Literature DB >> 10796375

Umbilical artery catheters in the newborn: effects of position of the catheter tip.

K J Barrington1.   

Abstract

BACKGROUND: This section is under preparation and will be included in the next issue.
OBJECTIVES: To determine whether the position of the tip of an umbilical arterial catheter influences the frequency of ischemic events, aortic thrombosis, intraventricular hemorrhage, mortality or necrotising enterocolitis in newborn infants. SEARCH STRATEGY: Randomized and quasi randomized controlled trials of umbilical catheterization use were obtained from the following sources: 1. Effective Care of the Newborn Infant, edited by JC Sinclair and MB Bracken. 2. Medline Search using Melvyl Medline Plus and the keyword headings 'Umbilic#', 'Catheter#' and subject heading 'Infant, Newborn' 3. Search of personal data files SELECTION CRITERIA: Randomized trials in newborn infants of any birthweight or gestation. Comparison of high catheter placement with the tip above the diaphragm to a lower position just above the aortic bifurcation. Clinically important end points such as ischemic events or aortic thrombosis. DATA COLLECTION AND ANALYSIS: Five randomized controlled trials and one alternate assignment study had sufficiently detailed data to allow interpretation. MAIN
RESULTS: High placed umbilical artery catheters are associated with a lower incidence of clinical vascular complications, without an increase in any adverse sequelae. Intraventricular hemorrhage rates, death and necrotising enterocolitis are not more frequent with high compared to low catheters. REVIEWER'S
CONCLUSIONS: There appears to be no evidence to support the use of low placed umbilical artery catheters. High catheters should be used exclusively.

Entities:  

Mesh:

Year:  2000        PMID: 10796375      PMCID: PMC7038652          DOI: 10.1002/14651858.CD000505

Source DB:  PubMed          Journal:  Cochrane Database Syst Rev        ISSN: 1361-6137


  10 in total

1.  Relationship of intraventricular hemorrhage or death with the level of umbilical artery catheter placement: a multicenter randomized clinical trial. Umbilical Artery Catheter Trial Study Group.

Authors: 
Journal:  Pediatrics       Date:  1992-12       Impact factor: 7.124

2.  Umbilical artery catheters: high, low, or no.

Authors:  M S Harris; G A Little
Journal:  J Perinat Med       Date:  1978       Impact factor: 1.901

Review 3.  Umbilical artery catheters in the newborn: effects of position of the catheter tip.

Authors:  K J Barrington
Journal:  Cochrane Database Syst Rev       Date:  2000

4.  Sonographic detection of neonatal umbilical-artery thrombosis: clinical correlation.

Authors:  J J Seibert; B J Taylor; S L Williamson; B J Williams; J S Szabo; S L Corbitt
Journal:  AJR Am J Roentgenol       Date:  1987-05       Impact factor: 3.959

5.  Randomized trial of umbilical arterial catheter position: clinical outcome.

Authors:  S T Kempley; S Bennett; B G Loftus; D Cooper; H R Gamsu
Journal:  Acta Paediatr       Date:  1993-02       Impact factor: 2.299

6.  Aortic thrombosis after umbilical artery catheterization in neonates: prevalence of complications on long-term follow-up.

Authors:  J J Seibert; F J Northington; J F Miers; B J Taylor
Journal:  AJR Am J Roentgenol       Date:  1991-03       Impact factor: 3.959

7.  Randomised trial of umbilical arterial catheter position: Doppler ultrasound findings.

Authors:  S T Kempley; H R Gamsu
Journal:  Arch Dis Child       Date:  1992-07       Impact factor: 3.791

8.  Low positioning of umbilical-artery catheters increases associated complications in newborn infants.

Authors:  S T Mokrohisky; R L Levine; J D Blumhagen; R L Wesenberg; M A Simmons
Journal:  N Engl J Med       Date:  1978-09-14       Impact factor: 91.245

9.  The association of heparin exposure with intraventricular hemorrhage among very low birth weight infants.

Authors:  M H Malloy; G R Cutter
Journal:  J Perinatol       Date:  1995 May-Jun       Impact factor: 2.521

10.  Umbilical artery catheterization in newborns. I. Thrombosis in relation to catheter type and position.

Authors:  G Wesström; O Finnström; G Stenport
Journal:  Acta Paediatr Scand       Date:  1979-07
  10 in total
  18 in total

1.  Validation of oxygen saturation monitoring in neonates.

Authors:  Shyang-Yun Pamela K Shiao; Ching-Nan Ou
Journal:  Am J Crit Care       Date:  2007-03       Impact factor: 2.228

2.  Antithrombotic therapy in neonates and children: Antithrombotic Therapy and Prevention of Thrombosis, 9th ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines.

Authors:  Paul Monagle; Anthony K C Chan; Neil A Goldenberg; Rebecca N Ichord; Janna M Journeycake; Ulrike Nowak-Göttl; Sara K Vesely
Journal:  Chest       Date:  2012-02       Impact factor: 9.410

3.  Simple measurements to place umbilical catheters using surface anatomy.

Authors:  A O Gupta; M R Peesay; J Ramasethu
Journal:  J Perinatol       Date:  2015-01-22       Impact factor: 2.521

Review 4.  Sonographic features of umbilical catheter-related complications.

Authors:  Swathi Selvam; Terry Humphrey; Helen Woodley; Sharon English; Jeannette K Kraft
Journal:  Pediatr Radiol       Date:  2018-08-04

Review 5.  A critical analysis of risk factors for necrotizing enterocolitis.

Authors:  Allison Thomas Rose; Ravi Mangal Patel
Journal:  Semin Fetal Neonatal Med       Date:  2018-08-01       Impact factor: 3.926

6.  [Arterial and central venous catheters in neonates and infants].

Authors:  M Stocker; T M Berger
Journal:  Anaesthesist       Date:  2006-08       Impact factor: 1.041

Review 7.  Neonatal hypertension: cases, causes, and clinical approach.

Authors:  Michelle C Starr; Joseph T Flynn
Journal:  Pediatr Nephrol       Date:  2018-05-28       Impact factor: 3.714

Review 8.  Umbilical artery catheters in the newborn: effects of position of the catheter tip.

Authors:  K J Barrington
Journal:  Cochrane Database Syst Rev       Date:  2000

9.  Late Presentation of Fulminant Necrotizing Enterocolitis in a Child with Hyperinsulinism on Octreotide Therapy.

Authors:  Colin Patrick Hawkes; N Scott Adzick; Andrew A Palladino; Diva D De León
Journal:  Horm Res Paediatr       Date:  2016-02-12       Impact factor: 2.852

10.  Poor accuracy of methods currently used to determine umbilical catheter insertion length.

Authors:  Gerdina H Verheij; Arjan B Te Pas; Ruben S G M Witlox; Vivianne E H J Smits-Wintjens; Frans J Walther; Enrico Lopriore
Journal:  Int J Pediatr       Date:  2010-05-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.