Literature DB >> 10898874

Advanced biomaterials used for a new telescopic retainer for removable dentures.

P Weigl1, H C Lauer.   

Abstract

Telescopic retainers with conical ceramic abutment crowns and electroplated gold copings define a new retainer for removable dentures exhibiting favorable tribological properties that could offer clinical advantages. The objective of this study was to evaluate the clinical effects of this retainer. To do so, a novel treatment modality was developed based on intraoral bonding of the copings to the framework in order to be able to realize, in a clinical setting, the retainer function based on a precision fit. A total of 32 patients wearing 33 dentures (16 mandibular, 17 maxillary; period of risk [months]: minimum = 3; maximum = 58; mean = 27.6), supported by 147 abutments (83 natural teeth, 64 implants) with ceramic abutment crowns (IPS Empress 1, IPS Empress 2, InCeram, Procera, CerAdapt; CeraBase) were followed at 6-month intervals. The ceramic abutment crowns showed low plaque accumulation (mean PI = 17.3%). The gingival tissues around natural abutments were generally free of inflammation; so was the mucosa around the implants (mean SBI = 4.9%). Denture adhesion and occlusion did not change, and there were no rocking movements. The mobility (as determined by Periotest) of 29 teeth was reduced in a highly significant manner within 6 months (t test, p < 0.001). Osseointegration was preserved for all implants. One abutment loosened. Six Empress 1 ceramic copings failed (94.6% Kaplan-Meier survival rate), and one abutment tooth was lost (99.2% survival rate). All patients reported problem-free handling, no rocking movements, and constant adhesion. The adhesive strength of one denture was too low at insertion. 94% of the patients experienced no problems with oral hygiene. The retainer examined has relevant clinical advantages and meets geriatric requirements for removable dentures. Copyright 2000 John Wiley & Sons, Inc.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10898874     DOI: 10.1002/1097-4636(2000)53:4<337::aid-jbm7>3.0.co;2-7

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  10 in total

1.  Parameters affecting retentive force of electroformed double-crown systems.

Authors:  Florian Beuer; Daniel Edelhoff; Wolfgang Gernet; Michael Naumann
Journal:  Clin Oral Investig       Date:  2009-04-03       Impact factor: 3.573

2.  Wear behavior of different double-crown systems.

Authors:  Jörg Engels; Oliver Schubert; Jan-Frederik Güth; Matthias Hoffmann; Christian Jauernig; Kurt Erdelt; Michael Stimmelmayr; Florian Beuer
Journal:  Clin Oral Investig       Date:  2012-05-10       Impact factor: 3.573

3.  Retention forces of 14-unit zirconia telescopic prostheses with six double crowns made from zirconia--an in vitro study.

Authors:  Julian Groesser; Caroline Sachs; Philipp Heiß; Markus Stadelmann; Kurt Erdelt; Florian Beuer
Journal:  Clin Oral Investig       Date:  2013-08-21       Impact factor: 3.573

4.  Electroplated telescopic retainers with zirconia primary crowns: 3-year results from a randomized clinical trial.

Authors:  Franz Sebastian Schwindling; Franziska Lehmann; Sophia Terebesi; Nicoleta Corcodel; Andreas Zenthöfer; Peter Rammelsberg; Thomas Stober
Journal:  Clin Oral Investig       Date:  2017-02-11       Impact factor: 3.573

5.  Retention and surface changes of zirconia primary crowns with secondary crowns of different materials.

Authors:  Işıl Turp; Ergün Bozdağ; Emin Sünbüloğlu; Cem Kahruman; Ibrahim Yusufoğlu; Gülsen Bayraktar
Journal:  Clin Oral Investig       Date:  2014-01-31       Impact factor: 3.573

6.  Long-term behavior of double crown retained dentures with metal and metal-free secondary crowns and frameworks made of Vectris(©) on all-ceramic primary crowns: a prospective, randomized clinical trial up to 14 years.

Authors:  T Zahn; B Zahn; S Janko; P Weigl; S Gerhardt-Szép; H C Lauer
Journal:  Clin Oral Investig       Date:  2015-09-23       Impact factor: 3.573

7.  Implant placement under existing removable dental prostheses and its effect on masticatory performance.

Authors:  S Wolfart; K Wolf; S Brunzel; M Wolfart; A Caliebe; M Kern
Journal:  Clin Oral Investig       Date:  2016-03-03       Impact factor: 3.573

8.  Locator® versus ceramic/electroplated double-crown attachments: a prospective study on the intraindividual comparison of implant-supported mandibular prostheses.

Authors:  Silvia Brandt; Jan Brandt; Ali-Reza Ketabi; Hans-Christoph Lauer; Anna Kunzmann
Journal:  Clin Oral Investig       Date:  2018-05-19       Impact factor: 3.573

9.  Electroplated and cast double crown-retained removable dental prostheses: 6-year results from a randomized clinical trial.

Authors:  Thomas Stober; Justo Lorenzo Bermejo; Anne-Christiane Séché; Franziska Lehmann; Peter Rammelsberg; Wolfgang Bömicke
Journal:  Clin Oral Investig       Date:  2014-10-11       Impact factor: 3.573

10.  Clinical outcome of double crown-retained implant overdentures with zirconia primary crowns.

Authors:  Sven Rinke; Ralf Buergers; Dirk Ziebolz; Matthias Roediger
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.