Literature DB >> 10921941

Detection of significant bacteriuria by automated urinalysis using flow cytometry.

H Okada1, Y Sakai, S Miyazaki, S Arakawa, Y Hamaguchi, S Kamidono.   

Abstract

A new flow cytometry-based automated urine analyzer, the UF-50, was evaluated for its ability to screen urine samples for significant bacteriuria. One hundred eighty-six urine specimens from patients attending an outpatient clinic of a university-based hospital were examined. The results obtained with the UF-50 were compared with those obtained by conventional quantitative urine culture. The UF-50 detected significant bacteriuria with a sensitivity of 83.1%, a specificity of 76.4%, a positive predictive value of 62.0%, a negative predictive value of 90.7%, and an accuracy of 78.5%. These results are comparable to those obtained by previously reported screening procedures. Besides detecting significant bacteriuria, the UF-50 can also perform routine urinalysis, including measurement of concentrations of red blood cells, white blood cells, epithelial cells, and casts, within 70 s. This capability renders this new flow cytometry-based urine analyzer superior to previously reported rapid screening methods.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10921941      PMCID: PMC87132     

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  5 in total

1.  Evaluation of Clinitek 200 and Rapimat II/T for screening for urinary tract infection.

Authors:  R A Bowman; T V Riley
Journal:  J Clin Pathol       Date:  1991-01       Impact factor: 3.411

2.  Simplified technique for detection of significant bacteriuria by microscopic examination of urine.

Authors:  C L Cardoso; C B Muraro; V L Siqueira; M Guilhermetti
Journal:  J Clin Microbiol       Date:  1998-03       Impact factor: 5.948

3.  Problems of spectrum and bias in evaluating the efficacy of diagnostic tests.

Authors:  D F Ransohoff; A R Feinstein
Journal:  N Engl J Med       Date:  1978-10-26       Impact factor: 91.245

Review 4.  Clinical relevance of culture versus screens for the detection of microbial pathogens in urine specimens.

Authors:  J A Kellogg; J P Manzella; S N Shaffer; B B Schwartz
Journal:  Am J Med       Date:  1987-10       Impact factor: 4.965

5.  Clinical evaluation of a rapid diagnostic screen (URISCREEN) for bacteriuria in children.

Authors:  L S Palmer; I Richards; W E Kaplan
Journal:  J Urol       Date:  1997-02       Impact factor: 7.450

  5 in total
  13 in total

1.  Unsatisfactory performance of flow cytometer UF-100 and urine strips in predicting outcome of urine cultures.

Authors:  Z Zaman; S Roggeman; J Verhaegen
Journal:  J Clin Microbiol       Date:  2001-11       Impact factor: 5.948

2.  Performance of urinary flow cytometry in predicting outcome of urine cultures.

Authors:  Joris R Delanghe; Michel R Langlois; Birgitte Wuyts; Marc L De Buyzere
Journal:  J Clin Microbiol       Date:  2002-06       Impact factor: 5.948

3.  Bacteriuria screening by automated whole-field-image-based microscopy reduces the number of necessary urine cultures.

Authors:  Rosanna Falbo; M Roberta Sala; Silvia Signorelli; Natascia Venturi; Stefano Signorini; Paolo Brambilla
Journal:  J Clin Microbiol       Date:  2012-01-11       Impact factor: 5.948

4.  Testing by Sysmex UF-100 flow cytometer and with bacterial culture in a diagnostic laboratory: a comparison.

Authors:  R Evans; M M Davidson; L R W Sim; A J Hay
Journal:  J Clin Pathol       Date:  2006-06       Impact factor: 3.411

5.  Rapid screening of urine specimens for bacteriuria by the cellenium system.

Authors:  Preeti Pancholi; Kathleen Pavletich; Phyllis Della-Latta
Journal:  J Clin Microbiol       Date:  2005-10       Impact factor: 5.948

6.  Screening for urinary tract infection with the Sysmex UF-1000i urine flow cytometer.

Authors:  Maarten A C Broeren; Semiha Bahçeci; Huib L Vader; Niek L A Arents
Journal:  J Clin Microbiol       Date:  2011-01-19       Impact factor: 5.948

7.  Screening of urine samples by flow cytometry reduces the need for culture.

Authors:  Santra Jolkkonen; Eeva-Liisa Paattiniemi; Pauliina Kärpänoja; Hannu Sarkkinen
Journal:  J Clin Microbiol       Date:  2010-06-30       Impact factor: 5.948

8.  Enumeration of bacterial cell numbers and detection of significant bacteriuria by use of a new flow cytometry-based device.

Authors:  Hiroshi Okada; Toshiro Shirakawa; Akinobu Gotoh; Yutaka Kamiyama; Satoru Muto; Hisamitsu Ide; Yukio Hamaguchi; Shigeo Horie
Journal:  J Clin Microbiol       Date:  2006-10       Impact factor: 5.948

9.  Quantitative detection of Escherichia coli from urine of patients with bacteriuria by real-time PCR.

Authors:  Nobuyuki Hinata; Toshiro Shirakawa; Hiroshi Okada; Katsumi Shigemura; Sadao Kamidono; Akinobu Gotoh
Journal:  Mol Diagn       Date:  2004

10.  Standardization of isothermal microcalorimetry in urinary tract infection detection by using artificial urine.

Authors:  Gernot Bonkat; Olivier Braissant; Malte Rieken; Anna Solokhina; Andreas F Widmer; Reno Frei; Andre van der Merwe; Stephen Wyler; Thomas C Gasser; Alexander Bachmann
Journal:  World J Urol       Date:  2012-07-26       Impact factor: 4.226

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.