Literature DB >> 9862002

Second-generation three-dimensional reconstruction for rotational three-dimensional angiography.

L M Bidaut1, C Laurent, M Piotin, P Gailloud, M Muster, J H Fasel, D A Rüfenacht, F Terrier.   

Abstract

RATIONALE AND
OBJECTIVES: The purpose of this study was to assess the feasibility and accuracy of three-dimensional (3D) reconstruction techniques for digital subtraction angiography (DSA) in planning and evaluation of minimally invasive image-controlled therapy.
MATERIALS AND METHODS: Using a standard, commercially available system, the authors acquired DSA images and corrected them for inherent distortions. They designed and implemented parallel and multiresolution versions of cone-beam reconstruction techniques to reconstruct high-resolution targeted volumes in a short period of time. Testing was performed on anatomically correct, calibrated in vitro models of a cerebral aneurysm. These models were used with a pulsatile circulation circuit to allow for blood flow simulation during DSA, computed tomographic (CT) angiography, and magnetic resonance (MR) angiography image acquisitions.
RESULTS: The multiresolution DSA-based reconstruction protocol and its implementation allowed the authors to achieve reconstruction times and levels of accuracy for the volume measurement of the aneurysmal cavities that were considered compatible with actual clinical practice. Comparison with data obtained from other imaging modalities shows that, besides vascular tree depiction, the DSA-based true 3D technique provides volume estimates at least as good as those obtained from CT and MR angiography.
CONCLUSION: The authors demonstrated the feasibility and potential of true 3D reconstruction for angiographic imaging with DSA. On the basis of the model testing, this work addresses both the timing and quantification required to support minimally invasive image-controlled therapy.

Entities:  

Mesh:

Year:  1998        PMID: 9862002     DOI: 10.1016/s1076-6332(98)80244-4

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  20 in total

1.  Region-of-interest cone beam computed tomography (ROI CBCT) with a high resolution CMOS detector.

Authors:  A Jain; H Takemoto; M D Silver; S V S Nagesh; C N Ionita; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-18

2.  Evaluation of an improved technique for lumen path definition and lumen segmentation of atherosclerotic vessels in CT angiography.

Authors:  Evert F S van Velsen; Wiro J Niessen; Thomas T de Weert; Cécile de Monyé; Aad van der Lugt; Erik Meijering; Rik Stokking
Journal:  Eur Radiol       Date:  2006-11-01       Impact factor: 5.315

3.  In vitro evaluation of 2D-digital subtraction angiography versus 3D-time-of-flight in assessment of intracranial cerebral aneurysm filling after endovascular therapy.

Authors:  V Costalat; E Lebars; L Sarry; A Defasque; E Barbotte; H Brunel; G Bourbotte; A Bonafé
Journal:  AJNR Am J Neuroradiol       Date:  2006-01       Impact factor: 3.825

4.  Volume-of-change cone-beam CT for image-guided surgery.

Authors:  Junghoon Lee; J Webster Stayman; Yoshito Otake; Sebastian Schafer; Wojciech Zbijewski; A Jay Khanna; Jerry L Prince; Jeffrey H Siewerdsen
Journal:  Phys Med Biol       Date:  2012-07-17       Impact factor: 3.609

5.  Detection and characterization of intracranial aneurysms with 16-channel multidetector row CT angiography: a prospective comparison of volume-rendered images and digital subtraction angiography.

Authors:  D Y Yoon; K J Lim; C S Choi; B M Cho; S M Oh; S K Chang
Journal:  AJNR Am J Neuroradiol       Date:  2007-01       Impact factor: 3.825

6.  Dense packing of cerebral aneurysms: an in vitro study with detachable platinum coils.

Authors:  M Piotin; S Mandai; K J Murphy; K Sugiu; P Gailloud; J B Martin; D A Rüfenacht
Journal:  AJNR Am J Neuroradiol       Date:  2000-04       Impact factor: 3.825

7.  Anatomic features predictive of complete aneurysm occlusion can be determined with three-dimensional digital subtraction angiography.

Authors:  Hiro Kiyosue; Shuichi Tanoue; Mika Okahara; Yuzo Hori; Takaharu Nakamura; Hirofumi Nagatomi; Hiromu Mori
Journal:  AJNR Am J Neuroradiol       Date:  2002-08       Impact factor: 3.825

8.  Comparison of three-dimensional rotational angiography with digital subtraction angiography in the assessment of ruptured cerebral aneurysms.

Authors:  Albrecht Hochmuth; Uwe Spetzger; Martin Schumacher
Journal:  AJNR Am J Neuroradiol       Date:  2002-08       Impact factor: 3.825

9.  3D rotational digital subtraction angiography may underestimate intracranial aneurysms: findings from two basilar aneurysms.

Authors:  L-D Jou; A Mohamed; D H Lee; M E Mawad
Journal:  AJNR Am J Neuroradiol       Date:  2007-09-24       Impact factor: 3.825

10.  Influence of geometric and hemodynamic parameters on aneurysm visualization during three-dimensional rotational angiography: an in vitro study.

Authors:  Ulrike U Ernemann; Eckart Grönewäller; Frank B Duffner; Oezlem Guervit; Joerg Claassen; Martin D Skalej
Journal:  AJNR Am J Neuroradiol       Date:  2003-04       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.