Literature DB >> 1437429

Relationship of intraventricular hemorrhage or death with the level of umbilical artery catheter placement: a multicenter randomized clinical trial. Umbilical Artery Catheter Trial Study Group.

.   

Abstract

Umbilical artery catheters are frequently used in the care of very low birth weight neonates to monitor arterial blood gas values. Historically, catheters with the tip placed low, in the abdominal aorta, have been associated with an increased risk of peripheral vascular complications. Recently, a report suggested that catheters placed high, in the thoracic aorta, were associated with an increased risk of intraventricular hemorrhage. To determine whether there is an association between the placement of an umbilical artery catheter high, in the thoracic aorta, and the occurrence of intraventricular hemorrhage (grades II through IV) or death within the first 5 days of life, a multicenter randomized trial was conducted. Nine hundred seventy neonates weighing 500 through 1499 g were randomly assigned to receive either high catheters, in the thoracic aorta closest to the sixth to eight thoracic vertebra, or low catheters, in the abdominal aorta closest to the third to fifth lumbar vertebra. The incidence of the primary outcome (intraventricular hemorrhage grades II through IV and/or death) was 25.8% among newborns with high catheters and 23.1% in those with low catheters (relative risk = 1.12, 95% confidence interval = 0.89, 1.39). However, a significant interaction was observed between the level of catheter placement and birth weight for neonates weighing 750 through 999 g and those weighing 1000 through 1499 g. The subgroup of neonates weighing 750 to 1000 g had a relative risk of the primary outcome of 0.72 (95% confidence interval = 0.49, 1.07), while those weighing 1000 through 1499 g had a relative risk of 2.02 (1.21, 2.36).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1992        PMID: 1437429

Source DB:  PubMed          Journal:  Pediatrics        ISSN: 0031-4005            Impact factor:   7.124


  3 in total

Review 1.  Umbilical artery catheters in the newborn: effects of position of the catheter tip.

Authors:  K J Barrington
Journal:  Cochrane Database Syst Rev       Date:  2000

Review 2.  Umbilical artery catheters in the newborn: effects of catheter design (end vs side hole).

Authors:  K J Barrington
Journal:  Cochrane Database Syst Rev       Date:  2000

3.  How fast is too fast? a practice change in umbilical arterial catheter blood sampling using the Iowa Model for Evidence-Based Practice.

Authors:  Myrna Gordon; Lisa Bartruff; Sara Gordon; Maria Lofgren; John A Widness
Journal:  Adv Neonatal Care       Date:  2008-08       Impact factor: 1.968

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.