journal:  J Struct Biol       Date:  2008-01-26       Impact factor: 2.867

Review 7.  X-ray solution scattering (SAXS) combined with crystallography and computation: defining accurate macromolecular structures, conformations and assemblies in solution.

Authors:  Christopher D Putnam; Michal Hammel; Greg L Hura; John A Tainer
Journal:  Q Rev Biophys       Date:  2007-08       Impact factor: 5.318

8.  A formula for the image intensity of phase objects in Zernike mode.

Authors:  Marco Beleggia
Journal:  Ultramicroscopy       Date:  2008-04-03       Impact factor: 2.689

9.  Specimen charging on thin films with one conducting layer: discussion of physical principles.

Authors:  Robert M Glaeser; Kenneth H Downing
Journal:  Microsc Microanal       Date:  2004-12       Impact factor: 4.127

10.  A Novel Phase-contrast Transmission Electron Microscopy Producing High-contrast Topographic Images of Weak objects.

Authors:  R Danev; H Okawara; N Usuda; K Kametani; K Nagayama
Journal:  J Biol Phys       Date:  2002-12       Impact factor: 1.365

View more
  32 in total

1.  Retrofit implementation of Zernike phase plate imaging for cryo-TEM.

Authors:  Michael Marko; Ardean Leith; Chyongere Hsieh; Radostin Danev
Journal:  J Struct Biol       Date:  2011-01-25       Impact factor: 2.867

2.  Methods for testing Zernike phase plates and a report on silicon-based phase plates with reduced charging and improved ageing characteristics.

Authors:  Michael Marko; Xing Meng; Chyongere Hsieh; James Roussie; Christopher Striemer
Journal:  J Struct Biol       Date:  2013-08-28       Impact factor: 2.867

Review 3.  Invited review article: Methods for imaging weak-phase objects in electron microscopy.

Authors:  Robert M Glaeser
Journal:  Rev Sci Instrum       Date:  2013-11       Impact factor: 1.523

4.  Restoration of weak phase-contrast images recorded with a high degree of defocus: the "twin image" problem associated with CTF correction.

Authors:  Kenneth H Downing; Robert M Glaeser
Journal:  Ultramicroscopy       Date:  2008-04-03       Impact factor: 2.689

Review 5.  Reaching the information limit in cryo-EM of biological macromolecules: experimental aspects.

Authors:  Robert M Glaeser; Richard J Hall
Journal:  Biophys J       Date:  2011-05-18       Impact factor: 4.033

6.  Volta potential phase plate for in-focus phase contrast transmission electron microscopy.

Authors:  Radostin Danev; Bart Buijsse; Maryam Khoshouei; Jürgen M Plitzko; Wolfgang Baumeister
Journal:  Proc Natl Acad Sci U S A       Date:  2014-10-20       Impact factor: 11.205

7.  Visualizing Individual RuBisCO and Its Assembly into Carboxysomes in Marine Cyanobacteria by Cryo-Electron Tomography.

Authors:  Wei Dai; Muyuan Chen; Christopher Myers; Steven J Ludtke; B Montgomery Pettitt; Jonathan A King; Michael F Schmid; Wah Chiu
Journal:  J Mol Biol       Date:  2018-08-20       Impact factor: 5.469

8.  Practical Experience with Hole-Free Phase Plates for Cryo Electron Microscopy.

Authors:  Michael Marko; Chyongere Hsieh; Eric Leith; David Mastronarde; Sohei Motoki
Journal:  Microsc Microanal       Date:  2016-11-24       Impact factor: 4.127

9.  Effect of fringe-artifact correction on sub-tomogram averaging from Zernike phase-plate cryo-TEM.

Authors:  Gregory P Kishchenko; Radostin Danev; Rebecca Fisher; Jie He; Chyongere Hsieh; Michael Marko; Haixin Sui
Journal:  J Struct Biol       Date:  2015-07-22       Impact factor: 2.867

10.  Minimizing electrostatic charging of an aperture used to produce in-focus phase contrast in the TEM.

Authors:  Robert M Glaeser; Simone Sassolini; Rossana Cambie; Jian Jin; Stefano Cabrini; Andreas K Schmid; Radostin Danev; Bart Buijsse; Roseann Csencsits; Kenneth H Downing; David M Larson; Dieter Typke; B G Han
Journal:  Ultramicroscopy       Date:  2013-06-08       Impact factor: 2.689

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.