Personal ultrasound imager: abdominal aortic aneurysm screening.

C J Bruce1, P C Spittell, S C Montgomery, K R Bailey, A J Tajik, J B Seward.   

Abstract

BACKGROUND: Miniaturized ultrasonographic machines (2.5-MHz curved-array transducer connected to a compact 2.6-kg console), termed personal ultrasound imagers (PUIs), may enable detection of occult abdominal aortic aneurysms (AAAs).
OBJECTIVES: Our goals were to determine whether a PUI is capable of screening for AAAs and to compare the results with an established screening examination with standard echocardiography (SE).
METHODS: One hundred twenty-five patients (aged >70 years) with hypertension who were referred for transthoracic echocardiography were enrolled. After SE, a focused screening with a PUI examination was performed by a blinded sonographer. An AAA was defined as a focal enlargement of the aorta >30 mm. Results and the length of time to image the aorta were compared for both tests.
RESULTS: We studied 64 men and 61 women (aged 76.8 +/- 5 years; mean blood pressures: systolic 145.7 +/- 18 and diastolic 78.6 +/- 10; body surface area 1.9 +/- 0.2 m(2)). The mean time for SE was 2.9 +/- 1.5 minutes and for the PUI examination was 4.6 +/- 2.3 minutes. By using SE as the gold standard, the sensitivity and specificity of the PUI were 91% and 96%, respectively. The positive predictive value of the PUI was 71%, and the negative predictive value was 99%.
CONCLUSION: A PUI can be used to screen for occult AAAs as an extension of the physical examination. Results are comparable to an established screening strategy that uses more expensive, nonportable echocardiographic equipment.

Entities:  

Mesh:

Year:  2000        PMID: 10887352     DOI: 10.1067/mje.2000.107797

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  12 in total

1.  The "ultrasonic stethoscope": is it of clinical value?

Authors:  A Salustri; P Trambaiolo
Journal:  Heart       Date:  2003-07       Impact factor: 5.994

2.  Ultrasound stethoscopy: a renaissance of the physical examination?

Authors:  J R T C Roelandt
Journal:  Heart       Date:  2003-09       Impact factor: 5.994

3.  Evaluation of image quality of personal ultrasound imager: Comparison with the conventional machine.

Authors:  Yan Ling Wen; Masatoshi Kudo; Kiyoshi Maekawa; Toshihiko Kawasaki; Hobyung Chung; Yasunori Minami; Yoichiro Suetomi; Hirokazu Onda; Masayuki Kitano; Shigenaga Matsui; Mayumi Eguchi; Ai Kuwaguchi; Kumiko Kawabata
Journal:  J Med Ultrason (2001)       Date:  2002-06       Impact factor: 1.314

Review 4.  Out of hospital point of care ultrasound: current use models and future directions.

Authors:  B P Nelson; A Sanghvi
Journal:  Eur J Trauma Emerg Surg       Date:  2015-02-10       Impact factor: 3.693

5.  Evaluation of a hand carried cardiac ultrasound device in an outpatient cardiology clinic.

Authors:  E C Vourvouri; D Poldermans; J W Deckers; G E Parharidis; J R T C Roelandt
Journal:  Heart       Date:  2005-02       Impact factor: 5.994

6.  Office-based ultrasound screening for abdominal aortic aneurysm.

Authors:  Beau Blois
Journal:  Can Fam Physician       Date:  2012-03       Impact factor: 3.275

7.  Portable spectral Doppler echocardiographic device: overcoming limitations.

Authors:  J Quiles; M A García-Fernández; P B Almeida; E Pérez-David; J Bermejo; M Moreno; P Avanzas
Journal:  Heart       Date:  2003-09       Impact factor: 5.994

8.  Assessment of image quality of contrast-enhanced power doppler imaging in hepatocellular carcinoma with the personal ultrasound imager: Comparison with the conventional machine.

Authors:  Yan Ling Wen; Masatoshi Kudo; Yasunori Minami; Hobyung Chung; Yoichiro Suetomi; Hirokazu Onda; Masayuki Kitano; Toshihiko Kawasaki; Kiyoshi Maekawa
Journal:  J Med Ultrason (2001)       Date:  2003-03       Impact factor: 1.314

9.  Screening for abdominal aortic aneurysms in men: a Canadian perspective using Monte Carlo-based estimates.

Authors:  Bernard Montreuil; James Brophy
Journal:  Can J Surg       Date:  2008-02       Impact factor: 2.089

10.  Clinical utility and cost effectiveness of a personal ultrasound imager for cardiac evaluation during consultation rounds in patients with suspected cardiac disease.

Authors:  E C Vourvouri; L Y Koroleva; F J Ten Cate; D Poldermans; A F L Schinkel; R T van Domburg; W B Vletter; J R T C Roelandt
Journal:  Heart       Date:  2003-07       Impact factor: 5.994

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.