Literature DB >> 10931560

Safety of strong, static magnetic fields.

J F Schenck1.   

Abstract

Issues associated with the exposure of patients to strong, static magnetic fields during magnetic resonance imaging (MRI) are reviewed and discussed. The history of human exposure to magnetic fields is reviewed, and the contradictory nature of the literature regarding effects on human health is described. In the absence of ferromagnetic foreign bodies, there is no replicated scientific study showing a health hazard associated with magnetic field exposure and no evidence for hazards associated with cumulative exposure to these fields. The very high degree of patient safety in strong magnetic fields is attributed to the small value of the magnetic susceptibility of human tissues and to the lack of ferromagnetic components in these tissues. The wide range of susceptibility values between magnetic materials and human tissues is shown to lead to qualitatively differing behaviors of these materials when they are exposed to magnetic fields. Mathematical expressions are provided for the calculation of forces and torques.

Entities:  

Mesh:

Year:  2000        PMID: 10931560     DOI: 10.1002/1522-2586(200007)12:1<2::aid-jmri2>3.0.co;2-v

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  62 in total

1.  Quantification of adverse events associated with functional MRI scanning and with real-time fMRI-based training.

Authors:  Jon E Hawkinson; Amy J Ross; Sudharshan Parthasarathy; David J Scott; Ella A Laramee; Lainie J Posecion; William R Rekshan; Kristen E Sheau; Nkechi D Njaka; Peter J Bayley; R Christopher deCharms
Journal:  Int J Behav Med       Date:  2012-09

2.  Magnetic resonance imaging protocols for examination of the neurocranium at 3 T.

Authors:  W Schwindt; H Kugel; R Bachmann; S Kloska; T Allkemper; D Maintz; B Pfleiderer; B Tombach; W Heindel
Journal:  Eur Radiol       Date:  2003-07-05       Impact factor: 5.315

Review 3.  Occupational exposure in MRI.

Authors:  D W McRobbie
Journal:  Br J Radiol       Date:  2012-04       Impact factor: 3.039

Review 4.  [Physical interactions in MRI: Some rules of thumb for their reduction].

Authors:  M Mühlenweg; G Schaefers; S Trattnig
Journal:  Radiologe       Date:  2015-08       Impact factor: 0.635

5.  Magnet therapy.

Authors:  Leonard Finegold; Bruce L Flamm
Journal:  BMJ       Date:  2006-01-07

Review 6.  Safety concerns related to magnetic field exposure.

Authors:  Amanda K Andriola Silva; Erica L Silva; E Sócrates T Egito; Artur S Carriço
Journal:  Radiat Environ Biophys       Date:  2006-09-21       Impact factor: 1.925

7.  Subjective acceptance of 7 Tesla MRI for human imaging.

Authors:  Jens M Theysohn; Stefan Maderwald; Oliver Kraff; Christoph Moenninghoff; Mark E Ladd; Susanne C Ladd
Journal:  MAGMA       Date:  2007-12-07       Impact factor: 2.310

Review 8.  [Safety aspects in high-field magnetic resonance imaging].

Authors:  M Mühlenweg; G Schaefers; S Trattnig
Journal:  Radiologe       Date:  2008-03       Impact factor: 0.635

Review 9.  Implementation of a comprehensive MR safety course for medical students.

Authors:  Steffen Sammet; Christina L Sammet
Journal:  J Magn Reson Imaging       Date:  2015-07-14       Impact factor: 4.813

Review 10.  Toward 20 T magnetic resonance for human brain studies: opportunities for discovery and neuroscience rationale.

Authors:  Thomas F Budinger; Mark D Bird; Lucio Frydman; Joanna R Long; Thomas H Mareci; William D Rooney; Bruce Rosen; John F Schenck; Victor D Schepkin; A Dean Sherry; Daniel K Sodickson; Charles S Springer; Keith R Thulborn; Kamil Uğurbil; Lawrence L Wald
Journal:  MAGMA       Date:  2016-05-18       Impact factor: 2.310

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.