Literature DB >> 26328196

When prostate cancer remains undetectable: The dilemma.

Mahmoud Othman Mustafa1, Louis Pisters2.   

Abstract

Since the first report on the efficacy of sextant biopsy under transrectal ultrasound guidance, there have been many modifications related to the total number of cores and the localization of biopsies to improve the prostate cancer (PCa) detection rate. The 2010 National Comprehensive Cancer Network Early PCa Detection Guidelines noted the 12-core biopsy scheme as the standard. However, this extended biopsy scheme still fails to detect 20% of high-grade PCa that can be detected by detailed pathological evaluation of radical prostatectomy; therefore, there is need for saturation biopsies. The existence of suspicions of PCa after previous negative biopsy or biopsies represents a valid indication for saturation biopsy. There has been no significant increment in morbidity or in insignificant PCa detection rates when a saturation biopsy scheme was used with an extended biopsy scheme. Along with the improvement in the PCa detection rate, accurate oncological mapping of PCa is another important consideration of saturation biopsies. The ideal number of cores and the diagnostic value of saturation biopsy after the failure of initial therapy are some of the issues that need to be addressed. Preliminary reports have shown that magnetic resonance imaging can improve the PCa detection rate, save patients from unnecessary biopsies, and decrease the need for a high number of cores; however, multiple limitations continue to exist.

Entities:  

Keywords:  Prostate; prostate biopsy; prostate cancer

Year:  2015        PMID: 26328196      PMCID: PMC4548656          DOI: 10.5152/tud.2015.91249

Source DB:  PubMed          Journal:  Turk J Urol        ISSN: 2149-3235


  65 in total

1.  NCCN clinical practice guidelines in oncology: prostate cancer early detection.

Authors:  Mark H Kawachi; Robert R Bahnson; Michael Barry; J Erik Busby; Peter R Carroll; H Ballentine Carter; William J Catalona; Michael S Cookson; Jonathan I Epstein; Ruth B Etzioni; Veda N Giri; George P Hemstreet; Richard J Howe; Paul H Lange; Hans Lilja; Kevin R Loughlin; James Mohler; Judd Moul; Robert B Nadler; Stephen G Patterson; Joseph C Presti; Antoinette M Stroup; Robert Wake; John T Wei
Journal:  J Natl Compr Canc Netw       Date:  2010-02       Impact factor: 11.908

2.  Outcome of sextant biopsy according to gland volume.

Authors:  P I Karakiewicz; M Bazinet; A G Aprikian; C Trudel; S Aronson; M Nachabé; F Péloquint; J Dessureault; M S Goyal; L R Bégin; M M Elhilali
Journal:  Urology       Date:  1997-01       Impact factor: 2.649

Review 3.  Safety and morbidity of first and repeat transrectal ultrasound guided prostate needle biopsies: results of a prospective European prostate cancer detection study.

Authors:  B Djavan; M Waldert; A Zlotta; P Dobronski; C Seitz; M Remzi; A Borkowski; C Schulman; M Marberger
Journal:  J Urol       Date:  2001-09       Impact factor: 7.450

4.  Three-Tesla magnetic resonance-guided prostate biopsy in men with increased prostate-specific antigen and repeated, negative, random, systematic, transrectal ultrasound biopsies: detection of clinically significant prostate cancers.

Authors:  Caroline M A Hoeks; Martijn G Schouten; Joyce G R Bomers; Stefan P Hoogendoorn; Christina A Hulsbergen-van de Kaa; Thomas Hambrock; Henk Vergunst; J P Michiel Sedelaar; Jurgen J Fütterer; Jelle O Barentsz
Journal:  Eur Urol       Date:  2012-02-01       Impact factor: 20.096

5.  Needle biopsies on autopsy prostates: sensitivity of cancer detection based on true prevalence.

Authors:  Gabriel P Haas; Nicolas Barry Delongchamps; Richard F Jones; Vishal Chandan; Angel M Serio; Andrew J Vickers; Mary Jumbelic; Gregory Threatte; Rus Korets; Hans Lilja; Gustavo de la Roza
Journal:  J Natl Cancer Inst       Date:  2007-09-25       Impact factor: 13.506

6.  Diagnostic accuracy of extended biopsies for the staging of microfocal prostate cancers in autopsy specimen.

Authors:  N B Delongchamps; G de la Roza; V Chandan; R Jones; G Threatte; M Jumbelic; G P Haas
Journal:  Prostate Cancer Prostatic Dis       Date:  2008-07-15       Impact factor: 5.554

7.  Improved detection of clinically significant, curable prostate cancer with systematic 12-core biopsy.

Authors:  Herb Singh; Eduardo I Canto; Shahrokh F Shariat; Dov Kadmon; Brian J Miles; Thomas M Wheeler; Kevin M Slawin
Journal:  J Urol       Date:  2004-03       Impact factor: 7.450

8.  Parasagittal biopsies add minimal information in repeat saturation prostate biopsy.

Authors:  Amit R Patel; J Stephen Jones; John Rabets; Gerard DeOreo; Craig D Zippe
Journal:  Urology       Date:  2004-01       Impact factor: 2.649

9.  Clinical application of transrectal ultrasonography and prostate specific antigen in the search for prostate cancer.

Authors:  W H Cooner; B R Mosley; C L Rutherford; J H Beard; H S Pond; R B Bass; W J Terry
Journal:  J Urol       Date:  1988-04       Impact factor: 7.450

10.  The appearance of prostate cancer on transrectal ultrasonography: correlation of imaging and pathological examinations.

Authors:  K Shinohara; T M Wheeler; P T Scardino
Journal:  J Urol       Date:  1989-07       Impact factor: 7.450

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.