Literature DB >> 10782791

Dense packing of cerebral aneurysms: an in vitro study with detachable platinum coils.

M Piotin1, S Mandai, K J Murphy, K Sugiu, P Gailloud, J B Martin, D A Rüfenacht.   

Abstract

Aneurysm models were used to study the density of packing after coil embolization. Platinum coils were introduced until the point of minimally dense packing, indicated by aneurysmal circulatory exclusion. Packing was continued up to the point of maximal density, indicated by protrusion into the parent artery. Volumetric ratios (coil volume/aneurysmal volume) were calculated for minimally and maximally dense packing. Maximally dense packing ratios were a little higher than the minimally dense ratios, but less than 37%.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10782791      PMCID: PMC7976641     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  12 in total

1.  Guglielmi detachable coil embolization of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patients.

Authors:  F Viñuela; G Duckwiler; M Mawad
Journal:  J Neurosurg       Date:  1997-03       Impact factor: 5.115

2.  Second-generation three-dimensional reconstruction for rotational three-dimensional angiography.

Authors:  L M Bidaut; C Laurent; M Piotin; P Gailloud; M Muster; J H Fasel; D A Rüfenacht; F Terrier
Journal:  Acad Radiol       Date:  1998-12       Impact factor: 3.173

3.  The nature of thrombosis induced by platinum and tungsten coils in saccular aneurysms.

Authors:  J V Byrne; J K Hope; N Hubbard; J H Morris
Journal:  AJNR Am J Neuroradiol       Date:  1997-01       Impact factor: 3.825

4.  An in vitro anatomic model of the human cerebral arteries with saccular arterial aneurysms.

Authors:  P Gailloud; J R Pray; M Muster; M Piotin; J H Fasel; D A Rüfenacht
Journal:  Surg Radiol Anat       Date:  1997       Impact factor: 1.246

5.  Scanning electron microscopic findings in a basilar tip aneurysm embolized with Guglielmi detachable coils.

Authors:  M B Horowitz; P D Purdy; D Burns; D Bellotto
Journal:  AJNR Am J Neuroradiol       Date:  1997-04       Impact factor: 3.825

6.  Endovascular coil occlusion of experimental aneurysms: partial treatment does not prevent subsequent rupture.

Authors:  J V Byrne; N Hubbard; J H Morris
Journal:  Neurol Res       Date:  1994-12       Impact factor: 2.448

7.  Treatment of experimental canine carotid aneurysms with platinum coils.

Authors:  V B Graves; C M Strother; A H Rappe
Journal:  AJNR Am J Neuroradiol       Date:  1993 Jul-Aug       Impact factor: 3.825

8.  Platinum coil coatings to increase thrombogenicity: a preliminary study in rabbits.

Authors:  A A Ahuja; R W Hergenrother; C M Strother; A A Rappe; S L Cooper; V B Graves
Journal:  AJNR Am J Neuroradiol       Date:  1993 Jul-Aug       Impact factor: 3.825

9.  Long-term histopathologic changes in canine aneurysms embolized with Guglielmi detachable coils.

Authors:  M E Mawad; J K Mawad; J Cartwright; Z Gokaslan
Journal:  AJNR Am J Neuroradiol       Date:  1995-01       Impact factor: 3.825

10.  Histological findings in giant aneurysms treated with Guglielmi detachable coils. Report of two cases with autopsy correlation.

Authors:  A J Molyneux; D W Ellison; J Morris; J V Byrne
Journal:  J Neurosurg       Date:  1995-07       Impact factor: 5.115

View more
  36 in total

1.  Spiral versus J-shaped coils for neurovascular embolisation-an in-vitro study.

Authors:  K Sugiu; K Tokunaga; S Mandai; J B Martin; B Jean; D A Rüfenacht
Journal:  Neuroradiology       Date:  2003-06-11       Impact factor: 2.804

2.  Evaluation of stent visibility by flat panel detector CT in patients treated for intracranial aneurysms.

Authors:  Frédéric Clarençon; Michel Piotin; Silvia Pistocchi; Drazenko Babic; Raphaël Blanc
Journal:  Neuroradiology       Date:  2012-02-04       Impact factor: 2.804

3.  Training in Neurovascular Intervention Usefulness of in-Vitro Model and Clinical Practice.

Authors:  K Sugiu; K Tokunaga; W Sasahara; K Watanabe; A Nishida; A Katsumata; N Kusaka; I Date; T Ohmoto; D A Rufenacht
Journal:  Interv Neuroradiol       Date:  2008-06-09       Impact factor: 1.610

4.  Current status and future prospect of endovascular neurosurgery.

Authors:  Young Il Jeon; Do Hoon Kwon
Journal:  J Korean Neurosurg Soc       Date:  2008-02-20

5.  In vitro evaluation of 2D-digital subtraction angiography versus 3D-time-of-flight in assessment of intracranial cerebral aneurysm filling after endovascular therapy.

Authors:  V Costalat; E Lebars; L Sarry; A Defasque; E Barbotte; H Brunel; G Bourbotte; A Bonafé
Journal:  AJNR Am J Neuroradiol       Date:  2006-01       Impact factor: 3.825

Review 6.  Coils in a nutshell: a review of coil physical properties.

Authors:  J B White; C G M Ken; H J Cloft; D F Kallmes
Journal:  AJNR Am J Neuroradiol       Date:  2008-04-16       Impact factor: 3.825

7.  How do coil configuration and packing density influence intra-aneurysmal hemodynamics?

Authors:  H G Morales; M Kim; E E Vivas; M-C Villa-Uriol; I Larrabide; T Sola; L Guimaraens; A F Frangi
Journal:  AJNR Am J Neuroradiol       Date:  2011-09-01       Impact factor: 3.825

8.  Endovascular management of neurovascular arterial injuries in the face and neck.

Authors:  Martin G Radvany; Philippe Gailloud
Journal:  Semin Intervent Radiol       Date:  2010-03       Impact factor: 1.513

9.  A report of the clinical use of the detach-18 mechanical detachable platinum coil in 41 patients.

Authors:  K J Murph; E Houdart; K T Szopinski; O Levrier; L Guimaraens; D Kühne; L Solymosi; N J Bartholdy; K Sugiu; D A Rüfenacht
Journal:  AJNR Am J Neuroradiol       Date:  2001-02       Impact factor: 3.825

10.  Isolated progressive visual loss after coiling of paraclinoid aneurysms.

Authors:  G W Schmidt; S F Oster; K C Golnik; L M Tumialán; V Biousse; R Turbin; C J Prestigiacomo; N R Miller
Journal:  AJNR Am J Neuroradiol       Date:  2007 Nov-Dec       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.