Literature DB >> 25850981

Multi-patient finite element simulation of keeled versus pegged glenoid implant designs in shoulder arthroplasty.

Werner Pomwenger1, Karl Entacher2, Herbert Resch3, Peter Schuller-Götzburg4.   

Abstract

This study investigates the mechanical behaviour of keeled and pegged implant designs used in shoulder arthroplasty for the first time using multiple 3D models. Thus, this study should provide valuable insights into the preferable use of either of these two controversial implant designs. Three-dimensional models of a scapula were derived from the CT scans of five patients, and an inter-patient-specific finite element analysis with special attention to bone density and boundary conditions was carried out. A distinct decrease in the investigated parameters was evident with the pegged implant in all of the patients, specifically for the implant and the bone cement. The relevance of the stress reduction within the bone is minor, whereas the reduction in the stress of the bone cement contributes to an increase in the bone cement survival. The particular construction of the pegged implant provides better stability and therefore supports bone ingrowth. The large variations between the patients show the necessity of patient-specific simulations and the use of multiple models to derive valuable results. In the conducted inter-patient-specific FEA, the pegged glenoid implants were found to exhibit superior behaviour compared with keeled implants. The results confirm the general clinical findings and demonstrate the FEA as a valuable tool in prosthetic and orthopaedic problems.

Entities:  

Keywords:  3D modelling; Boundary conditions; Finite element analysis; Glenoid implant; Micromotions

Mesh:

Year:  2015        PMID: 25850981     DOI: 10.1007/s11517-015-1286-7

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  39 in total

1.  The fixation of the cemented femoral component. Effects of stem stiffness, cement thickness and roughness of the cement-bone surface.

Authors:  N A Ramaniraka; L R Rakotomanana; P F Leyvraz
Journal:  J Bone Joint Surg Br       Date:  2000-03

2.  Extracting clinically relevant data from finite element simulations.

Authors:  Marco Viceconti; Sigbjorn Olsen; Lutz-P Nolte; Kim Burton
Journal:  Clin Biomech (Bristol, Avon)       Date:  2005-06       Impact factor: 2.063

3.  Influence of glenohumeral conformity on glenoid stresses after total shoulder arthroplasty.

Authors:  Alexandre Terrier; Philippe Büchler; Alain Farron
Journal:  J Shoulder Elbow Surg       Date:  2006 Jul-Aug       Impact factor: 3.019

4.  Evaluation of the glenoid implant survival using a biomechanical finite element analysis: influence of the implant design, bone properties, and loading location.

Authors:  P Mansat; J Briot; M Mansat; P Swider
Journal:  J Shoulder Elbow Surg       Date:  2006-08-07       Impact factor: 3.019

5.  Microstimulation at the bone-implant interface upregulates osteoclast activation pathways.

Authors:  Vincent A Stadelmann; Alexandre Terrier; Dominique P Pioletti
Journal:  Bone       Date:  2007-10-05       Impact factor: 4.398

6.  Complications in shoulder arthroplasty: an analysis of 485 cases.

Authors:  Peter R Aldinger; Patric Raiss; Markus Rickert; Markus Loew
Journal:  Int Orthop       Date:  2009-04-28       Impact factor: 3.075

7.  Complications of total shoulder arthroplasty: are they fewer or different?

Authors:  Patrick Y K Chin; John W Sperling; Robert H Cofield; Cathy Schleck
Journal:  J Shoulder Elbow Surg       Date:  2006 Jan-Feb       Impact factor: 3.019

8.  Mechanical properties of glenoid cancellous bone.

Authors:  Ibrahim Kalouche; Jérôme Crépin; Samir Abdelmoumen; David Mitton; Geneviève Guillot; Olivier Gagey
Journal:  Clin Biomech (Bristol, Avon)       Date:  2010-01-18       Impact factor: 2.063

9.  Glenohumeral kinematics following total shoulder arthroplasty: a finite element investigation.

Authors:  Andrew R Hopkins; Ulrich N Hansen; Andrew A Amis; Mark Taylor; Roger J Emery
Journal:  J Orthop Res       Date:  2007-01       Impact factor: 3.494

10.  Shoulder arthroplasty in patients aged fifty-five years or younger with osteoarthritis.

Authors:  Robert Bartelt; John W Sperling; Cathy D Schleck; Robert H Cofield
Journal:  J Shoulder Elbow Surg       Date:  2010-08-25       Impact factor: 3.019

View more
  2 in total

1.  Fast in silico assessment of physical stress for peripheral nerves.

Authors:  Elisabetta Giannessi; Maria Rita Stornelli; Pier Nicola Sergi
Journal:  Med Biol Eng Comput       Date:  2018-02-12       Impact factor: 2.602

2.  Number of pegs influence focal stress distributions and micromotion in glenoid implants: a finite element study.

Authors:  Abdul Hadi Abdul Wahab; Mohammed Rafiq Abdul Kadir; Muhammad Noor Harun; Tunku Kamarul; Ardiyansyah Syahrom
Journal:  Med Biol Eng Comput       Date:  2016-06-02       Impact factor: 2.602

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.