PURPOSE: We evaluated improvement in the rate of prostate cancer detection when using an extensive biopsy protocol involving peripheral cores. MATERIALS AND METHODS: We prospectively evaluated 303 consecutive men who underwent transrectal ultrasound guided biopsy due to elevated prostate specific antigen (PSA) and/or abnormal digital rectal examination. Ten biopsies were performed, including at least 5 at the base and middle of each lobe. In addition to standard biopsy at a 45-degree angle, a more peripheral 30-degree angle biopsy was obtained. At the apex only 1 standard biopsy was done. However, when prostate volume was greater than 50 cm.3, an additional peripheral biopsy was obtained at the apex. RESULTS: The complication rate in this biopsy protocol was 1% (3 patients). Prostate cancer was detected in 118 of the 303 men (38. 9%). Overall this extensive protocol resulted in 6.6% improvement in the detection rate. Improvement was 6.5% in men with PSA 10 ng./ml. or less and 7% in those with PSA greater than 10 (not significant). CONCLUSIONS: Increasing the number of biopsy cores and improving prostate peripheral zone sampling resulted in a significant improvement in the detection of prostate cancer.
PURPOSE: We evaluated improvement in the rate of prostate cancer detection when using an extensive biopsy protocol involving peripheral cores. MATERIALS AND METHODS: We prospectively evaluated 303 consecutive men who underwent transrectal ultrasound guided biopsy due to elevated prostate specific antigen (PSA) and/or abnormal digital rectal examination. Ten biopsies were performed, including at least 5 at the base and middle of each lobe. In addition to standard biopsy at a 45-degree angle, a more peripheral 30-degree angle biopsy was obtained. At the apex only 1 standard biopsy was done. However, when prostate volume was greater than 50 cm.3, an additional peripheral biopsy was obtained at the apex. RESULTS: The complication rate in this biopsy protocol was 1% (3 patients). Prostate cancer was detected in 118 of the 303 men (38. 9%). Overall this extensive protocol resulted in 6.6% improvement in the detection rate. Improvement was 6.5% in men with PSA 10 ng./ml. or less and 7% in those with PSA greater than 10 (not significant). CONCLUSIONS: Increasing the number of biopsy cores and improving prostate peripheral zone sampling resulted in a significant improvement in the detection of prostate cancer.
Authors: Bruce J Trock; Michelle J Brotzman; Leslie A Mangold; Joseph W Bigley; Jonathan I Epstein; David McLeod; Eric A Klein; J Stephen Jones; Songbai Wang; Theresa McAskill; Jyoti Mehrotra; Bhargavi Raghavan; Alan W Partin Journal: BJU Int Date: 2011-11-11 Impact factor: 5.588
Authors: Jennifer K Logan; Soroush Rais-Bahrami; Baris Turkbey; Andrew Gomella; Hayet Amalou; Peter L Choyke; Bradford J Wood; Peter A Pinto Journal: BJU Int Date: 2014-05-22 Impact factor: 5.588