Literature DB >> 27285152

Assessment of image quality of contrast-enhanced power doppler imaging in hepatocellular carcinoma with the personal ultrasound imager: Comparison with the conventional machine.

Yan Ling Wen1,2, Masatoshi Kudo1, Yasunori Minami1, Hobyung Chung1, Yoichiro Suetomi1, Hirokazu Onda1, Masayuki Kitano1, Toshihiko Kawasaki1, Kiyoshi Maekawa3.   

Abstract

OBJECTIVE: To evaluate the usefulness of contrast-enhanced power Doppler imaging with the personal ultrasound imager in depicting intratumoral vascularity in hepatocellular carcinoma.
MATERIALS AND METHODS: Contrast-enhanced power Doppler imaging was used to examine 52 hepatocellular carcinoma nodules in 29 patients, using both the personal ultrasound imager and the conventional ultrasound machine in combination with intravenous injection of Levovist(®). Results obtained using dynamic CT were used as the gold standard. The ability of the personal ultrasound imager to detect intratumoral vascularity was compared with that of the conventional ultrasound machine, and the usefulness of the personal ultrasound imager in assessing therapeutic effect after nonsurgical treatment was compared with that of dynamic CT at the same time.
RESULTS: The personal ultrasound imager and the conventional ultrasound machine, using the fundamental power Doppler imaging mode (p=0.13) and contrast-enhanced power Doppler imaging mode (p=0.41), did not differ significantly in depicting the vascularity of the 52 hepatocellular carcinomas. The sensitivity, specificity, and accuracy of contrast-enhanced power Doppler imaging on the personal ultrasound imager were 95.5%, 87.5%, and 94.2%, respectively, in close agreement with results obtained using dynamic CT. After the 22 hepatocellular carcinomas were treated, the personal ultrasound imager provided diagnostic accuracy of 90.9% on residual tumors when compared with results obtained by dynamic CT, and results obtained using the conventional ultrasound machine were similar.
CONCLUSION: The highly portable personal ultrasound imager using Levovist(®)-enhanced power Doppler imaging can clearly depict the intratumoral vascularity of hepatocellular carcinoma nodules before and after treatment, achieving results very close to those obtained using the conventional diagnostic ultrasound machine. The personal ultrasound imager is an alternative to the conventional ultrasound machine for depicting tumor vascularity.

Entities:  

Keywords:  contrast medium; hepatocellular carcinoma; power Doppler imaging; ultrasound

Year:  2003        PMID: 27285152     DOI: 10.1007/BF02485167

Source DB:  PubMed          Journal:  J Med Ultrason (2001)        ISSN: 1346-4523            Impact factor:   1.314


  21 in total

1.  Evaluation of posttreatment response of hepatocellular carcinoma with contrast-enhanced coded phase-inversion harmonic US: comparison with dynamic CT.

Authors:  H Ding; M Kudo; H Onda; Y Suetomi; Y Minami; H Chung; T Kawasaki; K Maekawa
Journal:  Radiology       Date:  2001-12       Impact factor: 11.105

2.  Morphological diagnosis of hepatocellular carcinoma: special emphasis on intranodular hemodynamic imaging.

Authors:  M Kudo
Journal:  Hepatogastroenterology       Date:  1998-08

Review 3.  Power Doppler sonography: general principles, clinical applications, and future prospects.

Authors:  C Martinoli; L E Derchi; G Rizzatto; L Solbiati
Journal:  Eur Radiol       Date:  1998       Impact factor: 5.315

Review 4.  Power Doppler: it's a good thing.

Authors:  K J Murphy; J M Rubin
Journal:  Semin Ultrasound CT MR       Date:  1997-02       Impact factor: 1.875

5.  Ultrasound contrast agents in liver imaging.

Authors:  E Leen; C S McArdle
Journal:  Clin Radiol       Date:  1996-02       Impact factor: 2.350

6.  Ultrasound contrast enhancement of tumours.

Authors:  D Cosgrove
Journal:  Clin Radiol       Date:  1996-02       Impact factor: 2.350

7.  Hepatocellular carcinoma treated with percutaneous radio-frequency ablation: usefulness of power Doppler US with a microbubble contrast agent in evaluating therapeutic response-preliminary results.

Authors:  D Choi; H K Lim; S H Kim; W J Lee; H J Jang; J Y Lee; S W Paik; K C Koh; J H Lee
Journal:  Radiology       Date:  2000-11       Impact factor: 11.105

Review 8.  Imaging diagnosis of hepatocellular carcinoma and premalignant/borderline lesions.

Authors:  M Kudo
Journal:  Semin Liver Dis       Date:  1999       Impact factor: 6.115

9.  Power Doppler imaging of hepatic tumours: differential diagnosis between hepatocellular carcinoma and metastatic adenocarcinoma.

Authors:  T Kawasaki; T Itani; H Nakase; J Mimura; H Komori; K Sugimoto
Journal:  J Gastroenterol Hepatol       Date:  1998-11       Impact factor: 4.029

10.  Hepatocellular carcinoma: power Doppler US with a contrast agent--preliminary results.

Authors:  A Y Kim; B I Choi; T K Kim; J K Han; E J Yun; K Y Lee; M C Han
Journal:  Radiology       Date:  1998-10       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.