Literature DB >> 10931566

Safety of MRI-guided endovascular guidewire applications.

C Y Liu1, K Farahani, D S Lu, G Duckwiler, A Oppelt.   

Abstract

Magnetic radiofrequency (RF) fields applied during magnetic resonance imaging (MRI) may induce heating in devices made from conductive materials. The present paper reports on theoretical and experimental studies on the RF heating resonance phenomenon of an endovascular guidewire. A nitinol-based guidewire was inserted into a vessel phantom and imaged at 1.5 and 0.2 T with continuous temperature monitoring at the guidewire tip. The heating effects due to different experimental settings were examined. A model is developed for the resonant current and the associated electric field produced by the guidewire acting as an antenna. Temperature increases of up to 17 degrees C were measured while imaging the guidewire at an off-center position in the 1.5 T MR system. Power absorption produced by the resonating wire decreased as the repetition time was increased. No temperature rise was measured at 0.2 T. Considering the potential utility of low-field, open MR systems for MRI-guided endovascular interventions, it is important to be aware of the safety of such applications.

Entities:  

Mesh:

Year:  2000        PMID: 10931566     DOI: 10.1002/1522-2586(200007)12:1<75::aid-jmri8>3.0.co;2-#

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  12 in total

1.  Catheter-based endomyocardial injection with real-time magnetic resonance imaging.

Authors:  Robert J Lederman; Michael A Guttman; Dana C Peters; Richard B Thompson; Jonathan M Sorger; Alexander J Dick; Venkatesh K Raman; Elliot R McVeigh
Journal:  Circulation       Date:  2002-03-19       Impact factor: 29.690

2.  RF Heating of MRI-Assisted Catheter Steering Coils for Interventional MRI.

Authors:  Fabio Settecase; Steven W Hetts; Alastair J Martin; Timothy P L Roberts; Anthony F Bernhardt; Lee Evans; Vincent Malba; Maythem Saeed; Ronald L Arenson; Walter Kucharzyk; Mark W Wilson
Journal:  Acad Radiol       Date:  2010-11-13       Impact factor: 3.173

Review 3.  Cardiovascular interventional magnetic resonance imaging.

Authors:  Robert J Lederman
Journal:  Circulation       Date:  2005-11-08       Impact factor: 29.690

Review 4.  MR-guided endovascular interventions: a comprehensive review on techniques and applications.

Authors:  Sebastian Kos; Rolf Huegli; Georg M Bongartz; Augustinus L Jacob; Deniz Bilecen
Journal:  Eur Radiol       Date:  2007-12-11       Impact factor: 5.315

5.  Heating and safety of a new MR-compatible guidewire prototype versus a standard nitinol guidewire.

Authors:  Malgorzata Wolska-Krawczyk; Martin A Rube; Erwin Immel; Andreas Melzer; Arno Buecker
Journal:  Radiol Phys Technol       Date:  2013-11-08

6.  Parallel transmit excitation at 1.5 T based on the minimization of a driving function for device heating.

Authors:  N Gudino; M Sonmez; Z Yao; T Baig; S Nielles-Vallespin; A Z Faranesh; R J Lederman; M Martens; R S Balaban; M S Hansen; M A Griswold
Journal:  Med Phys       Date:  2015-01       Impact factor: 4.071

7.  Real-time magnetic resonance imaging-guided stenting of aortic coarctation with commercially available catheter devices in Swine.

Authors:  Amish N Raval; James D Telep; Michael A Guttman; Cengizhan Ozturk; Michael Jones; Richard B Thompson; Victor J Wright; William H Schenke; Ranil DeSilva; Ronnier J Aviles; Venkatesh K Raman; Michael C Slack; Robert J Lederman
Journal:  Circulation       Date:  2005-07-25       Impact factor: 29.690

Review 8.  Improving Safety of MRI in Patients with Deep Brain Stimulation Devices.

Authors:  Alexandre Boutet; Clement T Chow; Keshav Narang; Gavin J B Elias; Clemens Neudorfer; Jürgen Germann; Manish Ranjan; Aaron Loh; Alastair J Martin; Walter Kucharczyk; Christopher J Steele; Ileana Hancu; Ali R Rezai; Andres M Lozano
Journal:  Radiology       Date:  2020-06-23       Impact factor: 11.105

Review 9.  Emerging roles for integrated imaging modalities in cardiovascular cell-based therapeutics: a clinical perspective.

Authors:  Peter J Psaltis; Robert D Simari; Martin Rodriguez-Porcel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-09-08       Impact factor: 9.236

10.  RF Heating of Gold Cup and Conductive Plastic Electrodes during Simultaneous EEG and MRI.

Authors:  Mukund Balasubramanian; William M Wells; John R Ives; Patrick Britz; Robert V Mulkern; Darren B Orbach
Journal:  Neurodiagn J       Date:  2017
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.